Multiple pH measurement during storage may detect bacterially contaminated platelet concentrates

被引:10
作者
Barker, Lynn M.
Nanassy, Oliver Z.
Reed, Michael W.
Geelhood, Steven J.
Pfalzgraf, Randy D.
Cangelosi, Gerard A.
de Korte, Dirk [1 ]
机构
[1] Sanquin Res, Sanquin Blood Supply Fdn, Blood Cell Res, NL-1066 CX Amsterdam, Netherlands
关键词
SAFETY; RISK; DISINFECTION; DIVERSION; QUALITY; MARKERS; VOLUME;
D O I
10.1111/j.1537-2995.2010.02727.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Bacterial contamination or platelet (PLT) metabolism can change the pH of stored PLT concentrates (PCs). Measurement of pH for quality control is currently done on a limited basis. An easy noninvasive method was developed to obtain sequential pH measurements over time, without risking contamination and/or consuming PCs. STUDY DESIGN AND METHODS: The objective was to measure pH profiles of bacterially contaminated PCs over 7 days of storage. Small-volume PC storage bags with incorporated pH sensor were prepared and in vitro variables were tested using aliquots of PCs. The pH sensors were used to delineate trends associated with the deterioration of these PCs upon inoculation with 19 different bacterial strains and one yeast. RESULTS: Monitoring the pH trends in real time in a noninvasive fashion, most bacterial strains were detected within 24 to 72 hours after spiking into the bag. At the time of detection, bacterial concentrations had reached levels between 1 x 103 and 1 x 108 colony-forming units/mL. Several strains had pH rebound after initial drop. Multiple noninvasive pH reads allowed bacterial detection whereas single pH reads could give false-negative results. CONCLUSIONS: The noninvasive pH sensor facilitated the detection of most strains of bacterial contaminants within 3 days with no potential for sampling error.
引用
收藏
页码:2731 / 2737
页数:7
相关论文
共 19 条
[1]  
ASHWOOD ER, 1983, CLIN CHEM, V29, P1877
[2]   The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates [J].
Benjamin, Richard J. ;
Wagner, Stephen J. .
TRANSFUSION, 2007, 47 (08) :1381-1389
[3]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[4]   Rapid identification of bacterially contaminated platelets using reagent strips: Glucose and pH analysis as markers of bacterial metabolism [J].
Burstain, JM ;
Brecher, ME ;
Workman, K ;
Foster, M ;
Faber, GH ;
Mair, D .
TRANSFUSION, 1997, 37 (03) :255-258
[5]   Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands [J].
de Korte, D ;
Curvers, J ;
de Kort, WLAM ;
Hoekstra, T ;
van der Poel, CL ;
Beckers, EAM ;
Marcelis, JH .
TRANSFUSION, 2006, 46 (03) :476-485
[6]   Limiting and detecting bacterial contamination of apheresis platelets: inlet-line diversion and increased culture volume improve component safety [J].
Eder, Anne F. ;
Kennedy, Jean M. ;
Dy, Beth A. ;
Notari, Edward P. ;
Skeate, Robert ;
Bachowski, Gary ;
Mair, David C. ;
Webb, Jonathan S. ;
Wagner, Stephen J. ;
Dodd, Roger Y. ;
Benjamin, Richard J. .
TRANSFUSION, 2009, 49 (08) :1554-1563
[7]   Bacterial culture reduces but does not eliminate the risk of septic transfusion reactions to single-donor platelets [J].
Fuller, Alice K. ;
Uglik, Kristin M. ;
Savage, William J. ;
Ness, Paul M. ;
King, Karen E. .
TRANSFUSION, 2009, 49 (12) :2588-2593
[8]   Storage and quality assessment of platelets [J].
Holme, S .
VOX SANGUINIS, 1998, 74 :207-214
[9]   The impact of discontinuation of 7-day storage of apheresis platelets (PASSPORT) on recipient safety: an illustration of the need for proper risk assessments [J].
Kleinman, Steven ;
Dumont, Larry J. ;
Tomasulo, Peter ;
Bianco, Celso ;
Katz, Louis ;
Benjamin, Richard J. ;
Gajic, Ognjen ;
Brecher, Mark E. .
TRANSFUSION, 2009, 49 (05) :903-912
[10]   Bacterial screening of platelet concentrates: results of 2 years active surveillance of transfused positive cultured units released as negative to date [J].
Koopman, M. M. W. ;
van't Ende, E. ;
Lieshout-Krikke, R. ;
Marcelis, J. ;
Smid, W. M. ;
de Korte, D. .
VOX SANGUINIS, 2009, 97 (04) :355-357