Application of nano-sized multi-template imprinted polymer for simultaneous extraction of polycyclic aromatic hydrocarbon metabolites in urine samples followed by ultra-high performance liquid chromatographic analysis

被引:35
作者
Chauhan, Abhishek [1 ,2 ]
Bhatia, Tejasvi [1 ,2 ]
Singh, Amarnath [4 ]
Saxena, Prem Narain [3 ]
Kesavchandran, C. [1 ,4 ]
Mudiam, Mohana Krishna Reddy [1 ,2 ]
机构
[1] CSIR, Indian Inst Toxicol Res, Acad Sci & Innovat Res AcSIR, Lucknow 226001, Uttar Pradesh, India
[2] CSIR, Indian Inst Toxicol Res, Analyt Chem Sect, Lucknow 226001, Uttar Pradesh, India
[3] CSIR, Indian Inst Toxicol Res, SEM Facil, Lucknow 226001, Uttar Pradesh, India
[4] CSIR, Indian Inst Toxicol Res, Div Epidemiol, Lucknow 226001, Uttar Pradesh, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 985卷
关键词
Polycyclic aromatic hydrocarbon metabolites; Multi-template imprinting approach; Nano-sized molecularly imprinted polymer; Precipitation polymerization; Ultra-high performance liquid chromatography; SOLID-PHASE MICROEXTRACTION; PRECIPITATION POLYMERIZATION; MICROSPHERES; EXPOSURE; WATER; PAHS; 1-HYDROXYPYRENE; FLUORESCENCE; MONODISPERSE; SEPARATION;
D O I
10.1016/j.jchromb.2015.01.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nano-sized molecularly imprinted polymer (nMIP) was synthesized through precipitation polymerization method and used it as solid phase extraction (SPE) sorbent for the selective and simultaneous extraction of hydroxylated metabolites of polycyclic aromatic hydrocarbons (PAHs) from urine followed by ultra-high performance liquid chromatography (UHPLC) analysis coupled with the fluorescent detector (FLD). Multi-template imprinting approach was used in the synthesis of nMIP by taking 1-naphthol, 9-phenanthrol and 9-hydroxyfluorene as templates, methacrylic acid (MAA) as a monomer, ethyleneglycoldimethacrylate (EGDMA) as a crosslinker and AIBN as an initiator. The synthesized nMIP exhibit the highest degree of binding affinity in comparison to non-imprinted polymer (NIP), and its binding affinity found to be in the range of 50-90% for all five metabolites tested. Method exhibits good linearity over a range of concentrations of metabolites with a R-2 value ranges from 0.9789 to 0.9921. Limit of detection CLOD) and limit of quantitation (LOQ) in urine samples were found to be in the range of 0.33-2.6 and 0.99-8 ng mL(-1), respectively. Precision study shows that intra and inter-day precision was found to be less than 10%. The application of nMIP as SPE sorbent offers an effective and selective affinity towards the PAH metabolite's and found to be an alternative to the conventional sorbent for PAH metabolite's extraction from the biological samples. The developed nMIP offers wide advantages like simultaneous determination of PAH metabolites with improved sensitivity and found to be cost-effective for the routine analysis. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 61 条
  • [1] ACGIH American Conference of Governmental Industrial Hygienists, 2001, Documentation of the Threshold Limit Values for Chemical Substances, V7th
  • [2] [Anonymous], 1998, FITN PURP AN METH LA
  • [3] Molecularly imprinted polymer-liquid chromatography/fluorescence for the selective clean-up of hydroxylated polycyclic aromatic hydrocarbons in soils
    Baltrons, Oriol
    Lopez-Mesas, Montserrat
    Palet, Cristina
    Le Derf, Franck
    Portet-Koltalo, Florence
    [J]. ANALYTICAL METHODS, 2013, 5 (22) : 6297 - 6305
  • [4] Detection of polycyclic aromatic hydrocarbon metabolites by high-pressure liquid chromatography after purification on immunoaffinity columns in urine from occupationally exposed workers
    Bentsen-Farmen, RK
    Botnen, IV
    Noto, H
    Jacob, J
    Ovrebo, S
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1999, 72 (03) : 161 - 168
  • [5] Recent advances in molecular imprinting technology: current status, challenges and highlighted applications
    Chen, Lingxin
    Xu, Shoufang
    Li, Jinhua
    [J]. CHEMICAL SOCIETY REVIEWS, 2011, 40 (05) : 2922 - 2942
  • [6] CUI MZ, 1995, INDOOR ENVIRON, V4, P306
  • [7] Simultaneous analysis of naphthols, phenanthrols, and 1-hydroxypyrene in urine as biomarkers of polycyclic aromatic hydrocarbon exposure:: intraindividual variance in the urinary metabolite excretion profiles caused by intervention with β-naphthoflavone induction in the rat
    Elovaara, E
    Väänänen, V
    Mikkola, J
    [J]. ARCHIVES OF TOXICOLOGY, 2003, 77 (04) : 183 - 193
  • [8] Dipyridamole recognition and controlled release by uniformly sized molecularly imprinted nanospheres
    Esfandyari-Manesh, Mehdi
    Javanbakht, Mehran
    Atyabi, Fatemeh
    Mohammadi, Ali
    Mohammadi, Somayeh
    Akbari-Adergani, Behrouz
    Dinarvand, Rassoul
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (08): : 1692 - 1699
  • [9] Urinary PAH metabolites as biomarkers of exposure in aquatic environments
    Fillmann, G
    Watson, GM
    Howsam, M
    Francioni, E
    Depledge, MH
    Readman, JW
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (09) : 2649 - 2656
  • [10] Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
    Garrido Frenich, Antonia
    Romero-Gonzalez, R.
    Martinez Vidal, Jose Luis
    Martinez Ocana, R.
    Baquero Feria, P.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (06) : 2043 - 2059