AC Losses in Bi2Sr2Ca2Cu3O10+x Tapes and a 3.15-m-Long Single-Phase Cable

被引:1
作者
Juul, Jeppe Sogaard [1 ]
Molgaard, Esben Tore [2 ]
Jensen, Jens
Andersen, Niels Hessel [3 ]
Abrahamsen, Asger Bech [3 ]
Willen, Dag [4 ]
Traeholt, Chresten [4 ,5 ]
Thidemann, Carsten
Lentge, Heidi [4 ]
机构
[1] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[2] Univ So Denmark, CP3 Origins Ctr, DK-5230 Odense, Denmark
[3] Tech Univ Denmark, Riso DTU Natl Lab Sustainable Energy, Mat Res Div, Lyngby, Denmark
[4] Ultera A Southwire NKT Cables Joint Venture, DK-2605 Brondby, Denmark
[5] Tech Univ Denmark, DK-2800 Lyngby, Denmark
关键词
High-temperature superconductors (HTSs); loss measurement; magnetic losses; multifilamentary superconductors; SUPERCONDUCTING CABLE; CALORIMETRIC METHODS; TRANSPORT CURRENT; HTS CABLE; CONDUCTORS; LONG;
D O I
10.1109/TASC.2011.2166153
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The alternating-current losses in superconducting multifilament BiSCCO-2223 tapes and a 3.15-m single-phase test cable were measured at 77 K using an electrical transport method. The cable had an inner diameter of 42 mm; it was composed of a single layer of 31 multifilament tapes and had a critical current of I-c = 4.1 kA. The measured losses of the tapes were found to be in good agreement with the Norris ellipse (NE) model. The losses of the cable were, for high currents, found to be bounded by the monoblock and independent NE models.
引用
收藏
页码:3599 / 3603
页数:5
相关论文
共 19 条
[1]   AC loss reduction of superconducting power transmission cables composed of coated conductors [J].
Amemiya, Naoyuki ;
Jiang, Zhenan ;
Nakahata, Masaaki ;
Yagi, Masashi ;
Mukoyama, Shinichi ;
Kashima, Naoji ;
Nagaya, Shigeo ;
Shiohara, Yuh .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1712-1717
[2]   MAGNETIZATION OF HIGH-FIELD SUPERCONDUCTORS [J].
BEAN, CP .
REVIEWS OF MODERN PHYSICS, 1964, 36 (1P1) :31-+
[3]   Comparison between self-field AC losses of a single-phase Bi-2223 cable measured by electric and calorimetric methods [J].
Cereda, E ;
Coletta, G ;
Crotti, G ;
Gherardi, L ;
Ottoboni, G ;
Zannella, S .
PHYSICA C, 1998, 310 (1-4) :231-235
[4]   Application of electrical and calorimetric methods to the AC loss characterization of cable conductors [J].
Coletta, G ;
Gherardi, L ;
Gömöry, F ;
Cereda, E ;
Ottoboni, V ;
Daney, D ;
Maley, M ;
Zannella, S .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) :1053-1056
[5]   Ac power loss for superconducting strips of arbitrary thickness in the critical state carrying a transport current [J].
Daumling, M .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1998, 11 (06) :590-593
[6]   Numerical study on AC transport current loss measurement of HTS assembled conductor by pick-up loop without electrical contacts [J].
Fukui, Satoshi ;
Watanabe, So ;
Ogawa, Jun ;
Yamaguchi, Mitsugi ;
Sato, Takao ;
Tsukamoto, Osami .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1704-1707
[7]   Ac losses in Bi-2223 tapes for power applications [J].
Gherardi, L ;
Gomory, F ;
Mele, R ;
Coletta, G .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1997, 10 (12) :909-913
[8]   Phase shifts of parallel currents in a single-layer model of superconducting cables [J].
Gömöry, F ;
Frolek, L ;
Souc, J ;
Grilli, F .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :1779-1782
[9]   Transport AC losses in round superconducting wire consisting of two concentric shells with different critical current density [J].
Gomory, F ;
Gherardi, L .
PHYSICA C, 1997, 280 (03) :151-157
[10]   Analysis of AC losses in a tri-axial superconducting cable [J].
Hamajima, T. ;
Tsuda, M. ;
Yagai, T. ;
Monma, S. ;
Satoh, H. ;
Shimoyama, K. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1692-1695