Theoretical and experimental analysis of overall cooling effectiveness for afterburner double-wall heat shield

被引:15
作者
Niu, Jia-jia [1 ,2 ]
Liu, Cun-liang [1 ,2 ]
Liu, Hai-yong [1 ,2 ]
Xiao, Xiang [3 ]
Lin, Jian-fu [3 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Shaanxi, Peoples R China
[2] Shaanxi Key Lab Thermal Sci Aeroengine Syst, Xian 710072, Peoples R China
[3] AECC Sichuan Gas Turbine Estab, Chengdu 610500, Peoples R China
关键词
Afterburner heat shield; Impingement/effusion cooling; Analogy theory; Open area; Mainstream Reynolds number; Overall cooling effectiveness; CROSS-FLOW; STAGGERED ARRAYS; EFFUSION PLATE; CIRCULAR JETS; IN-LINE; FILM; IMPINGEMENT;
D O I
10.1016/j.ijheatmasstransfer.2021.121360
中图分类号
O414.1 [热力学];
学科分类号
摘要
The porous heat shield installed in the afterburner can effectively prevent the afterburner cylinder from overheating. Impingement/effusion cooling is one composite cooling technique to effectively improve the overall cooling effectiveness of the heat shield. Designing effective and efficient double-wall configurations requires a detailed understanding of how geometry and operating conditions affect the way coolant cools the afterburner cylinder. In this study, conjugated heat transfer experiments were conducted using IR thermography for double-wall heat shields with three open areas of the impingement plate (sigma = 0.5%, 0.7%, 0.8%). The momentum flux ratio was varied in the range 0.01 <= 1 <= 0.50. The mainstream Reynolds number, based on the diameter of the film hole, was varied in the range 800 <= Re-g <= 2000. The effects of geometrical and aerodynamic parameters on overall cooling effectiveness were experimentally and numerically investigated with the comprehensive effects of solid heat conduction and convection heat transfer. The experiments were modeled in a low-temperature state (T-g = 603 K, = 298 K), which was based on the analogy theory and matching principle, as if the experiments were conducted under engine operating conditions. The modeling accuracy of experimental results was analyzed by the analogy theory. Results show that the difference in the overall cooling effectiveness between "laboratory" conditions (T-g/T-c = 2) and "engine" conditions (T-g/T-c = 4) is within 0.048. The overall cooling effectiveness is mainly affected by the open area through adiabatic cooling effectiveness and internal heat transfer, and that is mainly affected by the mainstream Reynolds number through external heat transfer. According to the area-averaged results in given experimental conditions, the maximum overall cooling effectiveness raise and drop coefficients after increasing open area and mainstream Reynolds number are 17.3% and 6%, respectively. Thus, the high open area and low mainstream Reynolds number are beneficial to improve the overall cooling effectiveness of the afterburner double-wall heat shield. Furthermore, the experimental measurements provide an important database for the evaluation of computational fluid dynamics simulations of the conjugate heat transfer effects occurring in the double-wall heat shield. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:18
相关论文
共 41 条
  • [1] Albert J.E., 2011, P ASME TURB EXP ASME
  • [2] Albert J.E., 2004, P ASME TURB EXP ASME
  • [3] Ammari H.D., 1989, GAS TURB AER ENG C E
  • [4] Experimental and Theoretical Investigation of Thermal Effectiveness in Multiperforated Plates for Combustor Liner Effusion Cooling
    Andreini, Antonio
    Facchini, Bruno
    Picchi, Alessio
    Tarchi, Lorenzo
    Turrini, Fabio
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2014, 136 (09):
  • [5] Correlation of film-cooling effectiveness from thermographic measurements at enginelike conditions
    Baldauf, S
    Scheurlen, M
    Schulz, A
    Wittig, S
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 686 - 698
  • [6] Detailed heat transfer investigation of an impingement jet array with large jet-to-jet distance
    Chen, Lingling
    Brakmann, Robin G. A.
    Weigand, Bernhard
    Crawford, Michael
    Poser, Rico
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 146
  • [7] Local heat/mass transfer measurement on the effusion plate in impingement/effusion cooling systems
    Cho, HH
    Rhee, DH
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 601 - 608
  • [8] Momentum and Thermal Boundary Layer Development on an Internally Cooled Turbine Vane
    Dees, Jason E.
    Bogard, David G.
    Ledezma, Gustavo A.
    Laskowski, Gregory M.
    Tolpadi, Anil K.
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2012, 134 (06):
  • [9] Deng Q., 2016, P ASME TURB EXP ASME
  • [10] PERIODIC STREAMWISE VARIATIONS OF HEAT-TRANSFER COEFFICIENTS FOR IN-LINE AND STAGGERED ARRAYS OF CIRCULAR JETS WITH CROSS-FLOW OF SPENT AIR
    FLORSCHUETZ, LW
    BERRY, RA
    METZGER, DE
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1980, 102 (01): : 132 - 137