Determination of glyoxal and methylglyoxal in atmospheric fine particulate matter by vortex-assisted micro-solid phase extraction and liquid chromatography-diode array detection

被引:16
|
作者
Naing, Nyi Nyi [1 ]
Lee, Hian Kee [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Environm Res Inst, T Lab Bldg 02-01,5A Engn Dr 1, Singapore 117411, Singapore
[2] Natl Univ Singapore, Dept Chem, 3 Sci Dr 3, Singapore 117543, Singapore
[3] Natl Univ Singapore, Trop Marine Sci Inst, S2S Bldg,18 Kent Ridge Rd, Singapore 119227, Singapore
关键词
alpha-dicarbonyl compounds; Micro-solid phase extraction; Atmospheric fine particulate matter; Derivatization; CARBON NANOTUBES; ORGANIC AEROSOL; ALDEHYDES; SORBENT; HPLC; QUANTIFICATION; GRAPHENE; IMPACT;
D O I
10.1016/j.chroma.2018.08.060
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of alpha-dicarbonyl compounds, glyoxal (Gly) and methyl glyoxal (Mgly), in atmospheric fine particulate matter PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 mu m) which play vital roles in generating secondary organic aerosols in the ambient air, was carried out by vortex-assisted micro-solid phase extraction (VA-mu-SPE)-liquid chromatography-diode array detection (LC-DAD), with on-sorbent derivatization by 2,4-dinitrophenylhydrazine (DNPH). This is the first time such an approach of combining on-sorbent derivatization and extraction in one step together with LC analysis has been applied to PM2.5. Extraction parameters such as selection of sorbent, extraction time, desorption time and sample volume were optimized using water samples spiked with Gly and Mgly. Under the most favourable conditions, good intra- (1.39%-2.78%) and inter-day (2.29%-6.56%) precision and linearity (ranging between 0.5 and 100 ng mL(-1)) along with coefficients of determination 0.998 and 0.997, were determined. The limits of detection were determined to be 0.14 ng mL(-1) (derivatized Gly) and 0.15 ng mL(-1) (derivatized Mgly) whereas the limits of quantification were 0.47 ng mL(-1) and 0.50 ng mL(-1), respectively. The developed method was successfully employed to the determination of Gly and Mgly associated with PM2.5. The latter was collected on glass fiber filters which were immersed in methanol: water (1:1 v/v) for mu-SPE, which was conducted using a sorbent pre-coated with DNPH. The concentrations of the Gly and Mgly were determined to be 0.38 ng m(-3) and 0.41 ng m(-3) in the sampled ambient air, with relative recoveries of between 69-97%. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [31] Determination of perfluorinated carboxylic acids in fish fillet by micro-solid phase extraction, followed by liquid chromatography-triple quadrupole mass spectrometry
    Lashgari, Maryam
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 26 - 32
  • [32] Simultaneous Determination of 18 Bioactive Compounds in Italian Bitter Liqueurs by Reversed-Phase High-Performance Liquid Chromatography-Diode Array Detection
    Mustafa, Ahmed M.
    Ricciutelli, Massimo
    Maggi, Filippo
    Sagratini, Gianni
    Vittori, Sauro
    Caprioli, Giovanni
    FOOD ANALYTICAL METHODS, 2014, 7 (03) : 697 - 705
  • [33] Ultrasound assisted combined molecularly imprinted polymer for the selective micro-solid phase extraction and determination of aflatoxins in fish feed using liquid chromatography-tandem mass spectrometry
    Madurangika Jayasinghe, G. D. Thilini
    Dominguez-Gonzalez, Raquel
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1609
  • [34] Analysis of benzoylurea insecticides in water samples with TiO2 nanotube array micro-solid phase extraction coupled to high performance liquid chromatography
    Zhou, Qingxiang
    Wu, Wei
    Huang, Yunrui
    RSC ADVANCES, 2014, 4 (86) : 45946 - 45952
  • [35] Development of highly hydrophobic fabric phase sorptive extraction membranes and exploring their applications for the rapid determination of tocopherols in edible oils analyzed by high pressure liquid chromatography-diode array detection
    Kalogiouri, Natasa P.
    Kabir, Abuzar
    Olayanju, Basit
    Furton, Kenneth G.
    Samanidou, Victoria F.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1664
  • [36] The core–shell nanosized magnetic molecularly imprinted polymers for selective preconcentration and determination of ciprofloxacin in human fluid samples using a vortex-assisted dispersive micro-solid-phase extraction and high-performance liquid chromatography
    Roya Mirzajani
    Ali Keshavarz
    Journal of the Iranian Chemical Society, 2019, 16 : 2291 - 2306
  • [37] Second-order calibration for the determination of fatty acids in pomegranate seeds by vortex-assisted extraction-dispersive liquid-liquid micro-extraction and gas chromatography-mass spectrometry
    Ahmadvand, Mohammad
    Sereshti, Hassan
    Parastar, Hadi
    RSC ADVANCES, 2015, 5 (15): : 11633 - 11643
  • [38] Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection
    Andrade, Roseane Teixeira
    Santos da Silva, Ricky Cassio
    Pereira, Arnaldo Cesar
    Borges, Keyller Bastos
    ANALYTICAL METHODS, 2015, 7 (17) : 7270 - 7279
  • [39] Determination of meropenem in endotracheal tubes by in-tube solid phase microextraction coupled to capillary liquid chromatography with diode array detection
    Hakobyan, L.
    Pla Tolos, J.
    Moliner-Martinez, Y.
    Molins-Legua, C.
    Ruiz Ramos, Jesus
    Gordon, M.
    Ramirez-Galleymore, Paula
    Campins-Falco, P.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 151 : 170 - 177
  • [40] A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection
    Tsochatzis, Emmanouil D.
    Menkissoglu-Spiroudi, Urania
    Karpouzas, Dimitrios G.
    Tzimou-Tsitouridou, Roxani