Diagnosis of Postoperative Urinary Retention Using a Simplified Ultrasound Bladder Measurement

被引:30
作者
Daurat, Aurelien [1 ]
Choquet, Olivier [1 ]
Bringuier, Sophie [1 ,2 ]
Charbit, Jonathan [1 ]
Egan, Michael [1 ]
Capdevila, Xavier [1 ]
机构
[1] Lapeyronie Univ Hosp, Dept Anesthesia & Crit Care Med, F-34090 Montpellier, France
[2] Lapeyronie Univ Hosp, Dept Biostat, F-34090 Montpellier, France
关键词
VOLUME; ACCURACY; DEVICE;
D O I
10.1213/ANE.0000000000000595
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: In this study, we sought to determine whether a simplified ultrasound measurement of the largest transverse diameter, using a standard ultrasound machine, could be used to diagnose postoperative urinary retention (POUR). This method may replace expensive bladder volume measuring devices or a more complex ultrasound procedure (involving the measurement of 3 bladder diameters). METHODS: Patients at risk of POUR if unable to void after orthopedic surgery were evaluated in the postanesthesia care unit before discharge. Bladder diameter was first measured using a portable ultrasound device (Vscan (R); GE Healthcare, Wauwatosa, WI). An automated evaluation of bladder volume was then performed (Bladderscan (R) BVI 3000; Diagnostic Ultrasound, Redmond, WA). Finally, when a bladder catheterization was performed, the actual urinary volume was measured. The main outcome was a bladder volume >= 600 mL as measured using the automated ultrasound scanner (Bladderscan BVI 3000) or by catheterization. Correlations between bladder volumes and diameter were studied and receiver operating characteristic curves were constructed to determine the performance in predicting a bladder volume >= 600 mL. A "gray zone" approach was developed because a single cutoff value may not always be clinically significant. RESULTS: One hundred patients were included and underwent a Bladderscan measurement. Urinary volume after catheterization was obtained in 49 patients. A significant correlation was found between the largest transverse diameter and urinary volumes assessed by the 2 methods (Bladderscan and catheterization). Pearson correlation coefficients were r = 0.80 (95% confidence interval [CI], 0.72-0.86; P < 0.001) and r = 0.79 (95% CI, 0.65-0.88; P < 0.001), respectively. The area under the receiver operating characteristic curves for the prediction of a bladder volume = 600 mL were 0.94 (95% CI, 0.88-0.98) and 0.91 (95% CI, 0.79-0.97), respectively, for urinary volumes assessed by Bladderscan and catheterization. The optimal cutoff value was 9.7 cm for both methods. The gray zone was narrow, ranging from 9.7 to 10.7 cm thus limiting inconclusive measurements. CONCLUSIONS: A simple ultrasound measurement of the largest transverse bladder diameter seemed to be helpful to exclude or confirm POUR.
引用
收藏
页码:1033 / 1038
页数:6
相关论文
共 20 条
  • [1] Balderi T, 2011, MINERVA ANESTESIOL, V77, P1050
  • [2] Postoperative Urinary Retention Anesthetic and Perioperative Considerations
    Baldini, Gabriele
    Bagry, Hema
    Aprikian, Armen
    Carli, Franco
    [J]. ANESTHESIOLOGY, 2009, 110 (05) : 1139 - 1157
  • [3] Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach
    Cannesson, Maxime
    Le Manach, Yannick
    Hofer, Christoph K.
    Goarin, Jean Pierre
    Lehot, Jean-Jacques
    Vallet, Benoit
    Tavernier, Benoit
    [J]. ANESTHESIOLOGY, 2011, 115 (02) : 231 - 241
  • [4] Fast Track Echo of Abdominal Aortic Aneurysm Using a Real Pocket-Ultrasound Device at Bedside
    Dijos, Marina
    Pucheux, Yann
    Lafitte, Marianne
    Reant, Patricia
    Prevot, Alain
    Mignot, Aude
    Barandon, Laurent
    Roques, Xavier
    Roudaut, Raymond
    Pilois, Xavier
    Lafitte, Stephane
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (03): : 285 - 290
  • [5] Clinical agreement between automated and calculated ultrasound measurements of bladder volume
    Dudley, NJ
    Kirkland, M
    Lovett, J
    Watson, AR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (911) : 832 - 834
  • [6] New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners
    Frederiksen, C. A.
    Juhl-Olsen, P.
    Larsen, U. T.
    Nielsen, D. G.
    Eika, B.
    Sloth, E.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (10) : 1217 - 1223
  • [7] Griesdale DEG, 2011, CAN J ANESTH, V58, P1097, DOI 10.1007/s12630-011-9595-2
  • [8] Novel algorithm for improving accuracy of ultrasound measurement of residual urine volume according to bladder shape
    Hwang, JY
    Byun, SS
    Oh, SJ
    Kim, HC
    [J]. UROLOGY, 2004, 64 (05) : 887 - 891
  • [9] Predictive factors of early postoperative urinary retention in the postanesthesia care unit
    Keita, H
    Diouf, E
    Tubach, F
    Brouwer, T
    Dahmani, S
    Mantz, J
    Desmonts, JM
    [J]. ANESTHESIA AND ANALGESIA, 2005, 101 (02) : 592 - 596
  • [10] McGraw KO, 1996, PSYCHOL METHODS, V1, P30, DOI 10.1037/1082-989X.1.4.390