Biomechanical Evaluation of Acetabular Cup Implantation in Cementless Total Hip Arthroplasty

被引:11
作者
Margalit, Kate A. [2 ]
Hayashi, Kei [1 ]
Jackson, Josh [2 ]
Kim, Sun Young
Garcia, Tanya C.
Wiggans, K. Tomo
Aiken, Sean [2 ]
Stover, Susan M.
机构
[1] Univ Calif Davis, Dept Surg & Radiol Sci, JD Wheat Vet Orthoped Res Lab, Davis, CA 95616 USA
[2] Vet Specialty Hosp, San Diego, CA USA
关键词
INGROWTH ANALYSIS; CANINE MODEL; COMPONENT; FRACTURE; DOGS; FIXATION; AUGMENTATION; REPLACEMENTS; PROSTHESIS; FORCES;
D O I
10.1111/j.1532-950X.2010.00726.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To report biomechanical properties of the Biologic Fixation System (BFX) acetabular cup impacted into a normal canine pelvis and to compare the effect of implant positioned to and beyond the medial acetabular wall. Study Design In vitro cadaveric study. Animals Hemipelves of mature, large-breed dogs (n=6). Methods For each dog, 1 hemipelvis was reamed to the depth of the acetabular wall (group A) and 1 was reamed an additional 6 mm after penetration of the medial cortex of the acetabulum (group B). The hemipelves were implanted with acetabular cups and loaded in compression through a matching femoral prosthetic component until failure. Specimen stiffness, and failure displacement, load, and energy were determined from load and displacement data and results between groups compared with a paired t-test. Results Mean failure load was greater in group A (3812 +/- 391 N) than group B (2924 +/- 316 N; P <.014). No other differences (P >.05) were observed between groups. Bone fracture (n=5) and cup displacement (1) occurred in group A whereas in group B there were 3 fractures and 3 cup displacements. Conclusions Although medial placement of the BFX cup affected compressive failure loads, failure loads for both groups exceeded normal physiologic loads. Clinical Relevance Medial positioning of the acetabular cup does not appear to compromise acetabular implant-pelvic stability under normal physiologic loads. Because arthroplasty candidates often have abnormal acetabular architecture, mechanical properties of the cup placed in acetabula without a dorsal rim should be investigated.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 23 条
[1]   A COMPARISON OF HIP-JOINT FORCES IN SHEEP, DOG AND MAN [J].
BERGMANN, G ;
SIRAKY, J ;
ROHLMANN, A ;
KOELBEL, R .
JOURNAL OF BIOMECHANICS, 1984, 17 (12) :907-&
[2]  
*BIOMEDTRIX INC, CAN MOD TOT HIP REPL
[3]  
CHEN PQ, 1983, CLIN ORTHOP RELAT R, P24
[4]   IMPLANTATION OF AN UNCEMENTED TOTAL HIP-PROSTHESIS - TECHNIQUE AND INITIAL RESULTS OF 100 ARTHROPLASTIES [J].
DEYOUNG, DJ ;
DEYOUNG, BA ;
ABERMAN, HA ;
KENNA, RV ;
HUNGERFORD, DS .
VETERINARY SURGERY, 1992, 21 (03) :168-177
[5]   Evaluation of risk factors for luxation after total hip replacement in dogs [J].
Dyce, J ;
Wisner, ER ;
Wang, Q ;
Olmstead, ML .
VETERINARY SURGERY, 2000, 29 (06) :524-532
[6]  
El-Warrak AO, 2001, VET COMP ORTHOPAED, V14, P115
[7]   Zurich Cementless Total Hip Replacement: Retrospective Evaluation of 2nd Generation Implants in 60 Dogs [J].
Guerrero, Tomas G. ;
Montavon, Pierre M. .
VETERINARY SURGERY, 2009, 38 (01) :70-80
[8]   Radiographic evaluation of the zurich cementless total hip acetabular component [J].
Hanson, Steven P. ;
Peck, Jeffrey N. ;
Berry, Clifford R. ;
Graham, John ;
Stevens, Gary .
VETERINARY SURGERY, 2006, 35 (06) :550-558
[9]   Biomechanical comparison of two plating techniques for fixation of acetabular osteotomies in dogs [J].
Hardie, RJ ;
Bertram, JEA ;
TodHunter, RJ ;
Trotter, EJ .
VETERINARY SURGERY, 1999, 28 (03) :148-153
[10]  
HEDLEY AK, 1983, CLIN ORTHOP RELAT R, P12