Wingspan Stents for the Treatment of Symptomatic Atherosclerotic Stenosis in Small Intracranial Vessels: Safety and Efficacy Evaluation

被引:25
作者
Zhang, L. [1 ]
Huang, Q. [1 ]
Zhang, Y. [1 ]
Liu, J. [1 ]
Hong, B. [1 ]
Xu, Y. [1 ]
Zhao, W. [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Neurosurg, Shanghai, Peoples R China
关键词
SELF-EXPANDING STENTS; BALLOON ANGIOPLASTY; ASSISTED ANGIOPLASTY; DISEASE; METAANALYSIS; LESION; SYSTEM;
D O I
10.3174/ajnr.A2772
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Until now, endovascular treatment of symptomatic atherosclerotic stenosis in small intracranial arteries (<= 2.5 mm) was limited. We evaluated the safety and efficacy of the treatment by using Wingspan scents in arteries of this caliber. MATERIALS AND METHODS: From March 2007 to July 2010, 53 symptomatic intracranial stenoses,with narrowing of at least 50% in 53 patients were treated by using Wingspan stents. Clinical manifestations and imaging features were recorded. RESULTS: The technical success rate was 98.1%. There were no serious complications, with the exception of 1 patient who experienced a small cerebral hemorrhage caused by perforation of microwire. Thirty-nine patients (74%) were available for follow-up imaging with DSA. ISR was documented in 13 of these patients, including 2 patients with symptomatic ISR. The median length of the vascular lesions was 5.39 mm, and patients whose vascular lesions were longer than 5.39 mm had a much higher incidence of ISR than patients whose vascular lesions were shorter than 5.39 mm (53% versus 15%, respectively). The median ratio of the reference artery diameter to the stent diameter was 0.78, and patients whose ratio was smaller than 0.78 had a much higher incidence of ISR than patients whose ratio was larger than 0.78 153% versus 15%, respectively). CONCLUSIONS: In our series, percutaneous transluminal angioplasty and stent placement of small intracranial arteries by using Wingspan stents was safe. The ISR rate was relatively high; most patients having ISR were asymptomatic. Further follow-up is needed to assess the long-term efficacy of this procedure.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 29 条
[1]   Is bare-metal stenting superior to balloon angioplasty for small vessel coronary artery disease? Evidence from a meta-analysis of randomized trials [J].
Agostoni, P ;
Biondi-Zoccai, GGL ;
Gasparini, GL ;
Anselmi, M ;
Morando, G ;
Turri, M ;
Abbate, A ;
McFadden, EP ;
Vassanelli, C ;
Zardini, P ;
Colombo, A ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 2005, 26 (09) :881-889
[2]   Angiographic patterns of Wingspan in-stent restenosis [J].
Albuquerque, Felipe C. ;
Levy, Elad I. ;
Turk, Aquilla S. ;
Niemann, David B. ;
Aagaard-Kienitz, Beverly ;
Pride, G. Lee, Jr. ;
Purdy, Phillip D. ;
Welch, Babu C. ;
Woo, Henry H. ;
Rasmussen, Peter A. ;
Hopkins, L. Nelson ;
Masaryk, Thomas J. ;
McDougall, Cameron G. ;
Fiorella, David J. .
NEUROSURGERY, 2008, 63 (01) :23-27
[3]   A novel, self-expanding, nitinol stent in medically refractory intracranial atherosclerotic stenoses - The Wingspan study [J].
Bose, Arani ;
Hartmann, Marius ;
Henkes, Hans ;
Liu, Hon Man ;
Teng, Michael M. H. ;
Szikora, Istvan ;
Berlis, Ansgar ;
Reul, Jurgen ;
Yu, Simon C. H. ;
Forsting, Michael ;
Lui, Matt ;
Lim, Winston ;
Sit, Siu Po .
STROKE, 2007, 38 (05) :1531-1537
[4]   Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis [J].
Chen, Henry Y. ;
Hermiller, James ;
Sinha, Anjan K. ;
Sturek, Michael ;
Zhu, Luoding ;
Kassab, Ghassan S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (05) :1686-1691
[5]  
Chow MM, 2005, AM J NEURORADIOL, V26, P869
[6]  
Cosottini M, 2010, STROKE RES TREAT, V14, P2010
[7]   Anatomical and physiologic assessments in patients with small coronary artery disease: Final results of the Physiologic and Anatomical Evaluation Prior to and After Stent Implantation in Small Coronary Vessels (PHANTOM) trial [J].
Costa, Marco A. ;
Sabate, Manel ;
Staico, Rodolfo ;
Alfonso, Fernando ;
Seixas, Ana C. ;
Albertal, Mariano ;
Crossman, Arthur ;
Angiolillo, Dominick J. ;
Zenni, Martin ;
Sousa, J. Eduardo ;
Macaya, Carlos ;
Bass, Theodore A. .
AMERICAN HEART JOURNAL, 2007, 153 (02) :296.e1-296.e7
[8]  
Elezi S, 1999, CATHETER CARDIO INTE, V48, P151, DOI 10.1002/(SICI)1522-726X(199910)48:2<151::AID-CCD6>3.0.CO
[9]  
2-C
[10]   Vessel size and long-term outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Neumann, FJ ;
Hadamitzky, M ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 1998, 98 (18) :1875-1880