Determination of nickel and cobalt in reference plant materials by carbon slurry sampling GFAAS technique after their simultaneous preconcentration onto modified activated carbon

被引:34
作者
Dobrowolski, Ryszard [1 ]
Otto, Magdalena [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Dept Analyt Chem & Instrumental Anal, PL-20031 Lublin, Poland
关键词
Trace element determination; Nickel; Cobalt; Modified activated carbons; Preconcentration; Food analysis; Food safety; Slurry sampling graphite furnace atomic absorption spectrometry; Food composition; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; CLOUD POINT EXTRACTION; OPTICAL-EMISSION SPECTROMETRY; NATURAL-WATER SAMPLES; ONLINE PRECONCENTRATION; AQUEOUS-SOLUTION; TRACE-ELEMENTS; FOOD SAMPLES; METAL-IONS;
D O I
10.1016/j.jfca.2012.03.002
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A novel method, in which dimethylglyoxime impregnated activated carbon (DMGC*) has been applied for preconcentration and further simultaneous determination of Ni(II) and Co(II) ions in the reference plant materials by the carbon slurry sampling graphite furnace atomic absorption spectrometry technique (GFAAS), is presented. Moreover, for comparison and evaluation, the activated carbons modified in different ways, e.g. oxidized with concentrated HNO3 solution (OC*) and outgassed at high temperature (OGC*), were prepared and carefully characterized, especially in terms of their selectivity. The method after preconcentration on DMGC* carbon has been successfully tested by the analysis of certified reference materials (spinach leaves: NIST 1570a and NCS ZC73013, mixed Polish herbs INCT-MPH-2, tea leaves INCT-TL-1), using carbon slurry sampling GFAAS and the standard calibration method. The obtained detection limits for nickel and cobalt were 0.02 and 0.001 mu g/g, and quantification limits were 0.06 and 0.004, respectively. The precision (RSD% about 7%) and accuracy of nickel and cobalt determination by the described method were acceptable. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:58 / 65
页数:8
相关论文
共 46 条
[1]   A permeation liquid membrane system for determination of nickel in seawater [J].
Aouarram, A. ;
Galindo-Riano, M. D. ;
Garcia-Vargas, M. ;
Stitou, M. ;
El Yousfi, F. .
TALANTA, 2007, 71 (01) :165-170
[2]   Solidified floating organic drop microextraction (SFODME) for simultaneous separation/preconcentration and determination of cobalt and nickel by graphite furnace atomic absorption spectrometry (GFAAS) [J].
Bidabadi, Mahboubeh Shirani ;
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (01) :291-296
[3]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[4]   Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC) [J].
Cassella, RJ ;
Salim, VA ;
Jesuíno, LS ;
Santelli, RE ;
Ferreira, SLC ;
de Carvalho, MS .
TALANTA, 2001, 54 (01) :61-67
[5]   On-line preconcentration of nickel on activated carbon prior to its determination by vapor generation associated to inductively coupled plasma optical emission spectrometry [J].
Cerutti, S ;
Moyano, S ;
Marrero, J ;
Smichowski, P ;
Martinez, LD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (06) :559-561
[6]   On-line preconcentration of cobalt in drinking water using a minicolumn packed with activated carbon coupled to electrothermal atomic absorption spectrometric determination [J].
Cerutti, S ;
Moyano, S ;
Gásquez, JA ;
Stripeikis, J ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (11) :2015-2021
[7]   Sorption of PAR-metal complexes on activated carbon as a rapid preconcentration method for the determination of Cu, Co, Cd, Cr, Ni, Pb and V in ground water [J].
Chakrapani, G ;
Murty, DSR ;
Mohanta, PL ;
Rangaswamy, R .
JOURNAL OF GEOCHEMICAL EXPLORATION, 1998, 63 (02) :145-152
[8]   Surface charge and metal ion adsorption on an H-type activated carbon: experimental observation and modeling simulation by the surface complex formation approach [J].
Chen, JP ;
Lin, MS .
CARBON, 2001, 39 (10) :1491-1504
[9]   Slurry Sampling-An Analytical Strategy for the Determination of Metals and Metalloids by Spectroanalytical Techniques [J].
Costa Ferreira, Sergio Luis ;
Miro, Manuel ;
Paranhos da Silva, Erik Galvao ;
Matos, Geraldo Domingues ;
dos Reis, Pedro Sanches ;
Brandao, Geovani Cardoso ;
Lopes dos Santos, Walter Nei ;
Duarte, Alvaro Tavares ;
Rodrigues Vale, Maria Goreti ;
Oliveira Araujo, Rennan Geovanny .
APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (01) :44-62
[10]   A novel ionic liquid/micro-volume back extraction procedure combined with flame atomic absorption spectrometry for determination of trace nickel in samples of nutritional interest [J].
Dadfarnia, Shayesteh ;
Shabani, Ali Mohammad Haji ;
Bidabadi, Mahboubeh Shirani ;
Jafari, Abbas Ali .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) :534-538