Measurement of cardiac output from a test-bolus injection in multislice computed tomography

被引:37
作者
Mahnken, AH
Klotz, E
Hennemuth, A
Jung, B
Koos, R
Wildberger, JE
Günther, RW
机构
[1] Rhein Westfal TH Aachen, Dept Radiol, D-52074 Aachen, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Med Clin 1, D-52074 Aachen, Germany
关键词
computed tomography; multi-detector row; heart; function;
D O I
10.1007/s00330-003-2054-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the feasibility of non-invasive determination of cardiac function from test-bolus data in multislice spiral computed tomography (MSCT). In 25 patients enhancement data gathered from a standardized test-bolus injection were analyzed. The test-bolus examination was performed prior to a retrospectively ECG-gated MSCT of the heart. A time-attenuation curve was obtained in the ascending aorta at the level of the pulmonary arteries. A gamma variate fit was applied to the curve in order to exclude recirculation and get pure first-pass data. Using the known amount of iodine injected, cardiac output (CO), and stroke volume (SV) were determined from integration of the fitted contrast enhancement curve using a reformation of the Stewart-Hamilton equation. Results were compared with CO and SV calculated from the geometric analysis of the retrospectively gated MSCT data using the ARGUS Software (Siemens, Forchheim, Germany). The CO and SV determined from test-bolus analysis and from geometric analysis correlated well with Pearson's correlation coefficients of 0.87 and 0.88, respectively. The standard deviation of the difference between both methods was 0.51 l/min for CO (8.6%) and 11.0 ml for SV (12.3%). Non-invasive quantification of CO seems to be feasible from a standard test-bolus injection. It provides valuable information on cardiac function without additional radiation or application of contrast material.
引用
收藏
页码:2498 / 2504
页数:7
相关论文
共 37 条
[1]   Accurate measures of left ventricular ejection fraction using electron beam tomography: A comparison with radionuclide angiography, and cine angiography [J].
Baik, HK ;
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Brundage, BH .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05) :391-398
[2]   COMPARISON OF AN IONIC WITH A NONIONIC CONTRAST AGENT FOR CARDIAC ANGIOGRAPHY - RESULTS OF A MULTICENTER TRIAL [J].
BETTMANN, MA ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1985, 20 (01) :S70-S74
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BONOW RO, 1992, CIRCULATION, V86, P338
[5]   Advances in noninvasive cardiac output monitoring: An update [J].
Botero, M ;
Lobato, EB .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (05) :631-640
[6]   CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[7]   Parameters affecting bolus geometry in CTA: A review [J].
Cademartiri, F ;
van der Lugt, A ;
Luccichenti, G ;
Pavone, P ;
Krestin, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) :598-607
[8]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[9]   A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage [J].
Flohr, T ;
Prokop, M ;
Becker, C ;
Schoepf, UJ ;
Kopp, AF ;
White, RD ;
Schaller, S ;
Ohnesorge, B .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1497-1503
[10]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923