Cup-to-disc ratio:: agreement between slit-lamp indirect ophthalmoscopic estimation and stratus optical coherence tomography measurement

被引:34
作者
Arnalich-Montiel, F. [1 ]
Munoz-Negrete, F. J. [1 ]
Rebolleda, G. [1 ]
Sales-Sanz, M. [1 ]
Cabarga, C. [1 ]
机构
[1] Hosp Ramon & Cajal, Dept Ophthalmol, Glaucoma Unit, E-28034 Madrid, Spain
关键词
D O I
10.1038/sj.eye.6702391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine agreement between slit-lamp indirect ophthalmoscopy and Stratus optical coherence tomography (OCT) when assessing cup-to-disc ratios (CDRs). Methods Twenty-five ocular hypertensive subjects and 56 patients with primary open-angle glaucoma were included. Estimation of vertical (VCDR) and horizontal (HCDR) cup-to-disc ratio with slit-lamp ophthalmoscopy was made by three glaucoma specialists along with OCT scanning of optic nerve head. Agreement between OCT and specialists was measured by intraclass correlation coefficients (ICC), Bland and Altman's scatterplots, and a regression coefficient of the average difference. Results The mean VCDR and HCDR was significantly higher (P < 0.001) with OCT than that estimated by the specialists, with the difference ranging from 0.08 to 0.11, and from 0.13 to 0.18, respectively, depending on the specialist. Difference was higher (P < 0.001) for cuppings below 0.3, and looses significance for larger VCDR cuppings (above 0.7). ICC for VCDR was 0.87 among specialists, and ranges from 0.82 to 0.75 when comparing OCT and specialists. ICC for HCDR was 0.83 among specialists and 0.74 between OCT and specialists. When data were plotted according to the Bland - Altman method, as the cupping increased, the agreement also increased. Conclusions There is very good agreement among the specialists when estimating CDRs by stereoscopic slit-lamp biomicroscopy. OCT shows higher values than the specialists; the greatest differences occurred when assessing small CDRs and the differences diminished as the cupping increased. These two methods of measurement are not interchangeable, and the difference must be considered, especially in discs with smaller CDRs.
引用
收藏
页码:1041 / 1049
页数:9
相关论文
共 31 条
[11]   A comparison of cup-to-disc ratio measurement in normal subjects using optical coherence tomography image analysis of the optic nerve head and stereo fundus biomicroscopy [J].
Hrynchak, P ;
Hutchings, N ;
Jones, D ;
Simpson, T .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (06) :543-550
[12]   Comparing ophthalmoscopy, slide viewing, and semiautomated systems in optic disc morphometry [J].
Ikram, MK ;
Borger, PH ;
Assink, JJM ;
Jonas, JB ;
Hofman, A ;
de Jong, PTVM .
OPHTHALMOLOGY, 2002, 109 (03) :486-493
[13]   Detection of incident field loss using the glaucoma hemifield test [J].
Katz, J ;
Quigley, HA ;
Sommer, A .
OPHTHALMOLOGY, 1996, 103 (04) :657-663
[14]   Analysis of retinal nerve fiber layer and optic nerve head in glaucoma with different reference plane offsets, using optical coherence tomography [J].
Leung, CKS ;
Chan, WM ;
Hui, YL ;
Yung, WH ;
Woo, J ;
Tsang, MK ;
Tse, KK .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (03) :891-899
[15]  
Lichter P R, 1976, Trans Am Ophthalmol Soc, V74, P532
[16]   Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Vessani, RM ;
Susanna, R ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :44-55
[17]   Assessment of optic disc anatomy and nerve fiber layer thickness in ocular hypertensive subjects with normal short-wavelength automated perimetry [J].
Mistlberger, A ;
Liebmann, JM ;
Greenfield, DS ;
Hoh, ST ;
Ishikawa, H ;
Marmor, M ;
Ritch, R .
OPHTHALMOLOGY, 2002, 109 (07) :1362-1366
[18]   Identifying early glaucoma with optical coherence tomography [J].
Nouri-Mahdavi, K ;
Hoffman, D ;
Tannenbaum, DP ;
Law, SK ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) :228-235
[19]   Evaluation of the influence of tilt of optic disc on the measurement of optic disc variables obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy [J].
Park, CY ;
Kim, YT ;
Kee, C .
JOURNAL OF GLAUCOMA, 2005, 14 (03) :210-214
[20]   Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT [J].
Paunescu, LA ;
Schuman, JS ;
Price, LL ;
Stark, PC ;
Beaton, S ;
Ishikawa, H ;
Wollstein, G ;
Fujimoto, JG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1716-1724