Three-dimensional transesophageal echocardiographic morphological evaluation of the tricuspid valve

被引:3
|
作者
Kawase, Takumi [1 ]
Takahashi, Yosuke [1 ]
Ito, Asahiro [2 ]
Yoshida, Hisako [3 ]
Sumii, Yosuke [1 ]
Nishiya, Kenta [1 ]
Kishimoto, Noriaki [1 ]
Yamane, Kokoro [1 ]
Sakon, Yoshito [1 ]
Morisaki, Akimasa [1 ]
Fujii, Hiromichi [1 ]
Shibata, Toshihiko [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Cardiovasc Surg, Osaka, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
[3] Osaka City Univ, Grad Sch Med, Dept Med Stat, Osaka, Japan
关键词
Tricuspid valve; Two posterior leaflets; Three-dimensional transesophageal echocardiography; REAL-TIME; REGURGITATION;
D O I
10.1093/icvts/ivac145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The morphology of the tricuspid valve (TV), particularly valves with two posterior leaflets, is attracting attention. The present study was performed to investigate the usefulness of three-dimensional transoesophageal echocardiographic data for morphological evaluation of the TV . METHODS: Sixty patients underwent morphological evaluation of the TV by preoperative transoesophageal echocardiography followed by TV repair with median sternotomy, and each leaflet was measured intraoperatively. We analysed the TV morphology in 51 patients whose preoperative echocardiographic findings were consistent with intraoperative findings. RESULTS: The mid-systolic echo data, which included the annulus diameter of each leaflet, were correlated with the intraoperative evaluation findings compared with those in the mid-diastole. The annulus and area of the posterior leaflet were larger in patients with two than one posterior leaflet valve (42.4 +/- 13.5 vs 30.7 +/- 9.1 mm, P < 0.001 and 327 +/- 185 vs 208 +/- 77 mm(2), P = 0.006, respectively). In the severe tricuspid regurgitation patients, the annulus of the posterior leaflet was larger and the annulus of the anterior leaflet was smaller in patients with two than one posterior leaflet valve [posterior: 48 mm [95% confidence interval (CI), 41-54 mm] vs 36 mm (95% CI, 27-45 mm), respectively; P = 0.043 and anterior: 38 mm (95% CI, 33-42 mm) vs 46 mm (95% CI, 40-52 mm), respectively; P = 0.025]. CONCLUSIONS: Patients who had a TV with two posterior leaflets had a larger annulus and area of the posterior leaflets. Preoperative three-dimensional transoesophageal echocardiography is useful for the morphological evaluation of the TV.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Tricuspid Annular Geometry: A Three-Dimensional Transesophageal Echocardiographic Study
    Mahmood, Feroze
    Kim, Han
    Chaudary, Bilal
    Bergman, Remco
    Matyal, Robina
    Gerstle, Jeniffer
    Gorman, Joseph H., III
    Gorman, Robert C.
    Khabbaz, Kamal R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (04) : 639 - 646
  • [2] Three-dimensional echocardiography of the tricuspid valve
    Jost, Zachary T.
    Nooli, Nishank P.
    Ali, Ahmed E.
    Jaganathan, Vijayadithyan
    Nanda, Navin C.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [3] Real Time Three-Dimensional Transesophageal Echocardiographic Evaluation of Aortic Valve Perforation
    Bansal, Ramesh C.
    Chandrasekaran, Krishnaswamy
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (07): : 1147 - 1156
  • [4] Tricuspid valve geometry in patients with functional tricuspid regurgitation: A three-dimensional echocardiographic study
    Karamali, Fatemeh
    Hosseini, Saeid
    Shojaeifard, Maryam
    Mohammadi, Khadijeh
    Kaviani, Raheleh
    Rezaei, Yousef
    Samiei, Niloufar
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (06): : 867 - 875
  • [5] Three-dimensional transesophageal echocardiography incremental value in a rare case of a bileaflet tricuspid valve
    Mahmoud, Hani M.
    Walley, Hossam
    Hosny, Hatem
    Yacoub, Magdi
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (09): : 1438 - 1440
  • [6] Two-Dimensional Transesophageal Echocardiographic Imaging of the Tricuspid Valve
    Rehfeldt, Kent H.
    ANESTHESIA AND ANALGESIA, 2012, 114 (03) : 547 - 550
  • [7] Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography
    Yuasa T.
    Takasaki K.
    Mizukami N.
    Ueya N.
    Kubota K.
    Horizoe Y.
    Chaen H.
    Kuwahara E.
    Kisanuki A.
    Hamasaki S.
    Journal of Echocardiography, 2013, 11 (3) : 97 - 99
  • [8] Efficacy and Accuracy of Novel Automated Mitral Valve Quantification: Three-Dimensional Transesophageal Echocardiographic Study
    Kagiyama, Nobuyuki
    Toki, Misako
    Hara, Masahiko
    Fukuda, Shuichiro
    Aritaka, Shingo
    Miki, Tomonori
    Ohara, Minako
    Hayashida, Akihiro
    Hirohata, Atsushi
    Yamamoto, Keizo
    Yoshida, Kiyoshi
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (05): : 756 - 763
  • [9] Live/Real Time Three-Dimensional Transesophageal Echocardiographic Evaluation of Mitral and Aortic Valve Prosthetic Paravalvular Regurgitation
    Singh, Preeti
    Manda, Jayaprakash
    Hsiung, Ming Chon
    Mehta, Anjlee
    Kesanolla, Saritha Kumari
    Nanda, Navin C.
    Tsai, Shen-Kou
    Jeng-Wei
    Yin, Wei-Hsian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (08): : 980 - 987
  • [10] Comparison of Aortic Root Geometry with Bicuspid versus Tricuspid Aortic Valve: Real-Time Three-Dimensional Transesophageal Echocardiographic Study
    Shibayama, Kentaro
    Harada, Kenji
    Berdejo, Javier
    Tanaka, Jun
    Mihara, Hirotsugu
    Itabashi, Yuji
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (11) : 1143 - 1152