Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures

被引:15
作者
Seo, Joongbae [1 ]
Heo, Kang [1 ]
Kim, Seong-Jun [1 ]
Kim, Jun-Kyom [1 ]
Ham, Hee-Jung [1 ]
Yoo, Jaesung [1 ]
机构
[1] Dankook Univ, Dept Orthopaed Surg, Coll Med, Cheonan, South Korea
关键词
Distal clavicle fracture; Neer type V; Coracoclavicular distance; Clavicular hook plate; STABILIZATION;
D O I
10.1016/j.otsr.2019.10.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The conventional AO hook locking compression plate (LCP) (Synthes, Solothurn, Switzerland) has only three holes for lateral fragments; therefore it is not suitable for use during the fixation of small-comminuted fragments in some cases. Recently, a novel hybrid hook LCP (TDM, Seoul, Korea) was developed to overcome this limitation. Here, we evaluated the clinical and radiologic outcomes of a novel hybrid hook LCP for Neer type V distal clavicle fractures compared to the outcomes of a conventional AO hook plate. Methods: Seventy-eight consecutive patients who underwent hook LCP fixation for Neer type V distal clavicle fractures were included. The subjects were divided into 2 groups: the conventional AO hook LCP group and the novel hybrid hook LCP group. For clinical assessments, the American Shoulder and Elbow Surgeons (ASES) score, Korean shoulder score (KSS), and Constant score were recorded. The percentage modified coracoclavicular distance (MCCD %) was used for the evaluation of fracture reduction. Typical reported complications, such as secondary dislocation, implant failure or loosening, peri-implant fracture, acromion osteolysis, postoperative acromioclavicular joint arthrosis, non-union, or delayed union, were also analyzed. Results: There were no differences in the clinical outcomes (ASES, KSS, and Constant scores) between the two groups. Bone union was achieved in a significantly shorter period in the hybrid hook LCP group (13.6 +/- 2.0 weeks) than in the AO hook LCP group (17.5 +/- 4.8 weeks, p < 0.001). Consequently, the time to implant removal was also significantly shorter in the hybrid hook LCP group (4.0 +/- 0.5 months) than in the AO hook LCP group (5.4 +/- 1.1 months, p < 0.001). The MCCD% showed no significant differences between the treatment groups. There was no statistically significant difference in the complication rate between the two groups; however, the hybrid hook LCP fixation resulted in a lower prevalence of hook-related complications. Conclusion: The hybrid hook LCP fixation showed satisfactory clinical and radiologic outcomes in comparison with the AO hook LCP fixation. The hybrid hook LCP is useful for multiple screw fixation of inferior comminuted fragments in Neer type V distal clavicle fractures. The bone union was significantly shorter; thus, the time to implant removal was also significantly shorter. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 25 条
  • [1] [Anonymous], [No title captured]
  • [2] Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
    Beirer, Marc
    Siebenlist, Sebastian
    Croenlein, Moritz
    Postl, Lukas
    Huber-Wagner, Stefan
    Biberthaler, Peter
    Kirchhoff, Chlodwig
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [3] Biomechanical Comparison of Arthroscopic Repairs for Acromioclavicular Joint Instability Suture Button Systems Without Biological Augmentation
    Beitzel, Knut
    Obopilwe, Elifho
    Chowaniec, David M.
    Niver, Genghis E.
    Nowak, Michael D.
    Hanypsiak, Bryan T.
    Guerra, James J.
    Arciero, Robert A.
    Mazzocca, Augustus D.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10) : 2218 - 2225
  • [4] Modified tension band fixation and coracoclavicular stabilisation for unstable distal clavicle fracture
    Choi, Sungwook
    Kim, Sang-Rim
    Kang, Hyunseong
    Kim, Donghee
    Park, Yong-Geun
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (02): : 259 - 264
  • [5] DEAFENBAUGH M K, 1990, Contemporary Orthopaedics, V20, P405
  • [6] Rare complication of clavicular hook plate: clavicle fracture at the medial end of the plate
    Ding, Muliang
    Ni, Jiangdong
    Hu, Jianzhong
    Song, Deye
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (07) : E18 - E20
  • [7] Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures
    Erdle, Benjamin
    Izadpanah, Kaywan
    Jaeger, Martin
    Jensen, Patrizia
    Konstantinidis, Lukas
    Zwingmann, Joern
    Suedkamp, Norbert P.
    Maier, Dirk
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (05) : 651 - 662
  • [8] Angular stable fixation of displaced distal-third clavicle fractures with superior precontoured locking plates
    Fleming, Mark A.
    Dachs, Robert
    Maqungo, Sithombo
    du Plessis, Jean-Pierre
    Vrettos, Basil C.
    Roche, Stephen J. L.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (05) : 700 - 704
  • [9] Treatment of distal clavicle fracture using Kirschner wires and tension-band wires
    Kao, FC
    Chao, EK
    Chen, CH
    Yu, SW
    Chen, CY
    Yen, CY
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (03): : 522 - 525
  • [10] Kim Kyung-Yong, 2016, [Journal of the Korean Fracture Society, 대한골절학회지], V29, P55