PurposeThere is great potential for real-time investigation of metabolism with MRS and hyperpolarized (HP) C-13 agents. Unfortunately, HP technology has high associated costs and efficiency limitations that may constrain in vivo studies involving many animals. To improve the throughput of preclinical investigations, we evaluate the feasibility of performing HP MRS on multiple animals simultaneously. MethodsSimulations helped assess the viability of a dual-coil strategy for spatially localized multivolume MRS. A dual-mouse system was assembled and characterized with bench- and scanner-based experiments. Enzyme phantoms mixed with HP [1-C-13] pyruvate emulated real-time metabolism and offered a controlled mechanism for evaluating system performance. Finally, a normal mouse and a mouse bearing a subcutaneous xenograft of colon cancer were simultaneously scanned in vivo using an agent containing HP [1-C-13] pyruvate. ResultsGeometric separation/rotation, active decoupling, and use of low input impedance preamplifiers permitted an encode-by-channel approach for spatially localized MRS. A precalibrated shim allowed straightforward metabolite differentiation in enzyme phantom and in vivo experiments at 7 Tesla, with performance similar to conventional acquisitions. ConclusionThe initial feasibility of multi-animal HP C-13 MRS was established. Throughput scales with the number of simultaneously scanned animals, demonstrating the potential for significant improvements in study efficiency. Magn Reson Med 73:1726-1732, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1726 / 1732
页数:7
相关论文
共 35 条
  • [1] Hyperpolarized 13C Lactate, Pyruvate, and Alanine: Noninvasive Biomarkers for Prostate Cancer Detection and Grading
    Albers, Mark J.
    Bok, Robert
    Chen, Albert P.
    Cunningham, Charles H.
    Zierhut, Matt L.
    Zhang, Vickie Yi
    Kohler, Susan J.
    Tropp, James
    Hurd, Ralph E.
    Yen, Yi-Fen
    Nelson, Sarah J.
    Vigneron, Daniel B.
    Kurhanewicz, John
    [J]. CANCER RESEARCH, 2008, 68 (20) : 8607 - 8615
  • [2] Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR
    Ardenkjaer-Larsen, JH
    Fridlund, B
    Gram, A
    Hansson, G
    Hansson, L
    Lerche, MH
    Servin, R
    Thaning, M
    Golman, K
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) : 10158 - 10163
  • [3] Bernardo M, 2011, P 19 ANN M ISMRM MON
  • [4] Bernardo M, 2003, P 14 ANN M ISMRM SEA
  • [5] Small-animal MRI: signal-to-noise ratio comparison at 7 and 1.5 T with multiple-animal acquisition strategies
    Beuf, Olivier
    Jaillon, Franck
    Saint-Jalmes, Herve
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (04) : 202 - 208
  • [6] Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
  • [7] In vivo multiple-mouse MRI at 7 Tesla
    Bock, NA
    Nieman, BJ
    Bishop, JB
    Henkelman, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1311 - 1316
  • [8] High-resolution longitudinal screening with magnetic resonance imaging in a murine brain cancer model
    Bock, NA
    Zadeh, G
    Davidson, LM
    Qian, BP
    Sled, JG
    Guha, A
    Henkelman, RM
    [J]. NEOPLASIA, 2003, 5 (06): : 546 - 554
  • [9] Multiple-mouse MRI
    Bock, NA
    Konyer, NB
    Henkelman, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 158 - 167
  • [10] PARA-HYDROGEN AND SYNTHESIS ALLOW DRAMATICALLY ENHANCED NUCLEAR ALIGNMENT
    BOWERS, CR
    WEITEKAMP, DP
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1987, 109 (18) : 5541 - 5542