Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart

被引:270
作者
DeVore, GR
Falkensammer, P
Sklansky, MS
Platt, LD
机构
[1] Fetal Diagnost Ctr Pasadena, Pasadena, CA 91105 USA
[2] GE Med Syst Kretz Ultrasound, Zipf, Austria
[3] Univ So Calif, Keck Sch Med, Childrens Hosp Los Angeles, Dept Pediat,Div Pediat Cardiol, Los Angeles, CA USA
[4] Ctr Fetal Med & Womens Ultrasound, Los Angeles, CA USA
关键词
fetal heart; spatio-temporal image correlation; STIC;
D O I
10.1002/uog.217
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Spatio-temporal image correlation (STIC) is a new approach for clinical assessment of the fetal heart. It offers an easy to use technique to acquire data from the fetal heart and to aid in visualization with both two-dimensional and three-dimensional (3D) cine sequences. The acquisition is Performed in two steps: first, images are acquired by a single, automatic volume sweep. Second, the system analyzes the image data according to their spatial and temporal domain and processes an online dynamic 3D image sequence that is displayed in a multiplanar reformatted cross-sectional display and/or a surface rendered display. The examiner can navigate within the heart, re-slice, and produce all of the standard image planes necessary for a comprehensive diagnosis. The advantages of STIC for use in evaluation of the fetal heart are as follows: the technique delivers a temporal resolution which corresponds to a B-mode frame rate of approximately 80 frames/s; it provides the examiner with an unlimited number of images for review; it allows for correlation between image planes that are perpendicular to the main image acquisition plane; it may shorten the evaluation time when complex heart defects are suspected; it enables the reconstruction of a 3D rendered image that contains depth and volume which may provide additional information that is not available from the thin multiplanar image slices (e.g. for pulmonary veins, septal thickness); it lends itself to storage and review of volume data by the examiner or by experts at a remote site; it provides the examiner with the ability to review all images in a looped cine sequence. Copyright (C) 2003 ISUOG. Published by John Wiley Sons, Ltd.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 23 条
  • [1] SONOGRAPHIC DETECTION OF FETAL ANOMALIES OF THE AORTIC AND PULMONARY-ARTERIES - VALUE OF 4-CHAMBER VIEW VS DIRECT IMAGES
    BENACERRAF, BR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (06) : 1483 - 1489
  • [2] FETAL ECHOCARDIOGRAPHIC SCREENING FOR CONGENITAL HEART-DISEASE - THE IMPORTANCE OF THE 4-CHAMBER VIEW
    COPEL, JA
    PILU, G
    GREEN, J
    HOBBINS, JC
    KLEINMAN, CS
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (03) : 648 - 655
  • [3] A RANDOMIZED TRIAL OF PRENATAL ULTRASONOGRAPHIC SCREENING - IMPACT ON THE DETECTION, MANAGEMENT, AND OUTCOME OF ANOMALOUS FETUSES
    CRANE, JP
    LEFEVRE, ML
    WINBORN, RC
    EVANS, JK
    EWIGMAN, BG
    BAIN, RP
    FRIGOLETTO, FD
    MCNELLIS, D
    KANE, D
    BOYD, L
    CORNELISON, S
    PLATTNER, M
    CRAMER, DW
    HARLOW, BL
    TURLINGTON, T
    BURROWS, PK
    YAFFE, S
    CATZ, C
    QUILLIGAN, EJ
    HADLOCK, F
    HOBBINS, JC
    WILLIAMS, G
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (02) : 392 - 399
  • [4] Real-time three-dimensional fetal echocardiography optimal imaging windows
    Deng, J
    Sullivan, ID
    Yates, R
    Vogel, M
    Mcdonald, D
    Linney, AD
    Rodeck, CH
    Anderson, RH
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) : 1099 - 1105
  • [6] FETAL ECHOCARDIOGRAPHY - FACTORS THAT INFLUENCE IMAGING OF THE FETAL HEART DURING THE 2ND TRIMESTER OF PREGNANCY
    DEVORE, GR
    MEDEARIS, AL
    BEAR, MB
    HORENSTEIN, J
    PLATT, LD
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (11) : 659 - 663
  • [7] FETAL ECHOCARDIOGRAPHY .8. AORTIC ROOT DILATATION - A MARKER FOR TETRALOGY OF FALLOT
    DEVORE, GR
    SIASSI, B
    PLATT, LD
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 159 (01) : 129 - 136
  • [8] FETAL ECHOCARDIOGRAPHY .5. M-MODE MEASUREMENTS OF THE AORTIC ROOT AND AORTIC-VALVE IN 2ND-TRIMESTER AND 3RD-TRIMESTER NORMAL HUMAN FETUSES
    DEVORE, GR
    SIASSI, B
    PLATT, LD
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 152 (05) : 543 - 550
  • [9] DEVORE GR, 1992, J ULTRAS MED, V11, P345
  • [10] REPORT OF THE AMERICAN-SOCIETY-OF-ECHOCARDIOGRAPHY COMMITTEE-ON-NOMENCLATURE-AND-STANDARDS-IN-2-DIMENSIONAL-ECHOCARDIOGRAPHY
    HENRY, WL
    DEMARIA, A
    GRAMIAK, R
    KING, DL
    KISSLO, JA
    POPP, RL
    SAHN, DJ
    SCHILLER, NB
    TAJIK, A
    TEICHHOLZ, LE
    WEYMAN, AE
    [J]. CIRCULATION, 1980, 62 (02) : 212 - 217