Development of a simple method for quantitation of methanesulfonic acid at low ppm level using hydrophilic interaction chromatography coupled with ESI-MS

被引:17
作者
Huang, Zongyun [1 ]
Francis, Robert [1 ]
Zha, Yan [1 ]
Ruan, Joan [1 ]
机构
[1] Bristol Myers Squibb, Analyt & Bioanalyt Dev, New Brunswick, NJ 08901 USA
关键词
Sulfonic acid; HILIC; Genotoxic impurity; Pharmaceutical; ESI-MS; ACTIVE PHARMACEUTICAL INGREDIENTS; POLAR STATIONARY PHASES; INTERACTION LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; MASS-SPECTROMETRY; SOLUTE RETENTION; SULFONIC-ACIDS; MOBILE PHASE; SEPARATION; ALKYL;
D O I
10.1016/j.jpba.2014.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and robust method using HILIC-ESI-MS has been developed for the determination of methane sulfonic acid (MSA) at low ppm level in order to verify the effectiveness of controlling the formation of genotoxic sulfonate esters in the downstream synthetic step, by which produces active pharmaceutical ingredient (API). Stationary phases with positively charged functional groups such as triazole and amino phases were evaluated for the retention of alkyl sulfonic acids. The MSA was quantitated at 1-10 ppm relative to the API using a Cosmosil column (triazole stationary phase) in HILIC mode and the control of MSA can be monitored effectively using the HILIC-ESI-MS methodology. In addition, to provide general guidance for the HILIC-ESI-MS method development, the retention behavior of propanesulfonic acid (PSA) in HILIC mode was investigated using a Unison UK-Amino column to have a better understanding of the HILIC separation mechanism. The results showed reasonable evidence that the combined effect of surface adsorption and ion-exchange played a dominant role for sulfonic acids when using a mobile phase within typical HILIC operation range (0.05-0.20 aqueous volume fraction) while the ion-exchange effect becomes increasingly important in a mobile phase with higher water content. The advantage of using ESI-MS detection in HILIC mode was also demonstrated by the observation that the sensitivity of PSA increased substantially with increasing acetonitrile fraction in mobile phase from 0.80 to 0.95. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 29 条
[21]   Water uptake on polar stationary phases under conditions for hydrophilic interaction chromatography and its relation to solute retention [J].
Ngoc Phuoc Dinh ;
Jonsson, Tobias ;
Irgum, Knut .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1320 :33-47
[22]   The advantages of ESI-MS detection in conjunction with HILIC mode separations: Fundamentals and applications [J].
Nguyen, Hien P. ;
Schug, Kevin A. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (09) :1465-1480
[23]   Thermodynamic studies of a zwitterionic stationary phase in hydrophilic interaction liquid chromatography [J].
Qiu, Haixiao ;
Armstrong, Daniel W. ;
Berthod, Alain .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1272 :81-89
[24]   Ion exchange chromatographic determination of olpadronate, phosphate, phosphite, chloride and methanesulfonic acid [J].
Quattrocchi, O ;
Frisardi, L ;
Iglesias, M ;
Noya, M ;
Caputto, M ;
Ferraris, D ;
Siliprandi, D ;
Piccinni, E .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :1011-1018
[25]   Residues of genotoxic alkyl mesylates in mesylate salt drug substances: Real or imaginary problems? [J].
Snodin, DJ .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2006, 45 (01) :79-90
[26]   MECHANISM OF SOLUTE RETENTION IN LIQUID-SOLID CHROMATOGRAPHY AND THE ROLE OF THE MOBILE PHASE IN AFFECTING SEPARATION - COMPETITION VERSUS SORPTION [J].
SNYDER, LR ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1980, 184 (04) :363-413
[27]   Retention models for ions in chromatography [J].
Ståhlberg, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :3-55
[28]   Mechanism of retention loss when C8 and C18HPLC columns are used with highly aqueous mobile phases [J].
Walter, TH ;
Iraneta, P ;
Capparella, M .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :177-183
[29]   Separation properties of novel and commercial polar stationary phases in hydrophilic interaction and reversed-phase liquid chromatography mode [J].
Wu, JunYan ;
Bicker, Wolfgang ;
Lindner, Wolfgang .