The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure

被引:84
|
作者
Tjong, Willy [1 ]
Kazakia, Galateia J. [1 ]
Burghardt, Andrew J. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
关键词
HR-pQCT; micro-CT; resolution; trabecular bone; cortical bone; DISTAL RADIUS; POSTMENOPAUSAL WOMEN; POROSITY; DENSITY; MICROARCHITECTURE; THICKNESS; ACCURACY; PLATES; TIBIA;
D O I
10.1118/1.3689813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate quantification of bone microstructure plays a significant role in understanding bone mechanics and response to disease or treatment. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for the quantification of trabecular and cortical structure in vivo, with the capability of generating images at multiple voxel sizes (41, 82, and 123 mu m). The aim of this study was to characterize the effect of voxel size on structural measures of trabecular and cortical bone and to determine accuracy in reference to micro-CT (mCT), the gold standard for bone microstructure quantification. Methods: Seventeen radii from human cadaver specimens were imaged at each HR-pQCT voxel size and subsequently imaged using mu CT. Bone density and microstructural assessment was performed in both the trabecular and cortical compartments, including cortical porosity quantification. Two distinct analysis techniques were applied to the 41 mu m HR-pQCT data: the standard clinical indirect analysis and a direct analysis requiring no density or structural model assumptions. Analysis parameters were adjusted to enable segmentation and structure extraction at each voxel size. Results: For trabecular microstructural measures, the 41 mu m HR-pQCT data displayed the strongest correlations and smallest errors compared to mu CT data. The direct analysis technique applied to the 41 mu m data yielded an additional improvement in accuracy, especially for measures of trabecular thickness. The 123 mu m data performed poorly, with all microstructural measures either having moderate or nonsignificant correlations with mu CT data. Trabecular densitometric measures showed strong correlations to mu CT data across all voxel sizes. Cortical thickness was strongly correlated with mu CT values across all HR-pQCT voxel sizes. The accuracy of cortical porosity parameters was highly dependent on voxel size; again, the 41 mu m data was most strongly correlated. Measures of cortical density and pore diameter at all HR-pQCT voxel sizes had either weak or nonsignificant correlations. Conclusions: This study demonstrates the effect of voxel size on the accuracy of HR-pQCT measurements of trabecular and cortical microstructure and presents parameters for HR-pQCT analysis at nonstandard resolutions. For all parameters measured, correlations were strongest at 41 mu m. Weak correlations for porosity measures indicate that a better understanding of pore structure and resolution dependence is needed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3689813]
引用
收藏
页码:1893 / 1903
页数:11
相关论文
共 50 条
  • [41] Cortical and trabecular bone at the radius and tibia in postmenopausal breast cancer patients: A Peripheral Quantitative Computed Tomography (pQCT) study
    Szabo, K. A.
    Webber, C. E.
    Adachi, J. D.
    Tozer, R.
    Gordon, C.
    Papaioannou, A.
    BONE, 2011, 48 (02) : 218 - 224
  • [42] High-resolution peripheral quantitative computed tomography: research or clinical practice?
    Gazzotti, Silvia
    Aparisi Gomez, Maria Pilar
    Schileo, Enrico
    Taddei, Fulvia
    Sangiorgi, Luca
    Fusaro, Maria
    Miceli, Marco
    Guglielmi, Giuseppe
    Bazzocchi, Alberto
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1150)
  • [43] Bone microstructure of adult patients with non-surgical hypoparathyroidism assessed by high-resolution peripheral quantitative computed tomography
    J. Liu
    S. Chen
    T. Quan
    Y. Wang
    O. Wang
    M. Nie
    Y. Jiang
    M. Li
    X. Xing
    W. Xia
    Osteoporosis International, 2020, 31 : 2219 - 2230
  • [44] Consequences of Hyperthyroidism and Its Treatment for Bone Microarchitecture Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Nicolaisen, Pia
    Obling, Maria Lohman
    Winther, Kristian Hillert
    Hansen, Stinus
    Hermann, Anne Pernille
    Hegedus, Laszlo
    Bonnema, Steen Joop
    Brix, Thomas Heiberg
    THYROID, 2021, 31 (02) : 208 - 216
  • [45] Bone-GAN: Generation of virtual bone microstructure of high resolution peripheral quantitative computed tomography
    Thomsen, Felix S. L.
    Iarussi, Emmanuel
    Borggrefe, Jan
    Boyd, Steven K.
    Wang, Yue
    Battie, Michele C.
    MEDICAL PHYSICS, 2023, 50 (11) : 6943 - 6954
  • [46] A new method of segmentation of compact-appearing, transitional and trabecular compartments and quantification of cortical porosity from high resolution peripheral quantitative computed tomographic images
    Zebaze, R.
    Ghasem-Zadeh, A.
    Mbala, A.
    Seeman, E.
    BONE, 2013, 54 (01) : 8 - 20
  • [47] IN VIVO MEASUREMENTS OF CORTICAL THICKNESS AND POROSITY AT THE PROXIMAL THIRD OF THE TIBIA USING GUIDED WAVES: COMPARISON WITH SITE-MATCHED PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND DISTAL HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY
    Schneider, Johannes
    Ramiandrisoa, Donatien
    Armbrecht, Gabriele
    Ritter, Zully
    Felsenberg, Dieter
    Raum, Kay
    Minonzio, Jean-Gabriel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05) : 1234 - 1242
  • [48] Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone
    C. de Charry
    S. Boutroy
    R. Ellouz
    F. Duboeuf
    R. Chapurlat
    H. Follet
    J. B. Pialat
    Osteoporosis International, 2016, 27 : 3073 - 3082
  • [49] High-resolution peripheral QCT imaging of bone micro-structure in adolescents
    Burrows, M.
    Liu, D.
    McKay, H.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 (03) : 515 - 520
  • [50] Can high-resolution peripheral quantitative computed tomography imaging of subchondral and cortical bone predict condylar fracture in Thoroughbred racehorses?
    Trope, G. D.
    Ghasem-Zadeh, A.
    Anderson, G. A.
    Mackie, E. J.
    Whitton, R. C.
    EQUINE VETERINARY JOURNAL, 2015, 47 (04) : 428 - 432