Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples

被引:96
|
作者
Karimi-Maleh, Hassan [1 ]
Ensafi, Ali A. [2 ]
Beitollahi, Hadi [3 ]
Nasiri, Vahid [4 ]
Khalilzadeh, Mohammad A. [5 ]
Biparva, Pourya [6 ]
机构
[1] Islamic Azad Univ, Majlesi Branch, Dept Chem, Esfahan, Iran
[2] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[3] Int Ctr Sci High Technol & Environm Sci, Res Inst Environm Sci, Dept Environm, Kerman, Iran
[4] Islamic Azad Univ, Qaemshahr Branch, Dept Chem, Qaemshahr, Iran
[5] Islamic Azad Univ, Sci & Res Branch, Dept Chem, Mazandaran, Iran
[6] Islamic Azad Univ, Sci & Res Branch, Dept Nanotechnol, Langaroud, Iran
关键词
Sulfite; Carbon nanotubes paste electrode; Ferrocene; Voltammetry; Electrocatalysis; FOLIC-ACID; URIC-ACID; FERROCENEDICARBOXYLIC ACID; VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; SENSOR; EPINEPHRINE; OXIDATION; FILM; LEVODOPA;
D O I
10.1007/s11581-011-0654-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper introduces a carbon paste electrode modified with ferrocene and carbon nanotubes as a voltammetric sensor for determination of sulfite at pH 7.0. The results showed that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurred at a potential about 280 mV less positive than the unmodified carbon paste electrode. Kinetic parameters such as electron transfer coefficient (alpha) and heterogeneous rate constant (k) for sulfite were also determined using electrochemical approaches. Under the optimized conditions, the electrocatalytic oxidation peak current of sulfite showed two linear dynamic ranges with a detection limit of 0.1 mu M for sulfite. The proposed method was examined as a selective, simple, and precise method for voltammetric determination of sulfite in some real samples such as weak liquor from wood and paper industry, boiler water, river water, industrial water, and tap water.
引用
收藏
页码:687 / 694
页数:8
相关论文
共 50 条
  • [41] Ferrocenedicarboxylic Acid Modified Carbon Paste Electrode: A Sensor for Electrocatalytic Determination of Hydrochlorothiazide
    Karimi-Maleh, H.
    Ensafi, Ali A.
    Ensafi, Hamid R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (05) : 880 - 887
  • [42] Electrocatalytic Determination of Hydroxylamine in the Presence of Thiosulfate in Water and Wastewater Samples Using a Nanostructure Modified Carbon Paste Electrode
    Shabani-Nooshabadi, Mehdi
    Tahernejad-Javazmi, Fahimeh
    ELECTROANALYSIS, 2015, 27 (07) : 1733 - 1741
  • [43] Electrochemical Behaviour of a Modified Carbon Nanotube Paste Electrode and Its Application for Simultaneous Determination of Epinephrine, Uric Acid and Folic Acid
    Mohamrnadi, Somayeh
    Beitollahi, Hadi
    Mohadesi, Alireza
    SENSOR LETTERS, 2013, 11 (02) : 388 - 394
  • [44] Electrocatalytic Determination of 6-Mercaptopurine Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Methyldopa
    Isfahani, Ali Sharifian
    Keyvanfard, Mohsen
    Rezaei, Behzad
    Alizad, Khadijeh
    CURRENT NANOSCIENCE, 2014, 10 (04) : 512 - 520
  • [45] Electrocatalytic voltammetric determination of guanine at a cobalt phthalocyanine modified carbon nanotubes paste electrode
    Balan, Ionela
    David, Iulia Gabriela
    David, Vasile
    Stoica, Anca-Iulia
    Mihailciuc, Constantin
    Stamatin, Ioan
    Ciucu, Anton Alexandru
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 654 (1-2) : 8 - 12
  • [46] Voltammetric determination of isoproterenol using multiwall carbon nanotubes-ionic liquid paste electrode
    Ensafi, Ali A.
    Karimi-Maleh, H.
    DRUG TESTING AND ANALYSIS, 2011, 3 (05) : 325 - 330
  • [47] Electrochemical determination of hydrochlorothiazide and folic acid in real samples using a modified graphene oxide sheet paste electrode
    Beitollahi, Hadi
    Hamzavi, Mozhdeh
    Torkzadeh-Mahani, Masoud
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 : 297 - 305
  • [48] A Differential Pulse Voltammetric Sensor for Determination of Glutathione in Real Samples Using a Trichloro(terpyridine) ruthenium (III)/Multiwall Carbon Nanotubes Modified Paste Electrode
    Rezaei, Behzad
    Khosropour, Hossein
    Ensafi, Ali Asghar
    Hadadzadeh, Hassan
    Farrokhpour, Hossein
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 483 - 490
  • [49] Using Carbon Paste Electrode Modified with Graphene and Nanodiamond for the Determination of Nimesulide in Biologic and Environmental Samples
    Santos, Anderson M.
    Wong, Ademar
    Feitosa, Maria H. A.
    Silva, Lais P.
    Fatibello-Filho, Orlando
    Moraes, Fernando C.
    ELECTROANALYSIS, 2022, 34 (09) : 1441 - 1449
  • [50] Electrocatalytic Determination of L-cysteine in the Presence of Tryptophan Using Carbon Paste Electrode Modified with MgO Nanoparticles and Acetylferrocene
    Gupta, Vinod Kumar
    Shamsadin-Azad, Zahra
    Cheraghi, Somaye
    Agarwai, Shilpi
    Taher, Mohammad A.
    Karimi, Fatemeh
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05): : 4309 - 4318