Rapid classification and quantification of cocaine in seized powders with ATR-FTIR and chemometrics

被引:39
作者
Eliaerts, Joy [1 ,2 ]
Dardenne, Pierre [3 ]
Meert, Natalie [1 ]
Van Durme, Filip [1 ]
Samyn, Nele [1 ]
Janssens, Koen [2 ]
De Wael, Karolien [2 ]
机构
[1] Natl Inst Criminalist & Criminol, Dept Toxicol & Drugs, Brussels, Belgium
[2] Univ Antwerp, Chem Dept, AXES Res Grp, Antwerp, Belgium
[3] Walloon Agr Res Ctr, Gembloux, Belgium
关键词
cocaine; ATR-FTIR; chemometrics; classification; quantification; SVM; PLS; SUPPORT VECTOR MACHINES; PARTIAL LEAST-SQUARES; INFRARED-SPECTROSCOPY; REGRESSION; COMPONENT; DISCRIMINATION; ADULTERANTS; VALIDATION; MIXTURES; TUTORIAL;
D O I
10.1002/dta.2149
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditionally, fast screening for the presence of cocaine in unknown powders is performed by means of colour tests. The major drawbacks of these tests are subjective colour evaluation depending on the operator (50 shades of blue') and a lack of selectivity. An alternative fast screening technique is Fourier Transform InfraRed (FTIR) spectrometry. This technique provides spectra that are difficult to interpret without specialized expertise and shows a lack of sensitivity for the detection of cocaine in mixtures. To overcome these limitations, a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling was combined with a multivariate technique, called Support Vector Machines (SVM). Representative street drug powders (n=482), seized during the period January 2013 to July 2015, and reference powders (n=33) were used to build and validate a classification model (n=515) and a quantification model (n=378). Both models were compared with the conventional chromatographic techniques. The SVM classification model showed a high sensitivity, specificity, and efficiency (99%). The SVM quantification model determined cocaine content with a root mean squared error of prediction (RMSEP) of 6% calculated over a wide working range from 4 to 99 w%. In conclusion, the developed models resulted in a clear output (cocaine detected or cocaine not detected) and a reliable estimation of the cocaine content in a wide variety of mixtures. The ATR-FTIR technique combined with SVM is a straightforward, user-friendly, and fast approach for routine classification and quantification of cocaine in seized powders. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:1480 / 1489
页数:10
相关论文
共 35 条
[1]  
[Anonymous], 2015, EUR DRUG REP
[2]  
[Anonymous], 2007, APPL CHEMOMETRICS SC
[3]  
[Anonymous], E165505 ASTM
[4]  
[Anonymous], 2000, NATURE STAT LEARNING, DOI DOI 10.1007/978-1-4757-3264-1
[5]  
[Anonymous], 2005, General requirements for the competence of testing and calibration laboratories
[6]   Partial least squares for discrimination [J].
Barker, M ;
Rayens, W .
JOURNAL OF CHEMOMETRICS, 2003, 17 (03) :166-173
[7]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[8]  
Chih-Wei Hsu, 2016, PRACTICAL GUIDE SUPP
[9]   Least-squares support vector machines for chemometrics: an introduction and evaluation [J].
Cogdill, RP ;
Dardenne, P .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (02) :93-100
[10]  
Fearn T., 1996, NIR news, V7, P5, DOI DOI 10.1255/NIRN.378