Method for determination of acephate, methamidophos, omethoate, dimethoate, ethylenethiourea and propylenethiourea in human urine using high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry

被引:41
作者
Montesano, M. Angela
Olsson, Anders O.
Kuklenyik, Peter
Needham, Larry L.
Bradman, Asa
Barr, Dana B.
机构
[1] Ctr Dis Control & Prevent, Atlanta, GA 30341 USA
[2] Univ Calif Berkeley, Sch Publ Hlth, Ctr Childrens Environm Hlth Res, Berkeley, CA 94720 USA
关键词
organophosphorus insecticides; bisdithiocarbamates; ETU; acephate; methamidophos; urine;
D O I
10.1038/sj.jes.7500550
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Because of increasing concern about widespread use of insecticides and fungicides, we have developed a highly sensitive analytical method to quantify urine-specific urinary biomarkers of the organophosphorus pesticides acephate, methamidophos, omethoate, dimethoate, and two metabolites from the fungicides alkylenebis-(dithiocarbamate) family: ethylenethiourea and propylenethiourea. The general sample preparation included lyophilization of the urine samples followed by extraction with dichloromethane. The analytical separation was performed by high-performance liquid chromatography (HPLC), and detection by a triple quadrupole mass spectrometer with and atmospheric pressure chemical ionization source in positive ion mode using multiple reaction monitoring and tandem mass spectrometry (MS/MS) analysis. Two different Thermo-Finnigan (San Jose, CA, USA) triple quadrupole mass spectrometers, a TSQ 7000 and a TSQ Quantum Ultra, were used in these analyses; results are presented comparing the method specifications of these two instruments. Isotopically labeled internal standards were used for three of the analytes. The use of labeled internal standards in combination with HPLC-MS/MS provided a high degree of selectivity and precision. Repeated analysis of urine samples spiked with high, medium and low concentration of the analytes gave relative standard deviations of less than 18%. For all compounds the extraction efficiency ranged between 52% and 63%, relative recoveries were about 100%, and the limits of detection were in the range of 0.001-0.282 ng/ml.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 40 条
[1]   Multiresidue method for the analysis of multiclass pesticides in agricultural products by gas chromatography-tandem mass spectrometry [J].
Agüera, A ;
Contreras, M ;
Crespo, J ;
Fernández-Alba, AR .
ANALYST, 2002, 127 (03) :347-354
[2]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[3]  
[Anonymous], 1987, Quality Assurance of Chemical Measurements
[4]  
[Anonymous], 2002, BASIC QC PRACTICES T
[5]   Biological monitoring of pesticide exposure: a review of analytical methods [J].
Aprea, C ;
Colosio, C ;
Mammone, T ;
Minoia, C ;
Maroni, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02) :191-219
[6]  
Aprea C, 1998, J TOXICOL ENV HEAL A, V53, P263, DOI 10.1080/009841098159277
[7]   High-performance liquid chromatography-tandem mass spectrometry method for quantifying sulfonylurea herbicides in human urine: reconsidering the validation process [J].
Baker, SE ;
Olsson, AO ;
Needham, LL ;
Barr, DB .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (06) :963-976
[8]   Analytical methods for biological monitoring of exposure to pesticides: a review [J].
Barr, DB ;
Needham, LL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2) :5-29
[9]   A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry [J].
Barr, DB ;
Barr, JR ;
Maggio, VL ;
Whitehead, RD ;
Sadowski, MA ;
Whyatt, RM ;
Needham, LL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2) :99-111
[10]   Determination of dithiocarbamates and metabolites in plants by liquid chromatography-mass spectrometry [J].
Blasco, C ;
Font, G ;
Picó, Y .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (02) :267-276