Electromembrane Extraction of Posaconazole for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Detection

被引:1
作者
Chen, Chi-Sheng [1 ]
Chen, Wen-Chi [2 ,3 ,4 ]
Chang, Sarah Y. [1 ]
机构
[1] Natl Kaohsiung Normal Univ, Dept Chem, 62 Shenjhong Rd, Kaohsiung 824, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Med, Div Gastroenterol & Hepatol, 386 Ta Chung 1st Rd, Kaohsiung 813, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Fac Med, Sch Med, Taipei 112, Taiwan
[4] Natl Sun Yat Sen Univ, Coll Sci, Inst Biomed Sci, Kaohsiung 804, Taiwan
关键词
electromembrane extraction; matrix-assisted laser desorption; ionization mass spectrometry; basic drug; posaconazole; LIQUID-LIQUID MICROEXTRACTION; POLYMER INCLUSION MEMBRANES; HUMAN PLASMA; ANTIFUNGAL DRUGS; TRIAZOLE; PERFORMANCE; SAMPLES;
D O I
10.3390/membranes12060620
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new mode of electromembrane extraction (EME) has been developed for detection via matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS). Posaconazole, extracted from 8 mL of a 10 mM trifluoroacetic acid solution onto a thin polyvinylidene difluoride (PVDF) membrane, was used as a model analyte. The transport was forced by an electrical potential difference between two electrodes inside the lumen of a hollow fiber and glass tube. Under an application of 80 V, cationic posaconazole in the sample solution moved toward the negative electrode inside the glass tube and was trapped by the PVDF membrane on the side. After 15 min of extraction, 3 mu L of alpha-cyano-4-hydroxycinnamic acid (CHCA) solution was applied on top of the membrane, which was then analyzed by MALDI/MS. Under optimal extraction conditions, the calibration curve of posaconazole was linear over a concentration range of 0.10-100.00 nM. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 0.03 nM with an enhancement factor of 138 for posaconazole. The application of this method to the determination of posaconazole in human serum samples was also successfully demonstrated.
引用
收藏
页数:11
相关论文
共 40 条
  • [1] Pharmacodynamics of a new triazole, posaconazole, in a murine model of disseminated candidiasis
    Andes, D
    Marchillo, K
    Conklin, R
    Krishna, G
    Ezzet, F
    Cacciapuoti, A
    Loebenberg, D
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2004, 48 (01) : 137 - 142
  • [2] Low-voltage electrochemically stimulated stir membrane liquid-liquid microextraction as a novel technique for the determination of methadone
    Ara, Katayoun Mahdavi
    Raofie, Farhad
    [J]. TALANTA, 2017, 168 : 105 - 112
  • [3] Electromembrane extraction of peptides
    Balchen, Marte
    Reubsaet, Leon
    Pedersen-Bjergaard, Stig
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (02) : 143 - 149
  • [4] Fast, selective, and sensitive analysis of low-abundance peptides in human plasma by electromembrane extraction
    Balchen, Marte
    Lund, Hanne
    Reubsaet, Leon
    Pedersen-Bjergaard, Stig
    [J]. ANALYTICA CHIMICA ACTA, 2012, 716 : 16 - 23
  • [5] Rapid isolation of angiotensin peptides from plasma by electromembrane extraction
    Balchen, Marte
    Halvorsen, Trine Gronhaug
    Reubsaet, Leon
    Pedersen-Bjergaard, Stig
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (41) : 6900 - 6905
  • [6] Combination of gel-electromembrane extraction with switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction followed by gas chromatography for the extraction and determination of antidepressants in human serum, breast milk and wastewater
    Behpour, Majid
    Nojavan, Saeed
    Asadi, Sakine
    Shokri, Ali
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2020, 1621 (1621)
  • [7] Rapid HPLC-MS/MS method for simultaneous quantitation of four routinely administered triazole antifungals in human plasma
    Beste, Kerstin Yvonne
    Burkhardt, Olaf
    Kaever, Volkhard
    [J]. CLINICA CHIMICA ACTA, 2012, 413 (1-2) : 240 - 245
  • [8] Effect of food on the relative bioavailability of two oral formulations of posaconazole in healthy adults
    Courtney, R
    Wexler, D
    Radwanski, E
    Lim, J
    Laughlin, M
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2004, 57 (02) : 218 - 222
  • [9] Use of Polymer Inclusion Membranes (PIMs) as support for electromembrane extraction of non-steroidal anti-inflammatory drugs and highly polar acidic drugs
    Cristina, Roman-Hidalgo
    Maria Jesus, Martin-Valero
    Rut, Fernandez-Torres
    Miguel Angel, Bello-Lopez
    [J]. TALANTA, 2018, 179 : 601 - 607
  • [10] Davarani SSH, 2015, ANAL METHODS-UK, V7, P2680, DOI [10.1039/c5ay00243e, 10.1039/C5AY00243E]