A new approach to design an observer for load current of UPS based on Fourier series theory in model predictive control system

被引:17
作者
Heydari-Doostabad, Hamed [1 ]
Ghazi, Reza [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Elect Engn, Fac Engn, Mashhad, Iran
关键词
Model predictive control (MPC); Uninterruptable power supply (UPS); Load current observer (LCO); 3-Phase inverter; LC filter; Luenberger observer; DIRECT POWER-CONTROL; CONTROL STRATEGY; VOLTAGE; INVERTERS; FILTER; LC; STABILITY; SELECTION; FUZZY;
D O I
10.1016/j.ijepes.2018.07.047
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the model predictive control (MPC) system based on the state space is designed to generate the appropriate switching pulses for UPS inverters. The fast dynamic response and the capability in assessment of various cost functions are some advantages of the predictive control system. The equations concerning the control system show that the load current should be measured. To eliminate the required sensor for load current measurement a new observer is proposed, so the amount of cost can be reduced and the reliability of the system also enhanced. Ordinary observers like Luenberger in terms of stability and design encounter several difficulties. The proposed observer is developed based on Fourier series and instantaneous power theories. This observer is doing well in estimating the load current and renders superior performance regarding the dynamic behavior, stability and convergence. Furthermore, in this observer there is no need for any parameters adjustment and the load current is accurately observed using the measured output voltage and the filter current. To examine the operation of the system the necessary simulations and laboratory experimental results are provided on a 3-phase 220 V UPS. The obtained results are then compared to those obtained by the Luenberger observer.
引用
收藏
页码:898 / 909
页数:12
相关论文
共 40 条
[1]  
[Anonymous], IEEE T IND ELECT
[2]   Reduced-Complexity Iterative Receiver for Improving the IEEE 802.15.7 Convolutional-Coded Color Shift Keying Mode [J].
Babar, Zunaira ;
Zhu, Chuan ;
Hung Viet Nguyen ;
Botsinis, Panagiotis ;
Alanis, Dimitrios ;
Chandra, Daryus ;
Ng, Soon Xin ;
Hanzo, Lajos .
IEEE COMMUNICATIONS LETTERS, 2017, 21 (09) :2005-2008
[3]   Improved SVPWM vector selection approaches in OVM region to reduce common-mode voltage for three-level neutral point clamped-inverter [J].
Bharatiraja, C. ;
Jeevananthan, S. ;
Munda, J. L. ;
Latha, R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 79 :285-297
[4]   Fuzzy-Logic-Based Switching State Selection for Direct Power Control of Three-Phase PWM Rectifier [J].
Bouafia, Abdelouahab ;
Krim, Fateh ;
Gaubert, Jean-Paul .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :1984-1992
[5]   Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation [J].
Bouafia, Abdelouahab ;
Krim, Fateh ;
Gaubert, Jean-Paul .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (01) :6-13
[6]   Analysis and Design of New Switching Table for Direct Power Control of Three-Phase PWM Rectifier [J].
Bouafia, Abdelouahab ;
Gaubert, Jean-Paul ;
Krim, Fateh .
2008 13TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-5, 2008, :703-+
[7]   A New Generalized Robust Predictive Current Control for Grid-Connected Inverters Compensates Anti-Aliasing Filters Delay [J].
Castello, Jaime ;
Espi, Jose M. ;
Garcia-Gil, Rafael .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (07) :4485-4494
[8]   Virtual-Flux-Based Predictive Direct Power Control of Three-Phase PWM Rectifiers With Fast Dynamic Response [J].
Cho, Yongsoo ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) :3348-3359
[9]   Model Predictive Control of an Inverter With Output LC Filter for UPS Applications [J].
Cortes, Patricio ;
Ortiz, Gabriel ;
Yuz, Juan I. ;
Rodriguez, Jose ;
Vazquez, Sergio ;
Franquelo, Leopoldo G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :1875-1883
[10]   A line-interactive UPS system implementation with series-parallel active power-line conditioning for three-phase, four-wire systems [J].
da Silva, SAO ;
Donoso-Garcia, P ;
Cortizo, PC ;
Seixas, PF .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2004, 26 (06) :399-411