Inaccuracies in the Use of Magnification Markers in Digital Hip Radiographs

被引:40
作者
Archibeck, Michael J. [1 ]
Cummins, Tamara [1 ]
Tripuraneni, Krishna R. [1 ]
Carothers, Joshua T. [1 ]
Murray-Krezan, Cristina [2 ]
Hattab, Mohammad [3 ]
White, Richard E., Jr. [1 ]
机构
[1] New Mexico Orthopaed, 201 Cedar SE,Suite 6600, Albuquerque, NM 87106 USA
[2] Univ New Mexico, Hlth Sci Ctr, Dept Internal Med, Div Epidemiol Biostat & Prevent Med, Albuquerque, NM 87131 USA
[3] Univ New Mexico, Dept Math & Stat, Albuquerque, NM 87131 USA
关键词
ARTHROPLASTY; ACCURACY;
D O I
10.1007/s11999-016-4704-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
With the ubiquity of digital radiographs, the use of digital templating for arthroplasty has become commonplace. Although improved accuracy with digital radiographs and magnification markers is assumed, it has not been shown. We wanted to (1) evaluate the accuracy of magnification markers in estimating the magnification of the true hip and (2) determine if the use of magnification markers improves on older techniques of assuming a magnification of 20% for all patients. Between April 2013 and September 2013 we collected 100 AP pelvis radiographs of patients who had a THA prosthesis in situ and a magnification marker placed per the manufacturer's instructions. Radiographs seen during our standard radiographic review process, which met our inclusion criteria (AP pelvic view that included a well-positioned and observed magnification marker, and a prior total hip replacement with a known femoral head size), were included in the analysis. We then used OrthoView(TM) software program to calculate magnification of the radiograph using the magnification marker (measured magnification) and the femoral head of known size (true magnification). The mean true magnification using the femoral head was 21% (SD, 2%). The mean magnification using the marker was 15% (SD, 5%). The 95% CI for the mean difference between the two measurements was 6% to 7% (p < 0.001). The use of a magnification marker to estimate magnification at the level of the hip using standard radiographic techniques was shown in this study to routinely underestimate the magnification of the radiograph using an arthroplasty femoral head of known diameter as the reference. If we assume a magnification of 20%, this more closely approximated the true magnification routinely. With this assumption, we were within 2% magnification in 64 of the 100 hips and off by 4% or more in only four hips. In contrast, using the magnification marker we were within 2% of true magnification in only 20 hips and were off by 4% or more in 59 hips. We found the use of a magnification marker with digital radiographs for preoperative templating to be generally inaccurate, with a mean error of 6% and range from -5% to 15%. Additionally, these data suggest that the use of a magnification marker while taking preoperative radiographs of the hip may be unnecessary, as simply setting the software to assume a 20% magnification actually was more accurate. Level III, diagnostic study.
引用
收藏
页码:1812 / 1817
页数:6
相关论文
共 8 条
[1]   The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty [J].
Gamble, Patrick ;
de Beer, Justin ;
Petruccelli, Danielle ;
Winemaker, Mitchell .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :529-532
[2]   A Comparison of Acetate vs Digital Templating for Preoperative Planning of Total Hip Arthroplasty [J].
Iorio, Richard ;
Siegel, Jodi ;
Specht, Lawrence M. ;
Tilzey, John F. ;
Hartman, Audrey ;
Healy, William L. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (02) :175-179
[3]   Accuracy of Digital Preoperative Templating in 100 Consecutive Uncemented Total Hip Arthroplasties A Single Surgeon Series [J].
Shaarani, Shahril R. ;
McHugh, Gavin ;
Collins, Denis A. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (02) :331-337
[4]   Assessment of Accuracy of Marker Ball Placement in Pre-operative Templating for Total Hip Arthroplasty [J].
Sinclair, Victoria F. ;
Wilson, James ;
Jain, Neil P. M. ;
Knowles, David .
JOURNAL OF ARTHROPLASTY, 2014, 29 (08) :1658-1660
[5]   ESTIMATION OF THE INTRACLASS CORRELATION-COEFFICIENT FOR THE ANALYSIS OF COVARIANCE MODEL [J].
STANISH, WM ;
TAYLOR, N .
AMERICAN STATISTICIAN, 1983, 37 (03) :221-224
[6]   Preoperative planning of total hip replacement using the TraumaCad™ system [J].
Steinberg, Ely Liviu ;
Shasha, Nadav ;
Menahem, Aharon ;
Dekel, Shmuel .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (12) :1429-1432
[7]  
Whiddon David R, 2011, Am J Orthop (Belle Mead NJ), V40, P395
[8]  
Whiddon David R, 2008, Instr Course Lect, V57, P273