Imaging using energy discriminating radiation detector array

被引:0
|
作者
Wilson, PD [1 ]
Clajus, M [1 ]
Tümer, TO [1 ]
Visser, G [1 ]
Cajipe, V [1 ]
机构
[1] USA, TACOM, ARDEC, Qual Engn Directorate, Picatinny Arsenal, NJ 07806 USA
来源
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY | 2003年 / 680卷
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Industrial X-ray radiography is often done using a broad band energy source and always a broad band energy detector. There exist several major advantages in the use of narrow band sources and or detectors, one of which is the separation of scattered radiation from primary radiation. ARDEC has developed a large detector array system in which every detector element acts like a multi-channel analyzer. A radiographic image is created from the number of photons detected in each detector element, rather than from the total energy absorbed in the elements. For high energies, 25 KeV to 4 MeV, used in radiography, energy discriminating detectors have been limited to less than 20,000 photons per second per detector element. This rate is much too slow for practical radiography. Our detector system processes over two million events per second per detector pixel, making radiographic imaging practical. This paper expounds on the advantages of the ARDEC radiographic imaging process.
引用
收藏
页码:913 / 918
页数:6
相关论文
共 50 条
  • [1] Low Energy Gamma Ray Imaging with a Detector Array
    Pan, Feng
    Dixon, Walter V.
    Katz, Sarah
    Yanoff, Brian D.
    Bures, Brian L.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [2] ENERGY DISCRIMINATING DETECTOR FOR DUAL ENERGY CT
    PLEWES, DB
    INVESTIGATIVE RADIOLOGY, 1979, 14 (05) : 399 - 399
  • [3] IMAGING PROPERTIES OF AN ENERGY DISCRIMINATING X-RAY DETECTOR BASED ON CDTE
    Koenig, T.
    Zuber, M.
    Zwerger, A.
    Fauler, A.
    Nill, S.
    Fiederle, M.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S433 - S434
  • [4] Investigation of energy weighting using an energy discriminating photon counting detector for breast CT
    Kalluri, Kesava S.
    Mahd, Mufeed
    Glick, Stephen J.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [5] Characterization of a silicon pixel detector for imaging with low energy radiation
    Caria, M
    Cadeddu, S
    Lai, A
    Sesselego, A
    Quarati, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 170 - 174
  • [6] PIXE imaging of hyperaccumulator plants using the Maia detector array
    Laird, Jamie S.
    Ryan, Chris G.
    Kirkham, Robin A.
    van der Ent, Antony
    Jamieson, David N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 451 : 73 - 78
  • [7] A NEW ENERGY DISCRIMINATING DETECTOR FOR DUAL ENERGY COMPUTED-TOMOGRAPHY
    PLEWES, DB
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 773 - 773
  • [8] Fluorescence hyperspectral imaging (fHSI) using a spectrally resolved detector array
    Luthman, Anna Siri
    Dumitru, Sebastian
    Quiros-Gonzalez, Isabel
    Joseph, James
    Bohndiek, Sarah E.
    JOURNAL OF BIOPHOTONICS, 2017, 10 (6-7) : 840 - 853
  • [9] High-resolution ultrasonic imaging using an etalon detector array
    Huang, Sheng-Wen
    Hou, Yang
    Ashkenazi, Shai
    O'Donnell, Matthew
    APPLIED PHYSICS LETTERS, 2008, 93 (11)
  • [10] Photoacoustic projection imaging using an all-optical detector array
    Bauer-Marschallinger, J.
    Felbermayer, K.
    Berer, T.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494