摘要
Purpose: To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer. Materials and Methods: All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60.7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low-and high-energy tomographic data (below and above the k edge of iodine, respectively) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated. Results: Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem. Conclusion: The use of contrast-enhanced tomographic mammography has been demonstrated successfully in patients with promising diagnostic benefit. Further studies are necessary to fully assess diagnostic sensitivity and specificity. (C)RSNA, 2011
引用
收藏
页码:558 / 564
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 2007, ANN ICRP, V37, P1, DOI 10.1016/j.icrp.2007.11.001
[2]   Focal Cystic High-Attenuation Lesions: Characterization in Renal Phantom by Using Photon-counting Spectral CT-Improved Differentiation of Lesion Composition [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Nelson, Rendon C. ;
Schindera, Sebastian T. ;
Roessl, Ewald ;
Martens, Gerhard ;
Proksa, Roland ;
Fleiter, Thorsten R. ;
Schlomka, Jens-Peter .
RADIOLOGY, 2010, 254 (01) :270-276
[3]   Single-shot dual-energy subtraction mammography with electronic spectrum splitting: Feasibility [J].
Bornefalk, Hans ;
Lewin, John M. ;
Danielsson, Mats ;
Lundqvist, Mats .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (02) :275-278
[4]   Dual-energy contrast-enhanced digital breast tomosynthesis - a feasibility study [J].
Carton, A-K ;
Gavenonis, S. C. ;
Currivan, J. A. ;
Conant, E. F. ;
Schnall, M. D. ;
Maidment, A. D. A. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (988) :344-350
[5]   Initial clinical experience with contrast-enhanced digital breast tomosynthesis [J].
Chen, Sara C. ;
Carton, Ann-Katherine ;
Albert, Michael ;
Conant, Emily F. ;
Schnall, Mitchell D. ;
Maidment, Andrew D. A. .
ACADEMIC RADIOLOGY, 2007, 14 (02) :229-238
[6]   Digital mammography using iodine-based contrast media [J].
Diekmann, F ;
Diekmann, S ;
Jeunehomme, F ;
Muller, S ;
Hamm, B ;
Bick, U .
INVESTIGATIVE RADIOLOGY, 2005, 40 (07) :397-404
[7]   Use of iodine-based contrast media in digital full-field mammography -: Initial experience [J].
Diekmann, F ;
Diekmann, S ;
Taupitz, M ;
Bick, U ;
Winzer, KJ ;
Hüttner, C ;
Muller, S ;
Jeunehomme, F ;
Hamm, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (03) :342-345
[8]  
Diekmann F, 2001, Zentralbl Gynakol, V123, P117, DOI 10.1055/s-2001-12491
[9]   Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography [J].
Diekmann, Felix ;
Bick, Ulrich .
EUROPEAN RADIOLOGY, 2007, 17 (12) :3086-3092
[10]   Evaluation of contrast-enhanced digital mammography [J].
Diekmann, Felix ;
Freyer, Martin ;
Diekmann, Susanne ;
Fallenberg, Eva M. ;
Fischer, Thomas ;
Bick, Ulrich ;
Poellinger, Alexander .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) :112-121