Introduction: There has been a debate on the use of ceramic-on-ceramic coupling with the retained femoral stem in isolated acetabular revision. The purpose of this study was to retrospectively review the results and complications of isolated revision of the acetabular component using alumina-on-alumina bearings. Methods: Between August 2010 and December 2013, 22 patients (23 hips) with a mean age of 60.74 years (40-73) underwent isolated revision of the acetabular component from metal-on-polyethylene to alumina-on-alumina bearings without using a metal sleeve on the undamaged trunnion. All patients completed clinical and radiographic evaluation. Results: At a mean follow-up of 3 years (2-5.5), all patients had a significant improvement in the clinical outcome, including Harris Hip Score (84.9 vs. 43, p < 0.001), West Ontario McMaster University Osteoarthritis Index Score (14.4 vs. 49.2, p < 0.001), and visual analogue pain score (1.42 vs. 6.63, p < 0.001). Complications included one aseptic loosening of the acetabular component and three noisy hips (click only). No fracture of the ceramic bearings, dislocation, infection, or squeaking noise were observed in any of the patients. Conclusion: Isolated revision of the acetabular component to alumina-on-alumina bearings on the undamaged trunnion may be considered if there is no available titanium sleeves. Our study showed a satisfactory early outcome with minimal complications. However, a longer term follow-up study is necessary.
引用
收藏
页数:7
相关论文
共 44 条
[1]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[2]  
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[3]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[4]   Third-Generation Ceramic-on-Ceramic Bearing Surfaces in Revision Total Hip Arthroplasty [J].
Chang, Jun-Dong ;
Kamdar, Rutuj ;
Yoo, Je-Hyun ;
Hur, Mina ;
Lee, Sang-Soo .
JOURNAL OF ARTHROPLASTY, 2009, 24 (08) :1231-1235
[5]   Ceramic-on-Ceramic Total Hip Arthroplasty: Minimum of Six-Year Follow-up Study [J].
Choy, Won-Sik ;
Kim, Kap Jung ;
Lee, Sang Ki ;
Bae, Kyoung Wan ;
Hwang, Yoon Sub ;
Park, Chang Kyu .
CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (03) :174-179
[6]  
CONN R A, 1985, Orthopaedic Transactions, V9, P451
[7]   Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171
[8]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]  
EFTEKHAR NS, 1976, CLIN ORTHOP RELAT R, P120
[10]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55