Outcomes of Oversized Coronary Stenting in Patients Undergoing Elective Percutaneous Coronary Intervention

被引:0
作者
Alemzadeh-Ansari, Mohammad Javad [1 ]
Kyavar, Majid [1 ]
Khalesi, Somayeh [1 ]
Oalouchi, Saeid [1 ]
Noohi, Feridoun [1 ]
Maleki, Majid [1 ]
Peighambari, Mohamad Mehdi [1 ]
Firouzi, Ata [1 ]
Mohebbi, Bahram [1 ]
Zahedmehr, Ali [1 ]
Rashidinejad, Alireza [1 ]
Shakerian, Farshad [1 ]
Kiani, Reza [1 ]
Khalili, Yasaman [1 ]
机构
[1] Iran Univ Med Sci, Cardiovasc Intervent Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
来源
IRANIAN HEART JOURNAL | 2021年 / 22卷 / 02期
关键词
Stable angina; Percutaneous coronary intervention; Stent; Major adverse cardiac event; STABLE ANGINA-PECTORIS; INTRAVASCULAR ULTRASOUND; BALLOON ANGIOPLASTY; IMPLANTATION; PLACEMENT; DISEASE; IMPACT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The size of the coronary stent has an important role in the efficacy of stenting and its complications. The present study focused on the clinical outcomes of undersized, normal-sized, and oversized stenting. Methods: This historical cohort study, conducted from April 2016 to March 2017 at Rajaie Cardiovascular Medical and Research Center, analyzed the results of elective percutaneous coronary intervention (PCI) and angiography on patients who met the inclusion criteria. Based on the ratio between the stent and the reference vessel, the patients were divided into 3 groups: undersized stenting (stent diameter/reference vessel diameter <0.9), normal-sized stenting (ratio=0.9-1), and oversized stenting (ratio>1). Data on demographic characteristics, procedural characteristics, underlying diseases, the hospital length of stay, major adverse cardiac events (MACE), post-PCI restenosis, stent thrombosis, and post-PCI cerebrovascular accident were extracted from the patients' files and entered into a checklist. Results: Oversized stenting significantly reduced the incidence of MACE 1 year after PCI compared with undersized and normal-sized stenting. The incidence of rehospitalization for acute coronary syndrome was 7.5 times lower in oversized stenting than in undersized stenting (P=0.002). The incidence of re-PCI on the involved vessel decreased significantly with an increase in the stent size (P=0.017). Additionally, there was no incidence of stent restenosis in oversized stenting (P=0.001). The other outcomes had no significant correlation with the stent size. Conclusions: Based on the results of our study, oversized stenting could improve clinical outcomes.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 17 条
[1]   Unstable Angina: Is It Time for a Requiem? [J].
Braunwald, Eugene ;
Morrow, David A. .
CIRCULATION, 2013, 127 (24) :2452-2457
[2]   Coronary stenting: why size matters [J].
De Benedetti, Edoardo ;
Urban, Philip .
HEART, 2007, 93 (12) :1500-1501
[3]   Impact of Ultrasound Attenuation and Plaque Rupture as Detected by Intravascular Ultrasound on the Incidence of No-Reflow Phenomenon After Percutaneous Coronary Intervention in ST-Segment Elevation Myocardial Infarction [J].
Endo, Mitsuaki ;
Hibi, Kiyoshi ;
Shimizu, Tomoaki ;
Komura, Naohiro ;
Kusama, Ikuyoshi ;
Otsuka, Fumiyuki ;
Mitsuhashi, Takayuki ;
Iwahashi, Noriaki ;
Okuda, Jun ;
Tsukahara, Kengo ;
Kosuge, Masami ;
Ebina, Toshiaki ;
Umemura, Satoshi ;
Kimura, Kazuo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) :540-549
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   Growing Epidemic of Coronary Heart Disease in Low- and Middle-Income Countries [J].
Gaziano, Thomas A. ;
Bitton, Asaf ;
Anand, Shuchi ;
Abrahams-Gessel, Shafika ;
Murphy, Adrianna .
CURRENT PROBLEMS IN CARDIOLOGY, 2010, 35 (02) :72-115
[6]   Coronary angioplasty with or without stent implantation for acute myocardial infarction [J].
Grines, CL ;
Cox, DA ;
Stone, GW ;
Garcia, E ;
Mattos, LA ;
Giambartolomei, A ;
Brodie, BR ;
Madonna, O ;
Eijgelshoven, M ;
Lansky, AJ ;
O'Neill, WW ;
Morice, MC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (26) :1949-1956
[7]  
Hermiller JB, 1994, INVASCULAR DIAGNOSTI, P267, DOI [10.1002/ccd.1810250207, DOI 10.1002/CCD.1810250207]
[8]   Association between preprocedural hemoglobin level and 1-year outcome of elective percutaneous coronary intervention [J].
Hosseini, Seyed Kianoosh ;
Ansari, Mohammad Javad Alemzadeh ;
Tokaldany, Masoumeh Lotfi ;
Sharafi, Ahmad ;
Kazazi, Elham Hakki ;
Poorhosseini, Hamidreza .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (04) :331-335
[9]   Impact of Stent Size Selection on Acute and Long-Term Outcomes After Drug-Eluting Stent Implantation in De Novo Coronary Lesions [J].
Kitahara, Hideki ;
Okada, Kozo ;
Kimura, Takumi ;
Yock, Paul G. ;
Lansky, Alexandra J. ;
Popma, Jeffrey J. ;
Yeung, Alan C. ;
Fitzgerald, Peter J. ;
Honda, Yasuhiro .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (10)
[10]  
Martín JJA, 2005, REV ESP CARDIOL, V58, P198