The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure

被引:84
|
作者
Tjong, Willy [1 ]
Kazakia, Galateia J. [1 ]
Burghardt, Andrew J. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
关键词
HR-pQCT; micro-CT; resolution; trabecular bone; cortical bone; DISTAL RADIUS; POSTMENOPAUSAL WOMEN; POROSITY; DENSITY; MICROARCHITECTURE; THICKNESS; ACCURACY; PLATES; TIBIA;
D O I
10.1118/1.3689813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate quantification of bone microstructure plays a significant role in understanding bone mechanics and response to disease or treatment. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for the quantification of trabecular and cortical structure in vivo, with the capability of generating images at multiple voxel sizes (41, 82, and 123 mu m). The aim of this study was to characterize the effect of voxel size on structural measures of trabecular and cortical bone and to determine accuracy in reference to micro-CT (mCT), the gold standard for bone microstructure quantification. Methods: Seventeen radii from human cadaver specimens were imaged at each HR-pQCT voxel size and subsequently imaged using mu CT. Bone density and microstructural assessment was performed in both the trabecular and cortical compartments, including cortical porosity quantification. Two distinct analysis techniques were applied to the 41 mu m HR-pQCT data: the standard clinical indirect analysis and a direct analysis requiring no density or structural model assumptions. Analysis parameters were adjusted to enable segmentation and structure extraction at each voxel size. Results: For trabecular microstructural measures, the 41 mu m HR-pQCT data displayed the strongest correlations and smallest errors compared to mu CT data. The direct analysis technique applied to the 41 mu m data yielded an additional improvement in accuracy, especially for measures of trabecular thickness. The 123 mu m data performed poorly, with all microstructural measures either having moderate or nonsignificant correlations with mu CT data. Trabecular densitometric measures showed strong correlations to mu CT data across all voxel sizes. Cortical thickness was strongly correlated with mu CT values across all HR-pQCT voxel sizes. The accuracy of cortical porosity parameters was highly dependent on voxel size; again, the 41 mu m data was most strongly correlated. Measures of cortical density and pore diameter at all HR-pQCT voxel sizes had either weak or nonsignificant correlations. Conclusions: This study demonstrates the effect of voxel size on the accuracy of HR-pQCT measurements of trabecular and cortical microstructure and presents parameters for HR-pQCT analysis at nonstandard resolutions. For all parameters measured, correlations were strongest at 41 mu m. Weak correlations for porosity measures indicate that a better understanding of pore structure and resolution dependence is needed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3689813]
引用
收藏
页码:1893 / 1903
页数:11
相关论文
共 50 条
  • [31] Accurate and Efficient Plate and Rod Microfinite Element Models for Whole Bone Segments Based on High-Resolution Peripheral Computed Tomography
    Wang, Ji
    Zhou, Bin
    Hu, Yizhong Jenny
    Zhang, Zhendong
    Yu, Y. Eric
    Nawathe, Shashank
    Nishiyama, Kyle K.
    Keaveny, Tony M.
    Shane, Elizabeth
    Guo, X. Edward
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (04):
  • [32] Lower leg arterial calcification assessed by high-resolution peripheral quantitative computed tomography is associated with bone microstructure abnormalities in women
    Paccou, J.
    Edwards, M. H.
    Patsch, J. M.
    Jameson, K. A.
    Ward, K. A.
    Moss, C.
    Dennison, E. M.
    Cooper, C.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 (11) : 3279 - 3287
  • [33] A local adaptive threshold strategy for high resolution peripheral quantitative computed tomography of trabecular bone
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Majumdar, Sharmila
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (10) : 1678 - 1686
  • [34] A Local Adaptive Threshold Strategy for High Resolution Peripheral Quantitative Computed Tomography of Trabecular Bone
    Andrew J. Burghardt
    Galateia J. Kazakia
    Sharmila Majumdar
    Annals of Biomedical Engineering, 2007, 35 : 1678 - 1686
  • [35] Recommendations for High-resolution Peripheral Quantitative Computed Tomography Assessment of Bone Density, Microarchitecture, and Strength in Pediatric Populations
    Gabel, L.
    Kent, K.
    Hosseinitabatabaei, S.
    Burghardt, A. J.
    Leonard, M. B.
    Rauch, F.
    Willie, B. M.
    CURRENT OSTEOPOROSIS REPORTS, 2023, 21 (05) : 609 - 623
  • [36] High-Resolution Peripheral Quantitative CT Imaging: Cortical Porosity, Poor Trabecular Bone Microarchitecture, and Low Bone Strength in Lung Transplant Recipients
    Fischer, Lukas
    Valentinitsch, Alexander
    DiFranco, Matthew D.
    Schueller-Weidekamm, Claudia
    Kienzl, Daniela
    Resch, Heinrich
    Gross, Thomas
    Weber, Michael
    Jaksch, Peter
    Klepetko, Walter
    Zweytick, Barbara
    Pietschmann, Peter
    Kainberger, Franz
    Langs, Georg
    Patsch, Janina M.
    RADIOLOGY, 2015, 274 (02) : 473 - 481
  • [37] Precision of bone mechanoregulation assessment in humans using longitudinal high-resolution peripheral quantitative computed tomography in vivo
    Walle, Matthias
    Whittier, Danielle E.
    Schenk, Denis
    Atkins, Penny R.
    Blauth, Michael
    Zysset, Philippe
    Lippuner, Kurt
    Mueller, Ralph
    Collins, Caitlyn J.
    BONE, 2023, 172
  • [38] Prevalence of vitamin D insufficiency among adolescents and its correlation with bone parameters using high-resolution peripheral quantitative computed tomography
    Cheung, T. F.
    Cheuk, K. Y.
    Yu, F. W. P.
    Hung, V. W. Y.
    Ho, C. S.
    Zhu, T. Y.
    Ng, B. K. W.
    Lee, K. M.
    Qin, L.
    Ho, S. S. Y.
    Wong, G. W. K.
    Cheng, J. C. Y.
    Lam, T. P.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 (08) : 2477 - 2488
  • [39] In vivo analysis of subchondral trabecular bone in patients with osteoarthritis of the knee using second-generation high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Shiraishi, Kazuteru
    Chiba, Ko
    Okazaki, Narihiro
    Yokota, Kazuaki
    Nakazoe, Yusuke
    Kidera, Kenichi
    Yonekura, Akihiko
    Tomita, Masato
    Osaki, Makoto
    BONE, 2020, 132
  • [40] Bone structural and mechanical indices in Adolescent Idiopathic Scoliosis evaluated by high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Yu, Wing Sze
    Chan, Ka Yan
    Yu, Fiona Wai Ping
    Ng, Bobby Kin Wah
    Lee, Kwong Man
    Qin, Ling
    Lam, Tsz Ping
    Cheng, Jack Chun Yiu
    BONE, 2014, 61 : 109 - 115