Use of the NESMA Filter to Improve Myelin Water Fraction Mapping with Brain MRI

被引:19
作者
Bouhrara, Mustapha [1 ]
Reiter, David A. [2 ]
Maring, Michael C. [1 ]
Bonny, Jean-Marie [3 ]
Spencer, Richard G. [1 ]
机构
[1] NIA, Clin Invest Lab, NIH, Baltimore, MD 21224 USA
[2] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
[3] INRA, QuaPA UR370, F-63122 St Genes Champanelle, France
基金
美国国家卫生研究院;
关键词
Brain; GRASE; multispectral nonlocal filtering; myelin water fraction; QUANTITATIVE MAGNETIZATION-TRANSFER; MULTIPLE-SCLEROSIS; WHITE-MATTER; SPIN-ECHO; IN-VIVO; GRADIENT-ECHO; OFF-RESONANCE; TRANSVERSE RELAXATION; LAPLACE TRANSFORM; BAYESIAN-ANALYSIS;
D O I
10.1111/jon.12537
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Myelin water fraction (MWF) mapping permits direct visualization of myelination patterns in the developing brain and in pathology. MWF is conventionally measured through multiexponential T-2 analysis which is very sensitive to noise, leading to inaccuracies in derived MWF estimates. Although noise reduction filters may be applied during postprocessing, conventional filtering can introduce bias and obscure small structures and edges. Advanced nonblurring filters, while effective, exhibit a high level of complexity and the requirement for supervised implementation for optimal performance. The purpose of this paper is to demonstrate the ability of the recently introduced nonlocal estimation of multispectral magnitudes (NESMA) filter to greatly improve the determination of MWF parameter estimates from gradient and spin echo (GRASE) imaging data. METHODS RESULTS We evaluated the performance of the NESMA filter for MWF mapping from clinical GRASE imaging data of the human brain, and compared the results to those calculated from unfiltered images. Numerical and in vivo analyses of the brains of three subjects, representing different ages, were conducted. Our results demonstrated the potential of the NESMA filter to permit high-quality in vivo MWF mapping. Indeed, NESMA permits substantial reduction of random variation in derived MWF estimates while preserving accuracy and detail. CONCLUSIONS In vivo estimation of MWF in the human brain from GRASE imaging data was markedly improved through use of the NESMA filter. The use of NESMA may contribute to the goal of high-quality MWF mapping in clinically feasible imaging times.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 107 条
[61]   Feasibility of in vivo myelin water imaging using 3D multigradient-echo pulse sequences [J].
Lenz, C. ;
Klarhoefer, M. ;
Scheffler, K. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) :523-528
[62]   Reproducibility of In Vivo Magnetic Resonance Imaging-Based Measurement of Myelin Water [J].
Levesque, Ives R. ;
Chia, Charmaine L. L. ;
Pike, G. Bruce .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) :60-68
[63]   Quantitative Magnetization Transfer and Myelin Water Imaging of the Evolution of Acute Multiple Sclerosis Lesions [J].
Levesque, Ives R. ;
Giacomini, Paul S. ;
Narayanan, Sridar ;
Ribeiro, Luciana T. ;
Sled, John G. ;
Arnold, Doug L. ;
Pike, G. Bruce .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :633-640
[64]   IN-VIVO VISUALIZATION OF MYELIN WATER IN BRAIN BY MAGNETIC-RESONANCE [J].
MACKAY, A ;
WHITTALL, K ;
ADLER, J ;
LI, D ;
PATY, D ;
GRAEB, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :673-677
[65]  
MacKay Alex L, 2016, Brain Plast, V2, P71, DOI 10.3233/BPL-160033
[66]   ERRORS IN THE MEASUREMENTS OF T2 USING MULTIPLE-ECHO MRI TECHNIQUES .2. EFFECTS OF STATIC-FIELD INHOMOGENEITY [J].
MAJUMDAR, S ;
ORPHANOUDAKIS, SC ;
GMITRO, A ;
ODONNELL, M ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :562-574
[67]   Quantifying visual pathway axonal and myelin loss in multiple sclerosis and neuromyelitis optica [J].
Manogaran, Praveena ;
Vavasour, Irene M. ;
Lange, Alex P. ;
Zhao, Yinshan ;
McMullen, Katrina ;
Rauscher, Alexander ;
Carruthers, Robert ;
Li, David K. B. ;
Traboulsee, Anthony L. ;
Kolind, Shannon H. .
NEUROIMAGE-CLINICAL, 2016, 11 :743-750
[68]  
Maring MC, 2017, 26 INT SOC MAGN RES
[69]   Transverse relaxation and flip angle mapping: Evaluation of simultaneous and independent methods using multiple spin echoes [J].
McPhee, Kelly C. ;
Wilman, Alan H. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) :2057-2065
[70]   NUMERICAL INVERSION OF LAPLACE TRANSFORM AND SIMILAR FREDHOLM INTEGRAL-EQUATIONS OF 1ST KIND [J].
MCWHIRTER, JG ;
PIKE, ER .
JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1978, 11 (09) :1729-1745