Electronic interface systems for goals of spectral domain optical coherence tomography

被引:19
作者
Gelikonov, V. M. [1 ,2 ]
Gelikonov, G. V. [1 ,2 ]
Terpelov, D. A. [1 ,2 ]
Shilyagin, P. A. [1 ,2 ]
机构
[1] Russian Acad Sci, Inst Appl Phys, Nizhnii Novgorod 603950, Russia
[2] LLC Biomed Technol, Nizhnii Novgorod 603155, Russia
关键词
COMPENSATION;
D O I
10.1134/S0020441212020042
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A setup for visualizing the internal structure of media, which partially scatter radiation, using the spectral domain optical coherence tomography (OCT) method is described. The special complex of electron interface systems, ensuring the operating speed of the spectral domain OCT system at a level of 10000 A-scans (longitudinal scans along the depth) per second, high dynamic imaging range, and complete suppression of coherent noise peculiar to the spectral method has been designed to eliminate artifacts characteristic of this method.
引用
收藏
页码:392 / 398
页数:7
相关论文
共 20 条
[1]   Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution [J].
Bachmann, AH ;
Leitgeb, RA ;
Lasser, T .
OPTICS EXPRESS, 2006, 14 (04) :1487-1496
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Cost effective, all-fiber autocorrelator based 1300 mn OCT system [J].
Feldchtein, F ;
Bush, J ;
Gelikonov, G ;
Gelikonov, V ;
Piyevsky, S .
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 :349-355
[4]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[5]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[6]   Fibreoptic methods of cross-polarisation optical coherence tomography for endoscopic studies [J].
Gelikonov, V. M. ;
Gelikonov, G. V. .
QUANTUM ELECTRONICS, 2008, 38 (07) :634-640
[7]   A control system for the optical-fiber piezoelectric modulator of the optical path [J].
Gelikonov, V. M. ;
Gelikonov, G. V. ;
Ksenofontov, S. Yu. ;
Terpelov, D. A. ;
Shilyagin, P. A. .
INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (03) :443-446
[8]   SUPPRESSION OF IMAGE ARTIFACTS IN THE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [J].
Gelikonov, V. M. ;
Kasatkina, I. V. ;
Shilyagin, P. A. .
RADIOPHYSICS AND QUANTUM ELECTRONICS, 2009, 52 (11) :810-821
[9]   Coherent noise compensation in Spectral-Domain optical coherence tomography [J].
Gelikonov, V. M. ;
Gelikonov, G. V. ;
Kasatkina, I. V. ;
Terpelov, D. A. ;
Shilyagin, P. A. .
OPTICS AND SPECTROSCOPY, 2009, 106 (06) :895-900
[10]   Optimization of Fizeau-based optical coherence tomography with a reference Michelson interferometer [J].
V. M. Gelikonov ;
G. V. Gelikonov ;
P. A. Shilyagin .
Bulletin of the Russian Academy of Sciences: Physics, 2008, 72 (1) :93-97