Effects of different fresh gas flows and different anesthetics on airway temperature and humidity in surgical patients: a prospective observational study

被引:4
|
作者
Ozcan, Irem [1 ]
Onal, Ozkan [1 ,2 ]
Ozdemirkan, Aysun [1 ]
Saltali, Ali [1 ]
Sari, Mehmet [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Anesthesiol & Intens Care, Konya, Turkey
[2] Cleveland Clin, Main Hosp, Dept Outcomes Res, Anesthesiol Inst, Cleveland, OH 44106 USA
来源
MEDICAL GAS RESEARCH | 2022年 / 12卷 / 03期
关键词
airway; breathing systems; equipment; fresh gas; general anesthesia; heated humidifier; humidity; temperature; MOISTURE EXCHANGER; HEAT; HUMIDIFICATION; DESFLURANE;
D O I
10.4103/2045-9912.330691
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
This study was aimed to investigate the effects of different fresh gas (oxygen + air) flow rates and different anesthetics on airway temperature and humidity when using the same anesthesia machine in patients undergoing general anesthesia. In this prospective, observational study, 240 patients with American Society of Anesthesiologists (ASA) I-II between the age of 18-65 years to be operated under general anesthesia were enrolled and divided into two groups according to the fresh gas flow rate (3-6 L/min). Each of the two main groups was further divided into three subgroups according to the administered anesthetic gases and drugs. The resulting six groups were further divided into two subgroups according to whether the heat and humidity exchanger filter (HME) was attached to the breathing circuit, and the study was carried out on a total of 12 groups. The temperature and humidity of the inspired air were recorded every 10 minutes using an electronic thermo-hygrometer. The inspired temperature and humidity were greater in patients ventilated at 3 L/min compared to the 6 L/min group and in HME (+) patients compared to HME (-), regardless of the type of anesthetics. HME application makes the air more physiological for the respiratory tract by increasing the temperature and humidity of the air regardless of the anesthetic agent. This study was approved by Ethics Committee Review of Selcuk University Faculty of Medicine (No. 2017/261) in September 2017, and was registered in the Clinical Trial Registry (identifier No. NCT04204746) on December 19, 2019.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 9 条
  • [1] Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials
    Braz, Jose R. C.
    Braz, Mariana G.
    Hayashi, Yoko
    Martins, Regina H. G.
    Betini, Marluci
    Braz, Leandro G.
    El Dib, Regina
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (08) : 515 - 525
  • [2] The Effect of Anaesthesia Management with Different Fresh Gas Flows on Cognitive Functions of Geriatric Patients: A Randomized Double-blind Study
    Kilic, Bilge Ozge
    Karadeniz, Meltem Savran
    Senturk, Emre
    Guler, Meltem Merve
    Gurvit, Ibrahim Hakan
    Sungur, Zerrin
    Demirel, Ebru
    Tugrul, Kamil Mehmet
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2023, 51 (03) : 219 - 226
  • [3] Effects of ambient temperature and humidity on viruses activity on different architectural coatings and kinetics study
    Zhu, Changcai
    Li, Yulian
    Liu, Ruirui
    Ji, Zhijiang
    Zhao, Chunyan
    Wang, Jing
    Xie, Shuai
    Guo, Chunhong
    PROGRESS IN ORGANIC COATINGS, 2023, 183
  • [4] Effects of different fresh gas flows on carboxyhemoglobin levels: non-invasive carbon monoxide monitoring A randomized clinical trial
    Koksal, Bengu G.
    Kucukosman, Gamze
    Ozcan, Piskin
    Baytar, Cagdas
    Bollucuoglu, Keziban
    Okyay, Rahsan D.
    Ayoglu, Hilal
    SAUDI MEDICAL JOURNAL, 2022, 43 (08) : 891 - 898
  • [5] The effects of CO2 pneumoperitoneum at different temperature and humidity on hemodynamic and respiratory parameters and postoperative pain in gynecological laparoscopic surgery: A prospective randomized controlled study
    Gunusen, Ilkben
    Akdemir, Ali
    Sargin, Asuman
    Karaman, Semra
    ASIAN JOURNAL OF SURGERY, 2022, 45 (01) : 154 - 161
  • [6] Effects of temperature and relative humidity on the COVID-19 pandemic in different climates: a study across some regions in Algeria (North Africa)
    Boufekane, Abdelmadjid
    Busico, Gianluigi
    Maizi, Djamel
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (12) : 18077 - 18102
  • [7] Effects of temperature and relative humidity on the COVID-19 pandemic in different climates: a study across some regions in Algeria (North Africa)
    Abdelmadjid Boufekane
    Gianluigi Busico
    Djamel Maizi
    Environmental Science and Pollution Research, 2022, 29 : 18077 - 18102
  • [8] Effects of different fluid-administration regimens without urinary catheterization in patients undergoing general anesthesia: A prospective randomized controlled study
    Zhao, Xiaoning
    Li, Xiaoqian
    Tan, Wenfei
    Sun, Xijia
    ASIAN JOURNAL OF SURGERY, 2023, 46 (04) : 1844 - 1845
  • [9] Evaluation of tissue oxygenation and block quality using Near Infrared Spectroscopy (NIRS) in patients undergoing ultrasound-guided infraclavicular block at different arm angles A prospective observational study
    Binici, Orhan
    Karahan, Mahmut Alp
    Buyukfirat, Evren