Cyclodextrin-modified monolithic columns for resolving dansyl amino acid enantiomers and positional isomers by capillary electrochromatography

被引:61
|
作者
Chen, ZL
Ozawa, H
Uchiyama, K
Hobo, T
机构
[1] NTT Corp, Microsyst Integrat Labs, Ubiquitous Interface Lab, Biosensing Res Grp, Kanagawa 2430198, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Engn, Dept Appl Chem, Tokyo 158, Japan
关键词
capillary electrochromatography; chiral separation; cyclodextrin; dansyl amino acids; monolithic column; positional isomers; sol-gel process;
D O I
10.1002/elps.200305403
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 gm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mm 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-Enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.
引用
收藏
页码:2550 / 2558
页数:9
相关论文
共 45 条
  • [31] Benzoic acid-modified monolithic column for separation of hydrophilic compounds by capillary electrochromatography with high content of water in mobile phase
    Hu, Changjun
    Mao, Zhenkun
    Li, Zhentao
    Li, Qiaoyan
    Chen, Zilin
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1647
  • [32] Preparation of a zeolite imidazole skeleton-silica hybrid monolithic column for amino acid analysis via capillary electrochromatography
    Qin, Shili
    Cui, Hongshou
    Chu, Hongtao
    Gao, Lidi
    Li, Xue
    Tang, Yimin
    You, Xingyu
    Dong, Qing
    ELECTROPHORESIS, 2022, 43 (16-17) : 1710 - 1723
  • [33] Influence of the amino acid sequence and nature of the cyclodextrin on the separation of small peptide enantiomers by capillary electrophoresis using α-, β-, and γ-cyclodextrin and the corresponding hydroxypropyl derivatives
    Sidamonidze, N
    Süss, F
    Poppitz, W
    Scriba, GKE
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (09) : 777 - 783
  • [34] Separation of dipeptide and tripeptide enantiomers in capillary electrophoresis using carboxymethyl-β-cyclodextrin and succinyl-β-cyclodextrin:: Influence of the amino acid sequence, nature of the cyclodextrin and pH
    Sabbah, S
    Scriba, GKE
    ELECTROPHORESIS, 2001, 22 (07) : 1385 - 1393
  • [35] Rapid determination of aristolochic acid I and II in Aristolochia plants from different regions by β-cyclodextrin-modified capillary zone electrophoresis
    Li, W
    Gong, SX
    Wen, DW
    Che, BQ
    Liao, YP
    Liu, HW
    Feng, XF
    Hu, SL
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1049 (1-2) : 211 - 217
  • [36] An organic polymer monolith modified with an amino acid ionic liquid and graphene oxide for use in capillary electrochromatography: application to the separation of amino acids, β-blockers, and nucleotides
    Shiyuan Zhao
    Tao Yu
    Yingxiang Du
    Xiaodong Sun
    Zijie Feng
    Xiaofei Ma
    Wen Ding
    Cheng Chen
    Microchimica Acta, 2019, 186
  • [37] An organic polymer monolith modified with an amino acid ionic liquid and graphene oxide for use in capillary electrochromatography: application to the separation of amino acids, β-blockers, and nucleotides
    Zhao, Shiyuan
    Yu, Tao
    Du, Yingxiang
    Sun, Xiaodong
    Feng, Zijie
    Ma, Xiaofei
    Ding, Wen
    Chen, Cheng
    MICROCHIMICA ACTA, 2019, 186 (09)
  • [38] Poly(glyceryl monomethacrylate-co-ethylene glycol dimethacrylate) monolithic columns with incorporated bare and surface modified gluconamide fumed silica nanoparticles for hydrophilic interaction capillary electrochromatography
    Ganewatta, Nisansala
    El Rassi, Ziad
    TALANTA, 2018, 179 : 632 - 640
  • [39] Influence of the amino acid sequence and nature of the cyclodextrin on the separation of small peptide enantiomers by capillary electrophoresis using randomly substituted and single isomer sulfated and sulfonated cyclodextrins
    Süss, F
    Poppitz, W
    Sänger-van de Griend, CE
    Scriba, GKE
    ELECTROPHORESIS, 2001, 22 (12) : 2416 - 2423
  • [40] A monolithic capillary modified with a copoplymer prepared from the ionic liquid 1-vinyl-3-octylimidazolium bromide and styrene for electrochromatography of alkylbenzenes, polycyclic aromatic hydrocarbons, proteins and amino acids
    Ying Xi
    Yingxiang Du
    Xiaodong Sun
    Shiyuan Zhao
    Zijie Feng
    Cheng Chen
    Wen Ding
    Microchimica Acta, 2020, 187