Hancock II Bioprosthesis for Aortic Valve Replacement: The Gold Standard of Bioprosthetic Valves Durability?

被引:164
作者
David, Tirone E.
Armstrong, Susan
Maganti, Manjula
机构
[1] Toronto Gen Hosp, Peter Munk Cardiac Ctr, Div Cardiovasc Surg, Toronto, ON, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
PERICARDIAL BIOPROSTHESIS; EXPERIENCE; PERFORMANCE; OUTCOMES;
D O I
10.1016/j.athoracsur.2010.05.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. This study examined the long-term durability of the Hancock II bioprosthesis (Medtronic, Minneapolis, MN) in the aortic position. Methods. From 1982 to 2004, 1134 patients underwent aortic valve replacement (AVR) with Hancock II bioprosthesis and were prospectively monitored. Mean patient age was 67 +/- 11 years; 202 patients were younger than 60, 402 were 60 to 70, and 526 were older than 70. Median follow-up was 12.2 years and 99.2% complete. Valve function was assessed in 94% of patients. Freedom from adverse events was estimated by the Kaplan-Meier method. Results. Survival at 20 and 25 years was 19.2% +/- 2% and 6.7% +/- 2.8%, respectively, with only 34 and 3 patients at risk. Survival at 20 years was 54.9% +/- 6.4% in patients younger than 60 years, 22.7% +/- 3.3% in those 60 to 70, and 2.4% +/- 1.9% in those older than 70 (p = 0.01). Structural valve deterioration developed in 67 patients aged younger than 60, in 18 patients aged 60 to 70, and in 2 patients older than 70. The freedom from structural valve deterioration at 20 years was 63.4% +/- 4.2% in the entire cohort, 29.2% +/- 5.7% in patients younger than 60 years, 85.2% +/- 3.7% in patients aged 60 to 70, and 99.8% +/- 0.2% in patients older than 70 (truncated at 18 years). Repeat AVR was performed in 104 patients (74 for structural valve failure, 16 for endocarditis, and 14 for other reasons). At 20 years, the overall freedom from AVR was 65.1% +/- 4% for any reason, 29.8% +/- 5.4% in patients younger than 60 years, 86.8% +/- 3.3% in patients 60 to 70, and 98.3% +/- 0.6% in patients older than 70. Conclusions: Hancock II bioprosthesis is a very durable valve in patients 60 years and older and is probably the gold standard of bioprosthetic valve durability in this patient population. (Ann Thorac Surg 2010; 90: 775-81) (C) 2010 by The Society of Thoracic Surgeons
引用
收藏
页码:775 / 781
页数:7
相关论文
共 50 条
  • [41] Late haemodynamic performance and survival after aortic valve replacement with the Mosaic bioprosthesis
    Glaser, Natalie
    Franco-Cereceda, Anders
    Sartipy, Ulrik
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (05) : 756 - 762
  • [42] Failing stentless aortic valves: redo aortic root replacement or valve in a valve?
    Finch, Jonathan
    Roussin, Isabelle
    Pepper, John
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (03) : 495 - 504
  • [43] Transcatheter Aortic and Mitral Valve Implantations for Failed Bioprosthetic Heart Valves
    Dvir, Danny
    Assali, Abid
    Vaknin-Assa, Hana
    Sagie, Alexander
    Shapira, Yaron
    Porat, Eyal
    Kornowski, Ran
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (09) : 377 - 381
  • [44] Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves
    Sarkar, Kunal
    Sardella, Gennaro
    Romeo, Francesco
    De Benedictis, Mauro
    Tarsia, Giandomenico
    Iadanza, Alessandro
    Sharma, Samin. K.
    Barbanti, Marco
    Tamburino, Corrado
    Ussia, Gian Paolo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 864 - 870
  • [45] Transcatheter aortic valve replacement in patients with bicuspid aortic valves
    Patel, Amisha
    Leon, Martin B.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S3568 - S3572
  • [46] Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement
    Chakravarty, Tarun
    Patel, Akshar
    Kapadia, Samir
    Raschpichler, Matthias
    Smalling, Richard W.
    Szeto, Wilson Y.
    Abramowitz, Yigal
    Cheng, Wen
    Douglas, Pamela S.
    Hahn, Rebecca T.
    Herrmann, Howard C.
    Kereiakes, Dean
    Svensson, Lars
    Yoon, Sung-Han
    Babaliaros, Vasilis C.
    Kodali, Susheel
    Thourani, Vinod H.
    Alu, Maria C.
    Liu, Yangbo
    McAndrew, Thomas
    Mack, Michael
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (09) : 1190 - 1200
  • [47] Long-Term Functional and Structural Durability of Bioprosthetic Valves Placed in the Aortic Valve Position via Percutaneous Rout in Israel
    Orvin, Katia
    Ben Zekry, Sagit
    Morelli, Olga
    Barabash, Israel M.
    Segev, Amit
    Danenberg, Haim
    Assali, Abid
    Guetta, Victor
    Assa, Hana Vaknin
    Zeniou, Vicki
    Lotan, Chaim
    Sagie, Alexander
    Gilon, Dan
    Feinberg, Micha S.
    Shapira, Yaron
    Ran, Kornowski
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (11) : 1748 - 1756
  • [48] Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
    Mujtaba, Syed Saleem
    Ledingham, Simon M.
    Shah, Asif Raza
    Pillay, Thasee
    Schueler, Stephan
    Clark, Stephen
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 33 (02) : 122 - 128
  • [49] Pulmonary Valve Replacement Function in Adolescents: A Comparison of Bioprosthetic Valves and Homograft Conduits
    Batlivala, Sarosh P.
    Emani, Sitaram
    Mayer, John E.
    McElhinney, Doff B.
    ANNALS OF THORACIC SURGERY, 2012, 93 (06) : 2007 - 2016
  • [50] Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis
    Ntinopoulos, Vasileios
    Biefer, Hector Rodriguez Cetina
    Dushaj, Stak
    Rings, Laura
    Fleckenstein, Philine
    Dzemali, Omer
    Haeussler, Achim
    THORACIC AND CARDIOVASCULAR SURGEON, 2024, 72 (03) : 197 - 204