Study on the use of boromycin as a chiral selector in capillary electrophoresis

被引:30
|
作者
Maier, Vitezslav [1 ]
Ranc, Vaclav [2 ]
Svidrnoch, Martin [2 ]
Petr, Jan [1 ]
Sevcik, Juraj [2 ]
Tesarova, Eva [3 ]
Armstrong, Daniel W. [4 ]
机构
[1] Palacky Univ, Reg Ctr Adv Mat & Technol, Dept Analyt Chem, Fac Sci, CZ-77146 Olomouc, Czech Republic
[2] Palacky Univ, Dept Analyt Chem, Fac Sci, CZ-77146 Olomouc, Czech Republic
[3] Charles Univ Prague, Dept Phys & Macromol Chem, Fac Sci, Prague 12843 2, Czech Republic
[4] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
关键词
Boromycin; Non-aqueous capillary electrophoresis; Chiral separation; Chiral selector; ENANTIOMERIC SEPARATIONS; MACROCYCLIC ANTIBIOTICS; ENANTIOSEPARATIONS;
D O I
10.1016/j.chroma.2012.02.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The first application of boromycin as a chiral selector in capillary electrophoresis is described. Given boromycin's insolubility in water, a non-aqueous background electrolyte based on methanol was used for enantiomeric discrimination of selected chiral primary amines (alpha-methylbenzylamine,R,S-tryptophanol, R,S-norepinephrine. R,S-octopamine, R,S-p-hydroxynorephedrine and R,S-2-amino-1-phenylethanol). A basic study of experimental conditions including the influence of boromycin concentration, the composition and concentration of background electrolyte and also the influence of different organic solvents was performed. The best separation condition was 75 mM Tris/50 mM boric acid in methanol. (s)(w)pH 9.0, with a positive separation voltage. The enantiomeric separation of the primary amines was achieved within 14 min with resolution values greater than 1.5 for the majority of the studied analytes. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [1] Use of Gamithromycin as a Chiral Selector in Capillary Electrophoresis
    Ren, Siru
    Zhang, Qi
    Xue, Song
    Liu, Siyao
    Rui, Mengjie
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624 (1624)
  • [2] USE OF BETA-CYCLODEXTRIN POLYMER AS A CHIRAL SELECTOR IN CAPILLARY ELECTROPHORESIS
    ATURKI, Z
    FANALI, S
    JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) : 137 - 146
  • [3] Evaluation of a new macrocyclic antibiotic as a chiral selector for use in capillary electrophoresis
    Sharp, VS
    Risley, DS
    McCarthy, S
    Huff, BE
    Strege, MA
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (06) : 887 - 898
  • [4] Evaluation of kasugamycin as a chiral selector in capillary electrophoresis
    Zhang, Chunyan
    Fan, Yifeng
    Cai, Liangliang
    Ma, Xiaofei
    ANALYST, 2023, 148 (06) : 1322 - 1329
  • [5] Choice of chiral selector for enantioseparation by capillary electrophoresis
    Blanco, M
    Valverde, I
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (07) : 428 - 439
  • [6] Azithromycin as a new chiral selector in capillary electrophoresis
    Kumar, Avvaru Praveen
    Park, Jung Hag
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (09) : 1314 - 1317
  • [7] Chiral separations by capillary zone electrophoresis with the use of cyanoethylated-β-cyclodextrin as chiral selector
    Aturki, Z
    Desiderio, C
    Mannina, L
    Fanali, S
    JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) : 91 - 104
  • [8] Doxycycline as a new chiral selector in capillary electrophoresis
    Jang, Min Gyeong
    Jang, Myung Duk
    Park, Jung Hag
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1508 : 176 - 181
  • [9] Chiral analysis by capillary electrophoresis using antibiotics as chiral selector
    Desiderio, C
    Fanali, S
    JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (01) : 37 - 56
  • [10] Enantiomeric resolution study by capillary electrophoresis - Selection of the appropriate chiral selector
    Fanali, S
    Desiderio, C
    Aturki, Z
    JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) : 185 - 194