The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure

被引:84
|
作者
Tjong, Willy [1 ]
Kazakia, Galateia J. [1 ]
Burghardt, Andrew J. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
关键词
HR-pQCT; micro-CT; resolution; trabecular bone; cortical bone; DISTAL RADIUS; POSTMENOPAUSAL WOMEN; POROSITY; DENSITY; MICROARCHITECTURE; THICKNESS; ACCURACY; PLATES; TIBIA;
D O I
10.1118/1.3689813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate quantification of bone microstructure plays a significant role in understanding bone mechanics and response to disease or treatment. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for the quantification of trabecular and cortical structure in vivo, with the capability of generating images at multiple voxel sizes (41, 82, and 123 mu m). The aim of this study was to characterize the effect of voxel size on structural measures of trabecular and cortical bone and to determine accuracy in reference to micro-CT (mCT), the gold standard for bone microstructure quantification. Methods: Seventeen radii from human cadaver specimens were imaged at each HR-pQCT voxel size and subsequently imaged using mu CT. Bone density and microstructural assessment was performed in both the trabecular and cortical compartments, including cortical porosity quantification. Two distinct analysis techniques were applied to the 41 mu m HR-pQCT data: the standard clinical indirect analysis and a direct analysis requiring no density or structural model assumptions. Analysis parameters were adjusted to enable segmentation and structure extraction at each voxel size. Results: For trabecular microstructural measures, the 41 mu m HR-pQCT data displayed the strongest correlations and smallest errors compared to mu CT data. The direct analysis technique applied to the 41 mu m data yielded an additional improvement in accuracy, especially for measures of trabecular thickness. The 123 mu m data performed poorly, with all microstructural measures either having moderate or nonsignificant correlations with mu CT data. Trabecular densitometric measures showed strong correlations to mu CT data across all voxel sizes. Cortical thickness was strongly correlated with mu CT values across all HR-pQCT voxel sizes. The accuracy of cortical porosity parameters was highly dependent on voxel size; again, the 41 mu m data was most strongly correlated. Measures of cortical density and pore diameter at all HR-pQCT voxel sizes had either weak or nonsignificant correlations. Conclusions: This study demonstrates the effect of voxel size on the accuracy of HR-pQCT measurements of trabecular and cortical microstructure and presents parameters for HR-pQCT analysis at nonstandard resolutions. For all parameters measured, correlations were strongest at 41 mu m. Weak correlations for porosity measures indicate that a better understanding of pore structure and resolution dependence is needed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3689813]
引用
收藏
页码:1893 / 1903
页数:11
相关论文
共 50 条
  • [21] A New High-Resolution Computed Tomography (CT) Segmentation Method for Trabecular Bone Architectural Analysis
    Scherf, Heike
    Tilgner, Rico
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2009, 140 (01) : 39 - 51
  • [22] High resolution peripheral quantitative computed tomography for the assessment of morphological and mechanical bone parameters
    Fuller, Henrique
    Fuller, Ricardo
    Pereira, Rosa Maria R.
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2015, 55 (04) : 352 - 362
  • [23] Cortical bone density and thickness alterations by high-resolution peripheral quantitative computed tomography: association with vertebral fractures in primary Sjogren's syndrome
    Pasoto, Sandra G.
    Augusto, Kristopherson L.
    Alvarenga, Jackeline C.
    Takayama, Liliam
    Oliveira, Ricardo M.
    Bonfa, Eloisa
    Pereira, Rosa M. R.
    RHEUMATOLOGY, 2016, 55 (12) : 2200 - 2211
  • [24] Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
    Whittier, D. E.
    Boyd, S. K.
    Burghardt, A. J.
    Paccou, J.
    Ghasem-Zadeh, A.
    Chapurlat, R.
    Engelke, K.
    Bouxsein, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (09) : 1607 - 1627
  • [25] Repair of Bone Erosion in Rheumatoid Arthritis by Denosumab: A High-Resolution Peripheral Quantitative Computed Tomography Study
    Yue, Jiang
    Griffith, James F.
    Xiao, Fan
    Shi, Lin
    Wang, Defeng
    Shen, Jiayun
    Wong, Priscilla
    Li, Edmund K.
    Li, Martin
    Li, Tena K.
    Zhu, Tracy Y.
    Hung, Vivian W.
    Qin, Ling
    Tam, Lai-Shan
    ARTHRITIS CARE & RESEARCH, 2017, 69 (08) : 1156 - 1163
  • [26] High-Resolution Peripheral Quantitative Computed Tomography for Bone Evaluation in Inflammatory Rheumatic Disease
    Klose-Jensen, Rasmus
    Tse, Justin J.
    Keller, Kresten Krarup
    Barnabe, Cheryl
    Burghardt, Andrew J.
    Finzel, Stephanie
    Tam, Lai-Shan
    Hauge, Ellen-Margrethe
    Stok, Kathryn S.
    Manske, Sarah L.
    FRONTIERS IN MEDICINE, 2020, 7
  • [27] Assessment of Trabecular Bone During Dental Implant Planning using Cone beam Computed Tomography with High-resolution Parameters
    Bohner, Lauren
    Tortamano, Pedro
    Gremse, Felix
    Chilvarquer, Israel
    Kleinheinz, Johannes
    Hanisch, Marcel
    OPEN DENTISTRY JOURNAL, 2021, 15 : 57 - 63
  • [28] Bone Evaluation by High-Resolution Peripheral Quantitative Computed Tomography in Patients With Adrenal Incidentaloma
    Moraes, Aline Barbosa
    de Paula, Marcela Pessoa
    Paranhos-Neto, Francisco de Paula
    Ribeiro Cavalari, Emanuela Mello
    Cordeiro de Morais, Felipe Fernandes
    Carvalho Curi, Daniel Silva
    Cardoso Lima, Luis Felipe
    Carvalho de Mendonca, Laura Maria
    Fleiuss Farias, Maria Lucia
    Madeira, Miguel
    Vieira Neto, Leonardo
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (08) : E2726 - E2737
  • [29] Assessing bone impairment in ankylosing spondylitis (AS) using the trabecular bone score (TBS) and high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Caparbo, Valeria F.
    Furlam, Pedro
    Saad, Carla G. S.
    Alvarenga, Jackeline C.
    Aubry-Rozier, Berengere
    Hans, Didier
    de Brum-Fernandes, Artur J.
    Pereira, Rosa M. R.
    BONE, 2019, 122 : 8 - 13
  • [30] Precision of High-Resolution Peripheral Quantitative Computed Tomography Measurement Variables: Influence of Gender, Examination Site, and Age