Determination of arsenic and cadmium in crude oil by direct sampling graphite furnace atomic absorption spectrometry

被引:26
作者
de Jesus, Alexandre [1 ]
Zmozinski, Ariane Vanessa [1 ]
Ferreira Damin, Isabel Cristina [2 ]
Silva, Marcia Messias [1 ,3 ]
Rodrigues Vale, Maria Goreti [1 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Fac Dom Bosco Porto Alegre, BR-90520280 Porto Alegre, RS, Brazil
[3] Univ Fed Bahia, Inst Natl Ciencia & Tecnol CNPq, INCT Energia & Ambiente, BR-40170115 Salvador, BA, Brazil
关键词
Arsenic; Cadmium; Direct sampling; Graphite furnace atomic absorption spectrometry; PETROLEUM; VANADIUM; METALS; COPPER; NICKEL; LEAD; STABILIZATION; NAPHTHA; FILTER;
D O I
10.1016/j.sab.2012.03.010
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, a direct sampling graphite furnace atomic absorption spectrometry method has been developed for the determination of arsenic and cadmium in crude oil samples. The samples were weighed directly on the solid sampling platforms and introduced into the graphite tube for analysis. The chemical modifier used for both analytes was a mixture of 0.1% Pd + 0.06% Mg + 0.06% Triton X-100. Pyrolysis and atomization curves were obtained for both analytes using standards and samples. Calibration curves with aqueous standards could be used for both analytes. The limits of detection obtained were 5.1 mu g kg(-1) for arsenic and 0.2 mu g kg(-1) for cadmium, calculated for the maximum amount of sample that can be analyzed (8 mg and 10 mg) for arsenic and cadmium, respectively. Relative standard deviations lower than 20% were obtained. For validation purposes, a calibration curve was constructed with the SRM 1634c and aqueous standards for arsenic and the results obtained for several crude oil samples were in agreement according to paired t-test. The result obtained for the determination of arsenic in the SRM against aqueous standards was also in agreement with the certificate value. As there is no crude oil or similar reference material available with a certified value for cadmium, a digestion in an open vessel under reflux using a "cold finger" was adopted for validation purposes. The use of paired t-test showed that the results obtained by direct sampling and digestion were in agreement at a 95% confidence level. Recovery tests were carried out with inorganic and organic standards and the results were between 88% and 109%. The proposed method is simple, fast and reliable, being appropriated for routine analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 21 条
[1]   Atomic spectrometric methods for the determination of metals and metalloids in automotive fuels - A review [J].
Andrade Korn, Maria das Gracas ;
Sodre dos Santos, Denilson Santana ;
Welz, Bernhard ;
Rodrigues Vale, Maria Goreti ;
Teixeira, Alete Paixao ;
Lima, Daniel de Castro ;
Ferreira, Sergio Luis Costa .
TALANTA, 2007, 73 (01) :1-11
[2]   Direct determination of arsenic in petroleum derivatives by graphite furnace atomic absorption spectrometry: A comparison between filter and platform atomizers [J].
Becker, Emilene ;
Rampazzo, Roger T. ;
Dessuy, Morgana B. ;
Vale, Maria Goreti R. ;
da Silva, Marcia M. ;
Welz, Bernhard ;
Katskov, Dmitri A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) :345-351
[3]   Direct determination of nickel in petroleum by solid sampling-graphite furnace atomic absorption spectrometry [J].
Brandao, Geisamanda Pedrini ;
de Campos, Reinaldo Calixto ;
Ribeiro de Castro, Eustaquio Vinicius ;
de Jesus, Honerio Coutinho .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :2249-2253
[4]   Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier [J].
Cassella, RJ ;
Barbosa, BARS ;
Santelli, RE ;
Rangel, AT .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (01) :66-71
[5]   Comparison of direct sampling and emulsion analysis using a filter furnace for the determination of lead in crude oil by graphite furnace atomic absorption spectrometry [J].
Damin, Isabel C. F. ;
Dessuy, Morgana B. ;
Castilhos, Tamara S. ;
Silva, Marcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard ;
Katskov, Dmitri A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (06) :530-536
[6]   Direct and simultaneous determination of Cr and Fe in crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Dittert, Ingrid M. ;
Silva, Jessee S. A. ;
Araujo, Rennan G. O. ;
Curtius, Adilson J. ;
Welz, Bernhard ;
Becker-Ross, Helmut .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (06) :537-543
[7]   Determination of metals in crude oil by atomic Spectroscopy [J].
Hardaway, C ;
Sneddon, J ;
Beck, JN .
ANALYTICAL LETTERS, 2004, 37 (14) :2881-2899
[8]   Direct determination of arsenic in beer by electrothermal atomic absorption spectrometry with deuterium background correction (D2-ET-AAS) [J].
Husakova, Lenka ;
Cernohorsky, Tomas ;
Sramkova, Jitka ;
Vavrusova, Lenka .
FOOD CHEMISTRY, 2007, 105 (01) :286-292
[9]  
Kurfurst U., 1998, SOLID SAMPLE ANAL
[10]   FACTORS CONTROLLING ENRICHMENT OF VANADIUM AND NICKEL IN THE BITUMEN OF ORGANIC SEDIMENTARY-ROCKS [J].
LEWAN, MD ;
MAYNARD, JB .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1982, 46 (12) :2547-2560