Development of a simple method for quantitation of methanesulfonic acid at low ppm level using hydrophilic interaction chromatography coupled with ESI-MS

被引:17
作者
Huang, Zongyun [1 ]
Francis, Robert [1 ]
Zha, Yan [1 ]
Ruan, Joan [1 ]
机构
[1] Bristol Myers Squibb, Analyt & Bioanalyt Dev, New Brunswick, NJ 08901 USA
关键词
Sulfonic acid; HILIC; Genotoxic impurity; Pharmaceutical; ESI-MS; ACTIVE PHARMACEUTICAL INGREDIENTS; POLAR STATIONARY PHASES; INTERACTION LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; MASS-SPECTROMETRY; SOLUTE RETENTION; SULFONIC-ACIDS; MOBILE PHASE; SEPARATION; ALKYL;
D O I
10.1016/j.jpba.2014.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and robust method using HILIC-ESI-MS has been developed for the determination of methane sulfonic acid (MSA) at low ppm level in order to verify the effectiveness of controlling the formation of genotoxic sulfonate esters in the downstream synthetic step, by which produces active pharmaceutical ingredient (API). Stationary phases with positively charged functional groups such as triazole and amino phases were evaluated for the retention of alkyl sulfonic acids. The MSA was quantitated at 1-10 ppm relative to the API using a Cosmosil column (triazole stationary phase) in HILIC mode and the control of MSA can be monitored effectively using the HILIC-ESI-MS methodology. In addition, to provide general guidance for the HILIC-ESI-MS method development, the retention behavior of propanesulfonic acid (PSA) in HILIC mode was investigated using a Unison UK-Amino column to have a better understanding of the HILIC separation mechanism. The results showed reasonable evidence that the combined effect of surface adsorption and ion-exchange played a dominant role for sulfonic acids when using a mobile phase within typical HILIC operation range (0.05-0.20 aqueous volume fraction) while the ion-exchange effect becomes increasingly important in a mobile phase with higher water content. The advantage of using ESI-MS detection in HILIC mode was also demonstrated by the observation that the sensitivity of PSA increased substantially with increasing acetonitrile fraction in mobile phase from 0.80 to 0.95. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 38 条
  • [1] Separation of multiphosphorylated cyclopeptides and their positional isomers by hydrophilic interaction liquid chromatography (HILIC) coupled to electrospray ionization mass spectrometry (ESI-MS)
    Zeid, Lana Abou
    Pell, Albert
    Tytus, Theo
    Delangle, Pascale
    Bresson, Carole
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1177
  • [2] Glycosphingolipidomics of donkey milk by hydrophilic interaction liquid chromatography coupled to ESI and multistage MS
    Calvano, Cosima Damiana
    Glaciale, Marco
    Palmisano, Francesco
    Cataldi, Tommaso R. I.
    ELECTROPHORESIS, 2018, 39 (13) : 1634 - 1644
  • [3] Separation of Organoarsenicals by Means of Zwitterionic Hydrophilic Interaction Chromatography (ZIC®-HILIC) and Parallel ICP-MS/ESI-MS Detection
    Xie, D.
    Mattusch, J.
    Wennrich, R.
    ENGINEERING IN LIFE SCIENCES, 2008, 8 (06): : 582 - 588
  • [4] Comparison of peak shape in hydrophilic interaction chromatography using acidic salt buffers and simple acid solutions
    Heaton, James C.
    Russell, Joseph J.
    Underwood, Tim
    Boughtflower, Robert
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1347 : 39 - 48
  • [5] Development of a precise quantitative method for monitoring sirolimus in whole blood using LC/ESI-MS/MS
    Shigeta, Kensuke
    Kikuchi, Masafumi
    Tanaka, Masaki
    Takasaki, Shinya
    Oishi, Hisashi
    Sado, Tetsu
    Matsuda, Yasushi
    Noda, Masafumi
    Okada, Yoshinori
    Mano, Nariyasu
    Yamaguchi, Hiroaki
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (08)
  • [6] Development of rapid and simultaneous quantitative method for green tea catechins on the bioanalytical study using UPLC/ESI-MS
    Misaka, Shingen
    Kawabe, Keisuke
    Onoue, Satomi
    Werba, Jose Pablo
    Giroli, Monica
    Kimura, Junko
    Watanabe, Hiroshi
    Yamada, Shizuo
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 1 - 6
  • [7] Development of a LC-MS method for simultaneous determination of amoxicillin and metronidazole in human serum using hydrophilic interaction chromatography (HILIC)
    Kathriarachchi, Udani L.
    Vidhate, Sagar S.
    Al-Tannak, Naser
    Thomson, Alison H.
    da Silva Neto, Michael J. J.
    Watson, David G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1089 : 78 - 83
  • [8] Development and evaluation of a hydrophilic interaction liquid chromatography-MS/MS method to quantify 19 nucleobases and nucleosides in rat plasma
    Du, Yan
    Li, Yin-jie
    Hu, Xun-xiu
    Deng, Xu
    Qian, Zeng-ting
    Li, Zheng
    Guo, Meng-zhe
    Tang, Dao-quan
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (04)
  • [9] Validated LC coupled to ESI-MS/MS analysis for fentanyl in human plasma and UV analysis in applied reservoir transdermal patches using a simple and rapid procedure
    Takashina, Y.
    Naito, T.
    Mino, Y.
    Kagawa, Y.
    Kawakami, J.
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2009, 34 (05) : 523 - 529
  • [10] Accurate and efficient amino acid analysis for protein quantification using hydrophilic interaction chromatography coupled tandem mass spectrometry
    Kambhampati, Shrikaar
    Li, Jia
    Evans, Bradley S.
    Allen, Doug K.