Interrogation of the aortic valve

被引:1
作者
Friedrich, Andrew D. [1 ]
Shekar, Prem S.
机构
[1] Univ Cincinnati, Coll Med, Dept Anesthesiol, Cincinnati, OH 45221 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Div Cardiac Surg, Boston, MA 02115 USA
关键词
aortic valve; aortic stenosis; aortic regurgitation; effective regurgitant orifice area; transesophageal echocardiography; two-dimensional examination; pulse-wave Doppler; continuous-wave Doppler; color Doppler; Bernoulli equation; continuity equation; cardiac surgery; aortic valve replacement; aortic valve repair; myocardial protection;
D O I
10.1097/01.CCM.0000271160.50021.21
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To review the essential elements of the transesophageal echocardiographic examination of the aortic valve, with emphasis on the technique for performing a two-dimensional examination, the quantification of aortic stenosis and regurgitation, and the effect of this modality on cardiac surgical decision making. Design: Literature review. Discussion. Transesophageal echocardiographic examination of the aortic valve can provide detailed information on aortic valve structure and function, provided proper technique is utilized. This review presents the current recommendations from the American Society of Echocardiography for the performance of a two-dimensional examination of the aortic valve and for the quantification of aortic stenosis or aortic regurgitation by application of Doppler techniques. To demonstrate the applicability of transesophageal echocardiography in clinical practice, the effect of transesophageal echocardiography on the cardiac surgical management of patients with aortic valvular disease is described.
引用
收藏
页码:S365 / S371
页数:7
相关论文
共 24 条
  • [1] Annular abscesses in surgical endocarditis: Anatomic, clinical, and operative features
    Baumgartner, FJ
    Omari, BO
    Robertson, JM
    Nelson, RJ
    Pandya, A
    Pandya, A
    Milliken, JC
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (02) : 442 - 447
  • [2] Overestimation of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery
    Baumgartner, H
    Stefenelli, T
    Niederberger, J
    Schima, H
    Maurer, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) : 1655 - 1661
  • [3] BONOW RO, ACC AHA 2006 GUIDELI
  • [4] Change in mitral regurgitation severity after aortic valve replacement for aortic stenosis
    Brasch, AV
    Khan, SS
    DeRobertis, MA
    Kong, JHK
    Chiu, J
    Siegel, RJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (10) : 1271 - +
  • [5] Christenson JT, 2000, TEX HEART I J, V27, P350
  • [6] Diagnostic accuracy of transthoracic and multiplane transesophageal echocardiography for valvular perforation in acute infective endocarditis: Correlation with anatomic findings
    De Castro, S
    Cartoni, D
    d'Amati, G
    Beni, S
    Yao, JF
    Fiorelli, M
    Gallo, P
    Fedele, F
    Pandian, NG
    [J]. CLINICAL INFECTIOUS DISEASES, 2000, 30 (05) : 825 - 826
  • [7] FOX JA, 2003, CARDIAC SURG ADULT
  • [8] Grimm Richard A., 1998, Cardiology Clinics, V16, P477, DOI 10.1016/S0733-8651(05)70027-8
  • [9] Improvement in mitral regurgitation after aortic valve replacement
    Harris, KM
    Malenka, DJ
    Haney, MF
    Jayne, JE
    Hettleman, B
    Plehn, JF
    Griffin, BP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (06) : 741 - 745
  • [10] Nitroprusside in critically ill patients with left ventricular dysfunction and aortic stenosis
    Khot, UN
    Novaro, GM
    Popovic, ZB
    Mills, RM
    Thomas, JD
    Tuzcu, EM
    Hammer, D
    Nissen, SE
    Francis, GS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (18) : 1756 - 1763