Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures

被引:15
作者
Seo, Joongbae [1 ]
Heo, Kang [1 ]
Kim, Seong-Jun [1 ]
Kim, Jun-Kyom [1 ]
Ham, Hee-Jung [1 ]
Yoo, Jaesung [1 ]
机构
[1] Dankook Univ, Dept Orthopaed Surg, Coll Med, Cheonan, South Korea
关键词
Distal clavicle fracture; Neer type V; Coracoclavicular distance; Clavicular hook plate; STABILIZATION;
D O I
10.1016/j.otsr.2019.10.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The conventional AO hook locking compression plate (LCP) (Synthes, Solothurn, Switzerland) has only three holes for lateral fragments; therefore it is not suitable for use during the fixation of small-comminuted fragments in some cases. Recently, a novel hybrid hook LCP (TDM, Seoul, Korea) was developed to overcome this limitation. Here, we evaluated the clinical and radiologic outcomes of a novel hybrid hook LCP for Neer type V distal clavicle fractures compared to the outcomes of a conventional AO hook plate. Methods: Seventy-eight consecutive patients who underwent hook LCP fixation for Neer type V distal clavicle fractures were included. The subjects were divided into 2 groups: the conventional AO hook LCP group and the novel hybrid hook LCP group. For clinical assessments, the American Shoulder and Elbow Surgeons (ASES) score, Korean shoulder score (KSS), and Constant score were recorded. The percentage modified coracoclavicular distance (MCCD %) was used for the evaluation of fracture reduction. Typical reported complications, such as secondary dislocation, implant failure or loosening, peri-implant fracture, acromion osteolysis, postoperative acromioclavicular joint arthrosis, non-union, or delayed union, were also analyzed. Results: There were no differences in the clinical outcomes (ASES, KSS, and Constant scores) between the two groups. Bone union was achieved in a significantly shorter period in the hybrid hook LCP group (13.6 +/- 2.0 weeks) than in the AO hook LCP group (17.5 +/- 4.8 weeks, p < 0.001). Consequently, the time to implant removal was also significantly shorter in the hybrid hook LCP group (4.0 +/- 0.5 months) than in the AO hook LCP group (5.4 +/- 1.1 months, p < 0.001). The MCCD% showed no significant differences between the treatment groups. There was no statistically significant difference in the complication rate between the two groups; however, the hybrid hook LCP fixation resulted in a lower prevalence of hook-related complications. Conclusion: The hybrid hook LCP fixation showed satisfactory clinical and radiologic outcomes in comparison with the AO hook LCP fixation. The hybrid hook LCP is useful for multiple screw fixation of inferior comminuted fragments in Neer type V distal clavicle fractures. The bone union was significantly shorter; thus, the time to implant removal was also significantly shorter. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 25 条
  • [11] Dynamic stabilization using the Dynesys system versus posterior lumbar interbody fusion for the treatment of degenerative lumbar spinal disease: a clinical and radiological outcomes-based meta-analysis
    Lee, Chang-Hyun
    Jahng, Tae-Ahn
    Hyun, Seung-Jae
    Kim, Chi Heon
    Park, Sung-Bae
    Kim, Ki-Jeong
    Chung, Chun Kee
    Kim, Hyun-Jib
    Lee, Soo-Eon
    [J]. NEUROSURGICAL FOCUS, 2016, 40 (01)
  • [12] Precontoured Locking Plate Fixation for Displaced Lateral Clavicle Fractures
    Lee, Sang Ki
    Lee, Jae Won
    Song, Dae Geon
    Choy, Won Sik
    [J]. ORTHOPEDICS, 2013, 36 (06) : 801 - 807
  • [13] Clavicle hook plate fixation for distal-third clavicle fracture (Neer type II): comparison of clinical and radiologic outcomes between Neer types IIA and IIB
    Lee, Wonyong
    Choi, Chong-Hyuk
    Choi, Yun-Rak
    Lim, Kyung-Han
    Chun, Yong-Min
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (07) : 1210 - 1215
  • [14] Outcome of arthroscopic treatment for displaced lateral clavicle fractures using a double button device
    Loriaut, Philippe
    Moreau, Pierre-Emmanuel
    Dallaudiere, Benjamin
    Pelissier, Alexandre
    Hoang Duc Vu
    Massin, Philippe
    Boyer, Patrick
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (05) : 1429 - 1433
  • [15] NEER CS, 1968, CLIN ORTHOP RELAT R, P43
  • [16] Treatment of distal clavicle fracture: a systematic review of treatment modalities in 425 fractures
    Oh, Joo Han
    Kim, Sae Hoon
    Lee, Jung Ha
    Shin, Seung Han
    Gong, Hyun Sik
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (04) : 525 - 533
  • [17] Press Jeffrey, 1997, Bulletin Hospital for Joint Diseases, V56, P77
  • [18] The Clavicle Hook Plate for Neer Type II Lateral Clavicle Fractures
    Renger, R. J.
    Roukema, G. R.
    Reurings, J. C.
    Raams, P. M.
    Font, J.
    Verleisdonk, E. J. M. M.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 570 - 574
  • [19] Fractures of the clavicle in the adult - Epidemiology and classification
    Robinson, CM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03): : 476 - 484
  • [20] Rokito Andrew S, 2002, Bull Hosp Jt Dis, V61, P32