Retractable Loop-Gap Resonators for Electron Paramagnetic Resonance Imaging with In Situ Irradiation Capabilities

被引:5
|
作者
Epel, Boris [1 ]
Sundramoorthy, Subramanian V. [1 ]
Halpern, Howard J. [1 ]
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Ctr EPR Imaging Vivo Physiol, Chicago, IL 60637 USA
关键词
EPR; EPR imaging; in vivo imaging; resonator;
D O I
10.1002/cmr.b.20205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A retractable split-top loop-gap resonator for both continuous wave and pulse electron paramagnetic resonance imaging of small animals with open, clam shell style design to allow convenient access to the sample for in situ animal irradiation is described. The resonator can be either rigidly attached to the animal support bed or floated independently from the bed to avoid communication of the mechanical vibrations of the bed to the resonator. Multiple split-top resonators for different animal sizes were built and tested. The characteristics of split-top resonators are comparable with those of loop-gap resonators used previously. The imaging experiments that involved the sham animal irradiation between pairs of images demonstrated very good maintenance of animal position between images. (C) 2011 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 39B: 167-172, 2011
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [41] MURINE INVIVO L-BAND ELECTRON-SPIN-RESONANCE SPIN-LABEL OXIMETRY WITH A LOOP-GAP RESONATOR
    SUBCZYNSKI, WK
    LUKIEWICZ, S
    HYDE, JS
    MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 747 - 754
  • [42] ELECTRON-PARAMAGNETIC RESONANCE OF ELECTRON-IRRADIATED GAP
    KENNEDY, TA
    WILSEY, ND
    PHYSICAL REVIEW B, 1981, 23 (12): : 6585 - 6591
  • [43] Novel multisample dielectric resonators for electron paramagnetic resonance spectroscopy
    Golovina, Iryna S.
    Kolesnik, Sergiy P.
    Geifman, Ilia N.
    Belous, Anatoliy G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (04):
  • [44] Mid-Range Wireless Power Transfer at 100 MHz Using Magnetically Coupled Loop-Gap Resonators
    Roberts, David M.
    Clements, Aaron P.
    McDonald, Rowan
    Bobowski, Jake S.
    Johnson, Thomas
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (07) : 3510 - 3527
  • [45] ELECTRON-PARAMAGNETIC RESONANCE OF GE DONORS IN GAP
    MEHRAN, F
    TITLE, RS
    BLUM, SE
    MORGAN, TN
    SOLID STATE COMMUNICATIONS, 1972, 11 (05) : 661 - &
  • [46] Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects
    Devasahayam, N
    Subramanian, S
    Murugesan, R
    Cook, JA
    Afeworki, M
    Tschudin, RG
    Mitchell, JB
    Krishna, MC
    JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (01) : 168 - 176
  • [47] On-Site/In Situ Continuous Detecting ppb-Level Metal Ions in Drinking Water Using Block Loop-Gap Resonators and Machine Learning
    Oh, Sangmin
    Hossen, Imtiaz
    Luglio, Juan
    Justin, Gusphyl
    Richie, James E.
    Medeiros, Henry
    Lee, Chung Hoon
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [48] Electron paramagnetic resonance imaging of the rat heart
    Zweier, JL
    Chzhan, M
    Samouilov, A
    Kuppusamy, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (07): : 1823 - 1835
  • [49] Spin probes for electron paramagnetic resonance imaging
    Yan GuoPing
    Peng Lei
    Jian ShuangQuan
    Li Liang
    Bottle, Steven Eric
    CHINESE SCIENCE BULLETIN, 2008, 53 (24): : 3777 - 3789
  • [50] Hyperfine artifacts in electron paramagnetic resonance imaging
    Kuppusamy, P
    Zweier, JL
    RESEARCH ON CHEMICAL INTERMEDIATES, 1996, 22 (06) : 593 - 604