Real-time tracking and shape analysis of atrial septal defects in 3D echocardiography

被引:9
作者
Linguraru, Marius George [1 ]
Kabla, Alexandre
Marx, Gerald R.
del Nido, Pedro J.
Howe, Robert D.
机构
[1] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[2] NIH, Diagnost Radiol Dept, Bethesda, MD 20892 USA
[3] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[4] Harvard Univ, Sch Med, Childrens Hosp, Dept Cardiol, Boston, MA USA
[5] Harvard Univ, Sch Med, Childrens Hosp, Dept Cardiac Surg, Boston, MA USA
关键词
echocardiography; real time; atrial septal defect; tracking; segmentation; dynamic morphology;
D O I
10.1016/j.acra.2007.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
beating heart procedures. Our application assists pediatric atrial septal defect (ASD) closure techniques using real-time 3D US guidance and rigid instruments. ASD tracking is also an important tool for facilitating systematic clinical studies of the dynamic behavior of the intra-atrial communication. One major image processing challenge is associated with the required processing of information at high frame rate, especially given the low image quality. Materials and Methods. We present an optimization scheme for a block flow technique, which combines the probability-based velocity computation for an entire block (a 3D volume centered on the ASD) with cyclic template matching. The adapted similarity imposes constraints both locally (from frame to frame) to conserve energy, and globally (from a reference template) to minimize cumulative errors. The algorithm is optimized for fast and reliable results. For tests, we use three intra-operational 4D ultrasound sequences of clinical infant beating hearts with ASD. Results. Computing velocity at the block level with an optimized scheme, our technique tracks ASD motion at a frequency of 60 frames/s on clinical 4D datasets. Results are stable and accurate for changes in resolution and block size. In particular, we show robust real-time tracking and preliminary segmentation results of the ASD shape, size and orientation as a function of time. Conclusions. We present an optimized block flow technique for real-time tracking of ASD to assist in minimally invasive beating heart surgery. Our method proposes the standard use of references for processing repetitive data. This paper represents, to our knowledge, the first study on the dynamic morphology of ASD that takes into account the angular effect introduced by the slanted position of the intra-atrial communication with respect to the US probe.
引用
收藏
页码:1298 / 1309
页数:12
相关论文
共 30 条
[1]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[2]  
Boukerroui D, 2003, LECT NOTES COMPUT SC, V2732, P586
[3]  
Cannon Jeremy W, 2003, Comput Aided Surg, V8, P82, DOI 10.3109/10929080309146042
[4]   3-D correlation-based speckle tracking [J].
Chen, X ;
Xie, H ;
Erkamp, R ;
Kim, K ;
Jia, C ;
Rubin, JM ;
O'Donnell, M .
ULTRASONIC IMAGING, 2005, 27 (01) :21-36
[5]   New maximum likelihood motion estimation schemes for noisy ultrasound images [J].
Cohen, B ;
Dinstein, I .
PATTERN RECOGNITION, 2002, 35 (02) :455-463
[6]   USING CANNY CRITERIA TO DERIVE A RECURSIVELY IMPLEMENTED OPTIMAL EDGE DETECTOR [J].
DERICHE, R .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (02) :167-187
[7]  
Downing SW, 2002, HEART SURG FORUM, V5, P96
[8]   Evaluation of optical flow algorithms for tracking endocardial surfaces on three-dimensional ultrasound data [J].
Duan, Q ;
Angelini, ED ;
Herz, SL ;
Ingrassia, CM ;
Gerard, O ;
Costa, KD ;
Holmes, JW ;
Laine, AF .
MEDICAL IMAGING 2005: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2005, 5750 :159-169
[9]  
FAELLA JH, 2003, J INTERV CARDIOL, V16, P393
[10]   Three-dimensional ultrasound imaging [J].
Fenster, A ;
Downey, DB ;
Cardinal, HN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :R67-R99