Development of a simple method for quantitation of methanesulfonic acid at low ppm level using hydrophilic interaction chromatography coupled with ESI-MS

被引:17
作者
Huang, Zongyun [1 ]
Francis, Robert [1 ]
Zha, Yan [1 ]
Ruan, Joan [1 ]
机构
[1] Bristol Myers Squibb, Analyt & Bioanalyt Dev, New Brunswick, NJ 08901 USA
关键词
Sulfonic acid; HILIC; Genotoxic impurity; Pharmaceutical; ESI-MS; ACTIVE PHARMACEUTICAL INGREDIENTS; POLAR STATIONARY PHASES; INTERACTION LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; MASS-SPECTROMETRY; SOLUTE RETENTION; SULFONIC-ACIDS; MOBILE PHASE; SEPARATION; ALKYL;
D O I
10.1016/j.jpba.2014.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and robust method using HILIC-ESI-MS has been developed for the determination of methane sulfonic acid (MSA) at low ppm level in order to verify the effectiveness of controlling the formation of genotoxic sulfonate esters in the downstream synthetic step, by which produces active pharmaceutical ingredient (API). Stationary phases with positively charged functional groups such as triazole and amino phases were evaluated for the retention of alkyl sulfonic acids. The MSA was quantitated at 1-10 ppm relative to the API using a Cosmosil column (triazole stationary phase) in HILIC mode and the control of MSA can be monitored effectively using the HILIC-ESI-MS methodology. In addition, to provide general guidance for the HILIC-ESI-MS method development, the retention behavior of propanesulfonic acid (PSA) in HILIC mode was investigated using a Unison UK-Amino column to have a better understanding of the HILIC separation mechanism. The results showed reasonable evidence that the combined effect of surface adsorption and ion-exchange played a dominant role for sulfonic acids when using a mobile phase within typical HILIC operation range (0.05-0.20 aqueous volume fraction) while the ion-exchange effect becomes increasingly important in a mobile phase with higher water content. The advantage of using ESI-MS detection in HILIC mode was also demonstrated by the observation that the sensitivity of PSA increased substantially with increasing acetonitrile fraction in mobile phase from 0.80 to 0.95. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 38 条
[31]   Development of a hydrophilic interaction liquid chromatography coupled with matrix-assisted laser desorption/ionization-mass spectrometric imaging platform for N-glycan relative quantitation using stable-isotope labeled hydrazide reagents [J].
Zhengwei Chen ;
Xuefei Zhong ;
Cai Tie ;
Bingming Chen ;
Xinxiang Zhang ;
Lingjun Li .
Analytical and Bioanalytical Chemistry, 2017, 409 :4437-4447
[32]   Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography-Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method [J].
Ruiz, Wladimir ;
Fontagne-Dicharry, Stephanie ;
Verdier, Sylvain ;
Dayton, David C. ;
Guillemant, Julie ;
Moulian, Remi ;
Giusti, Pierre ;
Barrere-Mangote, Caroline ;
Bouyssiere, Brice .
ANALYTICAL CHEMISTRY, 2024, 96 (38) :15142-15150
[33]   Development and validation of a method using ultra performance liquid chromatography coupled to tandem mass spectrometry for determination of zoledronic acid concentration in human bone [J].
Lo Faro, Alfredo Fabrizio ;
Giorgetti, Raffaele ;
Busardo, Francesco Paolo ;
Lodi, Giovanni ;
Martini, Valeria ;
Pispero, Alberto ;
Iriti, Marcello ;
Varoni, Elena Maria .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 :286-290
[34]   Hydrophilic interaction chromatography-multiple reaction monitoring mass spectrometry method for basic building block analysis of low molecular weight heparins prepared through nitrous acid depolymerization [J].
Sun, Xiaojun ;
Guo, Zhimou ;
Yu, Mengqi ;
Lin, Chao ;
Sheng, Anran ;
Wang, Zhiyu ;
Linhardt, Robert J. ;
Chi, Lianli .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1479 :121-128
[35]   Development of a simple and valid method for the trace determination of phthalate esters in human plasma using dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry [J].
Ebrahim, Karim ;
Poursafa, Parinaz ;
Amin, Mohammad Mehdi .
JOURNAL OF SEPARATION SCIENCE, 2017, 40 (22) :4403-4410
[36]   Simultaneous determination of the quaternary ammonium pesticides paraquat, diquat, chlormequat, and mepiquat in barley and wheat using a modified quick polar pesticides method, diluted standard addition calibration and hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry [J].
Francesquett, Janice Z. ;
Rizzetti, Tiele M. ;
Cadaval, Tito R. S., Jr. ;
Prestes, Osmar D. ;
Adaime, Martha B. ;
Zanella, Renato .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1592 :101-111
[38]   A high-throughput hydrophilic interaction liquid chromatography coupled with a charged aerosol detector method to assess trisulfides in IgG1 monoclonal antibodies using tris(2-carboxyethyl)phosphine reaction products: Tris(2-carboxyethyl)phosphine-oxide and tris(2-carboxyethyl)phosphine-sulfide [J].
Cornell, Christopher ;
Karanjit, Amish ;
Chen, Yan ;
Jacobson, Fredric .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1457 :107-115