Treatment of Interprosthetic Fractures of the Femur

被引:42
作者
Hou, Zhiyong [1 ]
Moore, Blake [2 ]
Bowen, Thomas R. [2 ]
Irgit, Kaan [2 ]
Matzko, Michelle E. [2 ]
Strohecker, Kent A. [2 ]
Smith, Wade R. [2 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthopaed Surg, Shijiazhuang 050051, Hebei, Peoples R China
[2] Geisinger Med Ctr, Dept Orthopaed Surg, Danville, PA 17822 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2011年 / 71卷 / 06期
关键词
Interprosthetic fracture; Knee arthroplasty; Hip arthroplasty; Locked plating; TOTAL KNEE ARTHROPLASTY; FEMORAL FRACTURES; PERIPROSTHETIC FRACTURES; MENNEN PLATE; HIP; FIXATION; SHAFT;
D O I
10.1097/TA.0b013e31821dd9f1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The treatment of interprosthetic femoral fractures is challenging because of several factors. Poor bone stock, advanced age, potential prosthetic instability, and limited fracture fixation options both proximally and distally can complicate standard femur fracture treatment procedures. The purpose of this report was to describe our experience treating interprosthetic femoral fractures, providing an emphasis on treatment principles and specific intraoperative management. Methods: All patients with fractures occurring between ipsilateral hip and knee prostheses between 2004 and 2010 were identified from a comprehensive database and included in this study. Patients had been treated using principles adapted from two isolated periprosthetic fracture classification systems, the Vancouver and Su classifications. The electronic medical record (including inpatient medical records, operative notes, outpatient medical records, and all radiographs) was reviewed for each patient and demographic and treatment-related variables as well as complications and outcomes were recorded. Results: Thirteen consecutive patients with interprosthetic fractures were included. Four fractures occurred around a clearly loose prosthesis, which were subsequently treated with long-stemmed revisions. The remaining 12 fractures were treated with a locked-plate construct. Two of nine patients (22.2%) died before fracture union. Follow-up averaged 28 months +/- 4 months, with fracture union achieved at an average of 4.7 months +/- 0.3 months. All patients returned to their self-reported preoperative ambulatory status except one who developed a loose hip prosthesis at 3-year follow-up after fracture union. Conclusions: The principles for treatment of isolated periprosthetic fractures are useful to guide the fixation of interprosthetic fractures. Locked plating is an effective method for the treatment of interprosthetic femoral fractures. Bypassing the adjacent prosthesis by a minimum of two femoral diameters is a necessary technique to prevent a stress riser.
引用
收藏
页码:1715 / 1719
页数:5
相关论文
共 18 条
[1]   Epidemiology - Hip and knee [J].
Berry, DJ .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :183-+
[2]   The reliability and validity of the Vancouver classification of femoral fractures after hip replacement [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :59-62
[3]   Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients [J].
Chakravarthy, Jagannath ;
Bansal, Rajeev ;
Cooper, Julian .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :725-733
[4]  
Dave D J, 1995, J Arthroplasty, V10, P113, DOI 10.1016/S0883-5403(06)80075-6
[5]   Interprosthetic fracture of the femoral shaft treated with a percutaneously inserted dynamic condylar screw: Case report [J].
Della Valle, CJ ;
Tejwani, N ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (03) :602-605
[6]   Periprosthetic fractures of the femur associated with hip arthroplasty [J].
Fink, B ;
Fuerst, M ;
Singer, J .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (07) :433-442
[7]   The Mennen plate: unsuitable for elderly femoral peri-prosthetic fractures [J].
Kamineni, S ;
Ware, HE .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (04) :257-260
[8]   The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis [J].
Kampshoff, Jorg ;
Stoffel, Karl K. ;
Yates, Piers J. ;
Erhardt, Johannes B. ;
Kuster, Markus S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (05) :627-632
[9]   Interprosthetic fracture of the femoral shaft [J].
Kenny, P ;
Rice, J ;
Quinlan, W .
JOURNAL OF ARTHROPLASTY, 1998, 13 (03) :361-364
[10]   Distal femoral fixation: A biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate [J].
Koval, KJ ;
Hoehl, JJ ;
Kummer, FJ ;
Simon, JA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (07) :521-524