Effects of shading and blocking in linear Fresnel reflector field

被引:73
|
作者
Sharma, Vashi [1 ]
Nayak, Jayanta K. [1 ]
Kedare, Shireesh B. [1 ]
机构
[1] Indian Inst Technol, Dept Energy Sci & Engn, Bombay 400076, Maharashtra, India
关键词
Linear Fresnel reflector; Shading; Blocking; Cost of electricity; TANDEM CONCENTRATOR SYSTEM; SOLAR CONCENTRATOR; PARABOLIC TROUGH; OPTICAL DESIGN; COLLECTOR SYSTEM; MIRROR ELEMENTS; PERFORMANCE; ABSORBER; WIDTH; ENERGY;
D O I
10.1016/j.solener.2014.12.026
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In a linear Fresnel reflector field, parallel rows of reflectors in a collector direct the incident sun rays towards a common linear receiver. Some portion of reflector aperture remains unused due to end effect, inter-row shading and blocking. In addition to these factors, cosine effect, cleanliness factor, reflectivity of reflectors, intercept factor, transmissivity of receiver cover, reflectivity of secondary reflector, absorptivity of absorber tube and thermal losses are other factors that contribute to energy losses and thus affect net energy collection by the heat transfer fluid in the absorber, electricity generation and cost of electricity. Conventionally, the collectors are oriented either along North South or East West directions in most cases. However the energy collection, electricity generation and cost of electricity need to be found out for all possible collector-orientations lying between North South and East West. This can be used in designing collectors for places where the available land strip does not align with any of these two directions. In this work, explicit analytical expressions for energy losses due to cosine effect, end effect, shading and blocking are derived for any desired time interval as functions of length (L) and width (w) of aperture of reflector-row, spacing between adjacent reflector-rows (p), number of reflector-rows in a collector (n), height of receiver (H), collector-orientation angle (52) and location. The expressions for the net energy collected by the working fluid, electricity generated by a collector and the cost of electricity are presented. The effects of L, w, p, n, H, Omega and location on energy losses, net energy collection by fluid, electricity generation and cost of electricity are studied. The minimum cost of electricity is found out for different collector-orientations at various locations and relative comparisons have been made. The corresponding collector parameters, annual energy collection by fluid and the annual electricity generation are also found out. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:114 / 138
页数:25
相关论文
共 50 条
  • [1] Effects of shading and blocking in compact linear fresnel reflector field
    Sharma, Vashi
    Khanna, Sourav
    Nayak, Jayanta K.
    Kedare, Shireesh B.
    ENERGY, 2016, 94 : 633 - 653
  • [2] Performance analysis of shading and blocking of linear Fresnel reflector mirror field
    Du, Chunxu
    Wang, Pu
    Wu, Yuting
    Ma, Chongfang
    Guo, Hang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2013, 34 (11): : 1868 - 1876
  • [3] Hourly and monthly variation in shading and blocking of aperture area in a linear fresnel reflector field
    Sharma, Vashi
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 233 - 241
  • [4] Calculation and Analysis Model of Shading and Blocking in Linear Fresnel Reflector System
    Liang Fei
    Zhang Na
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (12)
  • [5] Shading Efficiency Calculation For Linear Fresnel Reflector
    Elmaanaoui, Youssef
    Saifaoui, Dennoun
    2014 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2014, : 100 - 103
  • [6] Quantifying the Shading Effects of a Small-Scale Rooftop-Installed Linear Fresnel Reflector in Cyprus
    Montenon, Alaric Christian
    Papakokkinos, Giorgos
    Ilia, Kostantinos
    ENERGIES, 2024, 17 (13)
  • [7] Study on the Effect of Tilt on the Variation of Aperture Area Shading in a Linear Fresnel Reflector Field for Two Different Configurations
    Bhowmick, Gaurab
    Neogi, Subhasis
    ADVANCES IN SMART GRID AND RENEWABLE ENERGY, 2018, 435 : 147 - 156
  • [8] PERFORMANCE TESTING OF A LINEAR FRESNEL REFLECTOR
    SINGHAL, AK
    SHARMA, MS
    NEGI, BS
    MATHUR, SS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1986, 10 (01) : 39 - 46
  • [9] Concentration ratio analysis of linear Fresnel reflector
    Du C.
    Wang P.
    Wu Y.
    Ma C.
    Guangxue Xuebao/Acta Optica Sinica, 2011, 31 (08):
  • [10] Construction and Experimental Study of an Elevation Linear Fresnel Reflector
    Nixon, J. D.
    Davies, P. A.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (03):