A PET Design Based on SiPM and Monolithic LYSO Crystals: Performance Evaluation

被引:56
作者
Gonzalez, Antonio J. [1 ]
Aguilar, Albert [1 ]
Conde, Pablo [1 ]
Hernandez, Liczandro [1 ]
Moliner, Laura [1 ]
Vidal, Luis F. [1 ]
Sanchez, Filomeno [1 ]
Sanchez, Sebastian [1 ]
Correcher, Carlos [2 ]
Molinos, Cesar [2 ]
Barbera, Julio [2 ]
Lankes, Konrad [3 ]
Junge, Sven [3 ]
Bruckbauer, Thomas [3 ]
Bruyndonckx, Peter [3 ]
Benlloch, Jose M. [1 ]
机构
[1] Univ Politecn Valencia, CIEMAT, CSIC, I3M, E-46022 Valencia, Spain
[2] CIPF, Oncovis, Valencia 46013, Spain
[3] Bruker BioSpin, D-76275 Ettlingen, Germany
关键词
Gamma-ray detection; positron emission tomography; solid scintillation detectors; DETECTOR; SCINTILLATORS; ARRAY; SCANNER;
D O I
10.1109/TNS.2016.2522179
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new small animal PET based on SiPM and monolithic LYSO crystals has been developed. Eight detector modules form the PET ring, each mounting an array of 12 x 12 SiPMs coupled to a readout providing the summed signals of the pixels on each of the 12 rows and 12 columns of the SiPM array. This design makes it possible to accurately determine the centroid of the scintillation light distribution with about 1.6 mm full width at half maximum (FWHM) resolution without correction for the 1 mm source size, and the photon depth of interaction (DOI) with nearly 2 mm FWHM. This single ring PET system has a homogeneous spatial resolution across the entire 80 mm transaxial field of view (FOV) of about 1 mm FWHM. The noise equivalent count rate (NECR) peak is estimated to occur at around 39.2 MBq with a rate of approximately 82.7 kcps for the mouse-like phantom and 22 kcps at 48.1 MBq for the rat-like phantom. Following the NEMA protocol, the peak absolute sensitivity in the center of the FOV is 2.8% for a 30% peak energy window. A pilot test injecting NaF to a mouse of 20 grams is also presented. Finally, the PET ring has been tested in front of a high field 15.2 T Magnetic Resonance (MR). No significant variation on energy and spatial resolution across the FOV has been observed due to the presence of the magnetic field.
引用
收藏
页码:2471 / 2477
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 2008, NEM STAND PUBL
[2]  
Benlloch J. M., 2007, P IEEE NSS MIC C, P2594
[3]  
Caldeira L, 2012, IEEE NUCL SCI CONF R, P2327
[4]  
Conde P., 2014, P IEEE MIC C REC
[5]   Silicon Photomultipliers (SiPM) as novel photodetectors for PET [J].
Del Guerra, Alberto ;
Belcari, Nicola ;
Bisogni, Maria Giuseppina ;
Corsi, Francesco ;
Foresta, Maurizio ;
Guerra, Pedro ;
Marcatili, Sara ;
Santos, Andres ;
Sportelli, Giancarlo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S232-S235
[6]   DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators [J].
Espana, Samuel ;
Marcinkowski, Radoslaw ;
Keereman, Vincent ;
Vandenberghe, Stefaan ;
Van Holen, Roel .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) :3405-3420
[7]   Detector block based on arrays of 144 SiPMs and monolithic scintillators: A performance study [J].
Gonzalez, A. J. ;
Conde, P. ;
Iborra, A. ;
Aguilar, A. ;
Bellido, P. ;
Garcia-Olcina, R. ;
Hernandez, L. ;
Moline, L. ;
Rigla, J. P. ;
Rodriguez-Alvarez, M. J. ;
Sanchez, F. ;
Seimetz, M. ;
Soriano, A. ;
Torres, J. ;
Vidal, L. F. ;
Benlloch, J. M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 :42-45
[8]   High-volume silicon photomultiplier production, performance, and reliability [J].
Jackson, Carl ;
O'Neill, Kevin ;
Wall, Liam ;
McGarvey, Brian .
OPTICAL ENGINEERING, 2014, 53 (08)
[9]   Novel detector technology for clinical PET [J].
Lecomte, Roger .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 :69-85
[10]  
Lerche C. W., 2006, P IEEE NSS MIC C, P2328