Laparoscopic spray application of fibrin sealant effects on hemodynamics and spray efficiency at various application pressures and distances

被引:11
作者
Druckrey-Fiskaaen, K. T.
Janssen, M. W. W.
Omidi, L.
Polze, N.
Kaisers, U.
Nur, I.
Goldberg, E.
Bokel, G.
Hauss, J.
Schoen, Michael R.
机构
[1] Univ Leipzig, Dept Visceral Transplantat Thorac & Vasc Surg, D-04103 Leipzig, Germany
[2] Charite, Dept Anesthesiol & Intens Care Med, D-13353 Berlin, Germany
[3] Omrix Biopharmaceut Ltd, MDA Blood Ctr, IL-52621 Tel Hashomer, Israel
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2007年 / 21卷 / 10期
关键词
fibrin sealant; hemodynamics; laparosocopic surgery; spray application;
D O I
10.1007/s00464-007-9235-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Laparoscopic resections of parenchymal organs are increasingly performed. However, little is known about the effects of laparoscopic fibrin sealant spray applications on intraabdominal pressure (IAP) and hemodynamics. Methods: Cardiac and pulmonary monitoring was performed via two central venous pressure lines in the thoracic and abdominal vena cava, a pulmonary artery catheter, and a peripheral artery line. Air was sprayed into the abdomen at pressures of 2, 3, and 4 bar for 30 s. According to the group, a valve on a trocar was open or closed. To optimize fibrin sealant application, the sealant was sprayed at three different application pressures (2, 2.5, and 3 bar) and distances (2, 3.5, and 5 cm). Results: All spray simulations caused a significant increase in the IAP. During the first 10 s of spraying, the IAP increase was 5 mmHg or less, but rose rapidly during the last 20 s of spraying. The IAP increase resulted in decreased pulmonary compliance. Pulmonary resistance and the central venous pressures of both the thoracic and abdominal vena cava increased. At application pressures of 3 and 4 bar, the IAP increase was greater than 2 bar of pressure, reaching IAP values exceeding 35 mmHg. Spray mist formation was primarily dependent on application pressure, whereas clot formation and surface coverage depended on both application pressure and distance. The best results were achieved with an application pressure of 2.5 bar and a distance of 5 cm from the surface. Conclusions: This study shows that fibrin sealants can be used safely in laparoscopic procedures. Keeping the spray periods short and allowing air to escape from the abdomen can minimize the IAP increase. According to our results, a laparoscopic spray application of fibrin sealant should start with an insutuation pressure of 10 mmHg, an application pressure of 2.5 bar, and an application distance of 5 cm with a valve on the trocar left open.
引用
收藏
页码:1750 / 1759
页数:10
相关论文
共 27 条
  • [1] Laparoscopic heminephrectomy using a new fibrin sealant powder
    Bishoff, JT
    Cornum, RL
    Perahia, B
    Seay, T
    Eliason, S
    Katus, M
    Morey, A
    Gresham, V
    Pusateri, A
    Murcin, LA
    Tuthill, D
    Friedman, S
    [J]. UROLOGY, 2003, 62 (06) : 1139 - 1143
  • [2] Systematic review of the use of fibrin sealant to minimize perioperative allogeneic blood transfusion
    Carless, PA
    Anthony, DM
    Henry, DA
    [J]. BRITISH JOURNAL OF SURGERY, 2002, 89 (06) : 695 - 703
  • [3] Laparoscopic liver resection
    Cherqui, D
    [J]. BRITISH JOURNAL OF SURGERY, 2003, 90 (06) : 644 - 646
  • [4] Laparoscopic liver resections:: A feasibility study in 30 patients
    Cherqui, D
    Husson, E
    Hammoud, R
    Malassagne, B
    Stéphan, F
    Bensaid, S
    Rotman, N
    Fagniez, PL
    [J]. ANNALS OF SURGERY, 2000, 232 (06) : 753 - 761
  • [5] Laparoscopic resection of the pancreas - A feasibility study of the short-term outcome
    Edwin, B
    Mala, T
    Mathisen, O
    Gladhaug, I
    Buanes, T
    Lunde, OC
    Soreide, O
    Bergan, A
    Fosse, E
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2004, 18 (03): : 407 - 411
  • [6] Farges Olivier, 2002, J Hepatobiliary Pancreat Surg, V9, P242, DOI 10.1007/s005340200026
  • [7] Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection:: a randomised prospective trial
    Frilling, A
    Stavrou, GA
    Mischinger, HJ
    de Hemptinne, B
    Rokkjaer, M
    Klempnauer, J
    Thörne, A
    Gloor, B
    Beckebaum, S
    Ghaffar, MFA
    Broelsch, CE
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2005, 390 (02) : 114 - 120
  • [8] Cardiopulmonary effects of the laparoscopic pneumoperitoneum in a porcine model of adult respiratory distress syndrome
    Greif, WM
    Forse, RA
    [J]. AMERICAN JOURNAL OF SURGERY, 1999, 177 (03) : 216 - 221
  • [9] Circulatory and respiratory complications of carbon dioxide insufflation
    Gutt, CN
    Oniu, T
    Mehrabi, A
    Schemmer, P
    Kashfi, A
    Kraus, T
    Büchler, MW
    [J]. DIGESTIVE SURGERY, 2004, 21 (02) : 95 - 105
  • [10] The effects of elevated intraabdominal pressure, hypercarbia, and positioning on the hemodynamic responses to laparoscopic colectomy in pigs
    Horvath, KD
    Whelan, RL
    Lier, B
    Viscomi, S
    Barry, L
    Buck, K
    Bessler, M
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1998, 12 (02): : 107 - 114