Experimental and numerical investigation of the seismic performance of railway piers with increasing longitudinal steel in plastic hinge area

被引:14
作者
Lu, Jinhua [1 ]
Chen, Xingchong [1 ]
Ding, Mingbo [1 ,2 ]
Zhang, Xiyin [1 ]
Liu, Zhengnan [1 ]
Yuan, Hao [1 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Civil Engn, Lanzhou 730070, Gansu, Peoples R China
[2] Lanzhou Jiaotong Univ, Key Lab Rd & Bridge & Underground Engn Gansu Prov, Lanzhou 730070, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
increased longitudinal reinforcement; railway bridge piers; quasi-static test; seismic performance; FIBER-REINFORCED POLYMER; EXISTING BRIDGE COLUMNS; CONCRETE COLUMNS; BOND-SLIP; CYCLIC BEHAVIOR; LAP SPLICES; SQUARE; MODEL; EARTHQUAKE; RETROFIT;
D O I
10.12989/eas.2019.17.6.545
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bridge piers with bending failure mode are seriously damaged only in the area of plastic hinge length in earthquakes. For this situation, a modified method for the layout of longitudinal reinforcement is presented, i.e., the number of longitudinal reinforcement is increased in the area of plastic hinge length at the bottom of piers. The quasi-static test of three scaled model piers is carried out to investigate the local longitudinal reinforcement at the bottom of the pier on the seismic performance of the pier. One of the piers is modified by increased longitudinal reinforcement at the bottom of the pier and the other two are comparative piers. The results show that the pier failure with increased longitudinal bars at the bottom is mainly concentrated at the bottom of the pier, and the vulnerable position does not transfer. The hysteretic loop curve of the pier is fuller. The bearing capacity and energy dissipation capacity is obviously improved. The bond-slip displacement between steel bar and concrete decreases slightly. The finite element simulations have been carried out by using ANSYS, and the results indicate that the seismic performance of piers with only increasing the number of steel bars (less than65%) in the plastic hinge zone can be basically equivalent to that of piers that the number of steel bars in all sections is the same as that in plastic hinge zone.
引用
收藏
页码:545 / 556
页数:12
相关论文
共 53 条
[1]   Numerical and hybrid analysis of a curved bridge and methods of numerical model calibration [J].
Abdelnaby, Adel E. ;
Frankie, Thomas M. ;
Elnashai, Amr S. ;
Spencer, Billie F. ;
Kuchma, Daniel A. ;
Silva, Pedro ;
Chang, Chia-Ming .
ENGINEERING STRUCTURES, 2014, 70 :234-245
[2]  
Aboutaha R.S., 1996, EARTHQ SPECTRA, V12, P693, DOI 10.1193/1.1585906
[3]  
Aboutaha RS, 1999, ACI STRUCT J, V96, P68
[4]  
[Anonymous], 1997, 10196 JGJ
[5]  
[Anonymous], 1995, Standard specifications for highway bridges, V15th
[6]  
[Anonymous], 2008, Guidelines for seismic design of highway bridges
[7]  
[Anonymous], 1990, EFFECT LATERAL CONFI
[8]  
[Anonymous], 1971, ENG FEATURES SAN FER
[9]  
[Anonymous], THESIS
[10]  
Association J.R, 1996, ROAD BRIDG DISPL BOO