Electrochemical Aptamer-Based Biosensors for the Detection of Cardiac Biomarkers

被引:122
作者
Grabowska, Iwona [1 ]
Sharma, Neha [2 ]
Vasilescu, Alina [3 ]
Iancu, Madalina [4 ]
Badea, Gabriela [4 ]
Boukherroub, Rabah [5 ]
Ogale, Satishchandra [2 ]
Szunerits, Sabine [5 ]
机构
[1] Polish Acad Sci, Inst Anim Reprod & Food Res, Tuwima 10, PL-10748 Olsztyn, Poland
[2] IISER, Pune 411008, Maharashtra, India
[3] Int Ctr Biodynam, 1B Intrarea Portocalelor,Sect 6, Bucharest 060101, Romania
[4] Agrippa Ionescu Emergency Clin Hosp, 7 Ion Mincu, Bucharest, Romania
[5] Univ Valenciennes, Univ Lille, CNRS, Cent Lille,ISEN,IEMN,UMR 8520, F-59000 Lille, France
来源
ACS OMEGA | 2018年 / 3卷 / 09期
关键词
BRAIN NATRIURETIC PEPTIDE; PRINTED CARBON ELECTRODES; TROPONIN-I; ENZYME-IMMUNOASSAY; DNA APTAMER; NT-PROBNP; DEPOSITION; DIAGNOSIS; SERUM; BNP;
D O I
10.1021/acsomega.8b01558
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Rapid and accurate diagnostic technologies for early-state identification of cardiovascular abnormalities have become of high importance to prevent and attenuate their progression. The capability of biosensors to determine an increase in the concentration of cardiovascular protein biomarkers in circulating blood immediately after a myocardial infarction makes them ideal point-of-care platforms and alternative approaches to electrocardiograms, chest X-rays, and different laboratory-based immunoassays. We report here a generic approach toward multianalyte sensing platforms for cardiac biomarkers by developing aptamer-based electrochemical sensors for brain natriuretic peptide (BNP-32) and cardiac troponin I (cTnI). For this, commercial gold-based screen-printed electrodes were modified electrophoretically with polyethyleneimine/reduced graphene oxide films. Covalent grafting of propargylacetic acid integrates propargyl groups onto the electrode to which azide-terminated aptamers can be immobilized using Cu(I)-based "click" chemistry. To ensure low biofouling and high specificity, cardiac sensors were modified with pyrene anchors carrying poly(ethylene glycol) units. In the case of BNP-32, the sensor developed has a linear response from 1 pg mL(-1) to 1 mu g mL(-1) in serum; for cTnI, linearity is observed from 1 pg mL(-1) to 10 ng mL(-1) as demanded for early-stage diagnosis of heart failure. These electrochemical aptasensors represent a step further toward multianalyte sensing of cardiac biomarkers.
引用
收藏
页码:12010 / 12018
页数:9
相关论文
共 33 条
  • [1] Cardiovascular disease detection using bio-sensing techniques
    Altintas, Zeynep
    Fakanya, Wellington M.
    Tothill, Ibtisam E.
    [J]. TALANTA, 2014, 128 : 177 - 186
  • [2] Preliminary development of a DNA aptamer-magnetic bead capture electrochemiluminescence sandwich assay for brain natriuretic peptide
    Bruno, John G.
    Richarte, Alicia M.
    Phillips, Taylor
    [J]. MICROCHEMICAL JOURNAL, 2014, 115 : 32 - 38
  • [3] Sensitive electrochemical detection of cardiac troponin I in serum and saliva by nitrogen-doped porous reduced graphene oxide electrode
    Chekin, Fereshteh
    Vasilescu, Alina
    Jijie, Roxana
    Singh, Santosh K.
    Kurungot, Sreekumar
    Iancu, Madalina
    Badea, Gabriela
    Boukherroub, Rabah
    Szunerits, Sabine
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 180 - 187
  • [4] Two-step process for programmable removal of oxygen functionalities of graphene oxide: functional, structural and electrical characteristics
    Dave, Kashyap
    Park, Kyung Hee
    Dhayal, Marshal
    [J]. RSC ADVANCES, 2015, 5 (116) : 95657 - 95665
  • [5] Multiplexed Point-of-Care Testing - xPOCT
    Dincer, Can
    Bruch, Richard
    Kling, Andre
    Dittrich, Petra S.
    Urban, Gerald A.
    [J]. TRENDS IN BIOTECHNOLOGY, 2017, 35 (08) : 728 - 742
  • [6] Multiplexed Determination of Amino-Terminal Pro-BType Natriuretic Peptide and C-Reactive Protein Cardiac Biomarkers in Human Serum at a Disposable Electrochemical Magnetoimmunosensor
    Esteban-Fernandez de Avila, Berta
    Escamilla-Gomez, Vanessa
    Lanzone, Valentina
    Campuzano, Susana
    Pedrero, Maria
    Compagnone, Dario
    Pingarron, Jose M.
    [J]. ELECTROANALYSIS, 2014, 26 (02) : 254 - 261
  • [7] Improved LFIAs for highly sensitive detection of BNP at point-of-care
    Gong, Yan
    Hu, Jie
    Choi, Jane Ru
    You, Minli
    Zheng, Yamin
    Xu, Bo
    Wen, Ting
    Xu, Feng
    [J]. INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 4455 - 4465
  • [8] Recent Development of Cardiac Troponin I Detection
    Han, Xu
    Li, Shanghao
    Peng, Zhili
    Othman, Abdelhameed M.
    Leblanc, Roger
    [J]. ACS SENSORS, 2016, 1 (02): : 106 - 114
  • [9] Polymer-modified microfluidic immunochip for enhanced electrochemical detection of troponin I
    Horak, Josef
    Dincer, Can
    Qelibari, Edvina
    Bakirci, Hueseyin
    Urban, Gerald
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 478 - 485
  • [10] Prognostic value of B-type natriuretic peptide and its amino-terminal proBNP fragment for cardiovascular events with stratification by renal function
    Horii, Manabu
    Matsumoto, Takaki
    Uemura, Shiro
    Sugawara, Yu
    Takitsume, Akihiro
    Ueda, Tomoya
    Nakagawa, Hitoshi
    Nishida, Taku
    Soeda, Tsunenari
    Okayama, Satoshi
    Somekawa, Satoshi
    Ishigami, Kenichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Kawakami, Rika
    Saito, Yoshihiko
    [J]. JOURNAL OF CARDIOLOGY, 2013, 61 (5-6) : 410 - 416