Effects of different fresh gas flows and different anesthetics on airway temperature and humidity in surgical patients: a prospective observational study

被引:4
作者
Ozcan, Irem [1 ]
Onal, Ozkan [1 ,2 ]
Ozdemirkan, Aysun [1 ]
Saltali, Ali [1 ]
Sari, Mehmet [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Anesthesiol & Intens Care, Konya, Turkey
[2] Cleveland Clin, Main Hosp, Dept Outcomes Res, Anesthesiol Inst, Cleveland, OH 44106 USA
关键词
airway; breathing systems; equipment; fresh gas; general anesthesia; heated humidifier; humidity; temperature; MOISTURE EXCHANGER; HEAT; HUMIDIFICATION; DESFLURANE;
D O I
10.4103/2045-9912.330691
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
This study was aimed to investigate the effects of different fresh gas (oxygen + air) flow rates and different anesthetics on airway temperature and humidity when using the same anesthesia machine in patients undergoing general anesthesia. In this prospective, observational study, 240 patients with American Society of Anesthesiologists (ASA) I-II between the age of 18-65 years to be operated under general anesthesia were enrolled and divided into two groups according to the fresh gas flow rate (3-6 L/min). Each of the two main groups was further divided into three subgroups according to the administered anesthetic gases and drugs. The resulting six groups were further divided into two subgroups according to whether the heat and humidity exchanger filter (HME) was attached to the breathing circuit, and the study was carried out on a total of 12 groups. The temperature and humidity of the inspired air were recorded every 10 minutes using an electronic thermo-hygrometer. The inspired temperature and humidity were greater in patients ventilated at 3 L/min compared to the 6 L/min group and in HME (+) patients compared to HME (-), regardless of the type of anesthetics. HME application makes the air more physiological for the respiratory tract by increasing the temperature and humidity of the air regardless of the anesthetic agent. This study was approved by Ethics Committee Review of Selcuk University Faculty of Medicine (No. 2017/261) in September 2017, and was registered in the Clinical Trial Registry (identifier No. NCT04204746) on December 19, 2019.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 26 条
[1]  
BAUM J, 1987, ANAESTHESIST, V36, P393
[2]   Low-flow anesthesia: Theory, practice, technical preconditions, advantages, and foreign gas accumulation [J].
Baum J.A. .
Journal of Anesthesia, 1999, 13 (3) :166-174
[3]  
Baum JA., 2002, DUSUK AKIMLI ANESTEZ
[4]  
BERGMANN H, 1986, ANAESTHESIST, V35, P587
[5]   Comparison of the effects of low-flow and high-flow inhalational anaesthesia with nitrous oxide and desflurane on mucociliary activity and pulmonary function tests [J].
Bilgi, Murat ;
Goksu, Sitki ;
Mizrak, Ayse ;
Cevik, Cengiz ;
Gul, Rauf ;
Koruk, Senem ;
Sahin, Levent .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (04) :279-283
[6]   Tracheobronchial consequences of the use of heat and moisture exchangers in dogs [J].
Bisinotto, FMB ;
Braz, JRC ;
Martins, RHG ;
Gregório, EA ;
Abud, TMV .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (09) :897-903
[7]   Anaesthesia circuits, humidity output, and mucociliary structure and function [J].
Branson, RD ;
Campbell, RS ;
Davis, K ;
Porembka, DT .
ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (02) :178-183
[8]   EFFECTS OF DRY ANESTHETIC GASES ON TRACHEOBRONCHIAL CILIATED EPITHELIUM [J].
CHALON, J ;
MALEBRANCHE, J ;
LOEW, DAY .
ANESTHESIOLOGY, 1972, 37 (03) :338-+
[9]   Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations Updated guidelines for reporting parallel group randomized trials [J].
Choi, Yoon Ji ;
Min, Sam Hong ;
Park, Jeong Jun ;
Cho, Jang Eun ;
Yoon, Seung Zhoo ;
Yoon, Suk Min .
MEDICINE, 2017, 96 (25)
[10]   The Temperature and Humidity in a Low-Flow Anesthesia Workstation With and Without a Heat and Moisture Exchanger [J].
de Castro, Jair, Jr. ;
Bolfi, Fernanda ;
de Carvalho, Lidia R. ;
Braz, Jose R. C. .
ANESTHESIA AND ANALGESIA, 2011, 113 (03) :534-538