Fast Spin-Echo Triple Echo Dixon: Initial Clinical Experience With a Novel Pulse Sequence for Simultaneous Fat-Suppressed and Nonfat-Suppressed T2-Weighted Spine Magnetic Resonance Imaging

被引:32
|
作者
Low, Russell N. [1 ,2 ]
Austin, Matthew J. [3 ]
Ma, Jingfei [4 ]
机构
[1] Sharp & Childrens MRI Ctr, San Diego, CA 92123 USA
[2] San Diego Imaging Med Grp, San Diego, CA 92123 USA
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
MR imaging; 2-point Dixon; fat suppression; INVERSION-RECOVERY; PHASE-CORRECTION; WATER; EFFICIENT; SEPARATION; IDEAL; MRI; DECOMPOSITION; PROTON;
D O I
10.1002/jmri.22453
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a prototype fast spin-echo (FSE) triple-echo Dixon (FTED) technique for T2-weighted spine imaging with and without fat suppression compared to conventional T2-weighted fast recovery (FR) FSE and short-tau inversion recovery (STIR) imaging. Materials and Methods: Sixty-one patients were referred for spine magnetic resonance imaging (MRI) including sagittal FTED (time 2:26), STIR (time 2:42), and T2 FRFSE (time 2:55). Two observers compared STIR and VIED water images and T2 FRFSE and FTED T2 images for overall image quality, fat suppression, anatomic sharpness, motion, cerebrospinal fluid (CSF) flow artifact, susceptibility, and disease depiction. Results: On FTED images water and fat separation was perfect in 58 (.95) patients. Compared to STIR, the FTED water images demonstrated less motion in 57 (.93) of 61 patients (P < 0.05), better anatomic sharpness in 51 (.84) and patients (P < 0.05), and less CSF flow artifact in 7 (.11) P < 0.05) patients. There was no difference in fat suppression or chemical shift artifact. T2 FRFSE and FTED T2 images showed equivalent motion, CSF flow, and chemical shift artifact. Lesion depiction was equivalent on FTED water and STIR images and FTED T2 and T2 FRFSE images. Conclusion: FTED efficiently provides both fat-suppressed and nonfat-suppressed T2-weighted spine images with excellent image quality, equal disease depiction, and 56% reduction in scan time compared to conventional STIR and T2 FRFSE.
引用
收藏
页码:390 / 400
页数:11
相关论文
共 37 条
  • [21] Extending slice coverage for breathhold fat-suppressed T2-weighted liver at 3.OT: Application,past spin-echo of the of variable-rate selective-excitation (VERSE) RF pulses
    van den Bos, Indra C.
    Hussain, Shahid M.
    Krestin, Gabriel P.
    Wielopolski, Piotr A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) : 110 - 116
  • [22] Comparison of inversion recovery fast spin-echo (FSE) with T2-weighted fat-saturated FSE and T1-weighted MR imaging in bone marrow lesion detection
    Pui, MH
    Chang, SK
    SKELETAL RADIOLOGY, 1996, 25 (02) : 149 - 152
  • [23] Magnetic resonance imaging of the cranial nerves in the posterior fossa:: A comparative study of T2-weighted spin-echo sequences at 1.5 and 3.0 tesla
    Fischbach, F.
    Mueller, M.
    Bruhn, H.
    ACTA RADIOLOGICA, 2008, 49 (03) : 358 - 363
  • [24] Relaxivity Optimization of a PEGylated Iron-Oxide-Based Negative Magnetic Resonance Contrast Agent for T2-Weighted Spin-Echo Imaging
    Poeselt, Elmar
    Kloust, Hauke
    Tromsdorf, Ulrich
    Janschel, Marcus
    Hahn, Christoph
    Masslo, Christoph
    Weller, Horst
    ACS NANO, 2012, 6 (02) : 1619 - 1624
  • [25] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Tanaka, Utaru
    Ueno, Yoshiko
    Morinaga, Yukiko
    Miyake, Hideaki
    Kyotani, Katsusuke
    Ueda, Yu
    Kitajima, Kazuhiro
    Sofue, Keitaro
    Suenaga, Yuko
    Sugimura, Kazuro
    Takahashi, Satoru
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 707 - 717
  • [26] Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo
    Ichinohe, Fumihito
    Oyama, Kazuki
    Yamada, Akira
    Hayashihara, Hayato
    Adachi, Yasuo
    Kitoh, Yoshihiro
    Kanki, Yusuke
    Maruyama, Katsuya
    Nickel, Marcel Dominik
    Fujinaga, Yasunari
    INVESTIGATIVE RADIOLOGY, 2023, 58 (06) : 373 - 379
  • [27] Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction
    Asbach, P
    Klessen, C
    Kroencke, TJ
    Kluner, C
    Stemmer, A
    Hamm, B
    Taupitz, M
    MAGNETIC RESONANCE IMAGING, 2005, 23 (09) : 939 - 945
  • [28] Forensic age estimation via 3-T magnetic resonance imaging of ossification of the proximal tibial and distal femoral epiphyses: Use of a T2-weighted fast spin-echo technique
    Ekizoglu, Oguzhan
    Hocaoglu, Elif
    Inci, Ercan
    Can, Ismail Ozgur
    Aksoy, Sema
    Kazimoglu, Cemal
    FORENSIC SCIENCE INTERNATIONAL, 2016, 260 : 102.e1 - 102.e7
  • [29] Texture Analysis of Fat-Suppressed T2-Weighted Magnetic Resonance Imaging and Use of Machine Learning to Discriminate Nasal and Paranasal Sinus Small Round Malignant Cell Tumors
    Chen, Chen
    Qin, Yuhui
    Cheng, Junying
    Gao, Fabao
    Zhou, Xiaoyue
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [30] Free-breathing BLADE fat-suppressed T2 weighted turbo spin echo sequence for distinguishing lung cancer from benign pulmonary nodules or masses: A pilot study
    Dang, Shan
    Ma, Guangming
    Duan, Haifeng
    Han, Dong
    Yang, Qi
    Yu, Nan
    Yu, Yong
    Duan, Xiaoyi
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 79 - 85