Amperometric ascorbate sensor based on conducting polymer:: Poly(N-methylaniline) versus polyaniline

被引:34
作者
Brazdziuvien, K. [1 ]
Jureviciute, I. [1 ]
Malinauskas, A. [1 ]
机构
[1] Inst Chem, LT-01108 Vilnius, Lithuania
关键词
ascorbate sensor; electrocatalysis; polyaniline; poly(N-methylaniline); electroanalysis;
D O I
10.1016/j.electacta.2007.07.054
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Electrocatalytic oxidation of ascorbate (vitamin C) at poly (N-methyl aniline) modified electrode has been studied and compared with that proceeding at polyaniline modified sensor. A sigmoid-shaped anodic current transient as a response to addition of ascorbate was found for polyaniline modified electrode in pH-neutral solution, whereas a 'normal-shaped' current transient was found to be characteristic for poly(N-methylaniline) modified electrode. Based on this, a hypothesis on the autocatalytic mechanism for electrochemical oxidation of ascorbate was confirmed. It has been shown that poly(N-methlaniline) modified electrode can be used as an amperometric ascorbate sensor, operating in slightly acidic or pH-neutral buffer solutions at a controlled potential of 0.1-0.5 V versus Ag/AgCl, and the dependencies of current response on ascorbate concentration, the thickness of a polymer layer, and operating potential have been analyzed. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 27 条
[1]   Non-spectrophotometric methods for the determination of Vitamin C [J].
Arya, SP ;
Mahajan, M ;
Jain, P .
ANALYTICA CHIMICA ACTA, 2000, 417 (01) :1-14
[2]  
Bagheri A, 1997, ANAL LETT, V30, P2023, DOI 10.1080/00032719708001718
[3]   ALTERATION OF THE ION-EXCHANGE MECHANISM OF AN ELECTROACTIVE POLYMER BY MANIPULATION OF THE ACTIVE-SITE - PROBE BEAM DEFLECTION AND QUARTZ CRYSTAL MICROBALANCE STUDY OF POLY(ANILINE) AND POLY(N-METHYLANILINE) [J].
BARBERO, C ;
MIRAS, MC ;
HAAS, O ;
KOTZ, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 310 (1-2) :437-443
[4]   The oxidation of ascorbate at poly(aniline)-poly(vinylsulfonate) composite coated electrodes [J].
Bartlett, PN ;
Wallace, ENK .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2001, 3 (08) :1491-1496
[5]  
Berg J.M., 2015, Oxidative Phosphorylation, Veight
[6]   Electrocatalysis of ascorbic acid ion the glassy carbon electrode chemically modified with polyaniline films [J].
Casella, IG ;
Guascito, MR .
ELECTROANALYSIS, 1997, 9 (18) :1381-1386
[7]   CHEMICAL AND ELECTROCHEMICAL SYNTHESIS AND CHARACTERIZATION OF POLYDIPHENYLAMINE AND POLY-N-METHYLANILINE [J].
COMISSO, N ;
DAOLIO, S ;
MENGOLI, G ;
SALMASO, R ;
ZECCHIN, S ;
ZOTTI, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 255 (1-2) :97-110
[8]   Investigation and comparison of the electrochemical behavior of some organic and biological molecules at various conducting polymer electrodes [J].
Erdogdu, G ;
Karagozler, AE .
TALANTA, 1997, 44 (11) :2011-2018
[9]  
Erdogdu G, 1996, ANAL LETT, V29, P221
[10]   A KINETIC-STUDY OF THE REACTION BETWEEN DIHYDRONICOTINAMIDE ADENINE-DINUCLEOTIDE (NADH) AND AN ELECTRODE MODIFIED BY ADSORPTION OF 1,2-BENZOPHENOXAZINE-7-ONE [J].
GORTON, L ;
JOHANSSON, G ;
TORSTENSSON, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 196 (01) :81-92